District of Columbia licensing exam

District of Columbia Journeyman Plumber Exam: Practice Test & Licensing Guide

The PSI exam for the District of Columbia journeyman plumber license: 70 multiple-choice questions on the 2012 IPC, with plan reading the largest area. Open book, 3 hours.

Questions
70
Time limit
3 hours
Passing score
Not published by District of Columbia

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Plumbing Fixtures and Terminology

Which group of fixtures meets the 2012 IPC definition of a bathroom group when all are located together on the same floor level?

Requirements at a glance

AgencyD.C. Board of Industrial Trades, Department of Licensing and Consumer Protection (DLCP); exam by PSI
Exam70 multiple-choice questions, 3 hours (exam ID 302); Pass score not published; PSI reports PASS or FAIL
Experience4 years (8,000 work hours); a nationally certified apprenticeship can waive the exam (DLCP chart)
BooksOpen book: bound references only, permanent tabs, notes in ink or highlighting in code sections only; no writing during the exam
Fees$52 to PSI per exam; D.C. application and license fees are separate

Plumbers applying to the Board of Industrial Trades for a D.C. journeyman plumber license (plumbing only, no gas). The DLCP chart lists 4 years (8,000 work hours) of experience; a nationally certified apprenticeship can waive the exam.

How to get licensed, step by step

  1. Meet the experience requirement

    The DLCP chart lists 4 years (8,000 work hours) of experience, with tax records and an employment verification letter signed off by the master.

    D.C. Board of Industrial Trades (DLCP) (opens in a new tab)

  2. Apply to the District

    Submit the online application and fees to the Board of Industrial Trades. Approved candidates receive a notice of eligibility.

    D.C. online license application (opens in a new tab)

  3. Register with PSI

    Register by phone at (855) 557-0616 or online, giving the exam ID and title. Pay the $52 exam fee by credit or debit card when you book.

    Register with PSI: plumber exams (opens in a new tab)PSI: Washington D.C. Candidate Information Bulletin (8/25/2022) (opens in a new tab)

  4. Take the exam

    Bring your listed references and matching ID. You see PASS or FAIL right after the exam. To retest you must reapply with the District first.

    PSI: Washington D.C. Candidate Information Bulletin (8/25/2022) (opens in a new tab)

How to prepare

  • Plan reading is 27% of the exam; practice counting fixture units and sizing drains and vents from a drawing.
  • The PSI bulletin (8/25/2022) lists older editions than the District's adopted 2017 DC Construction Codes (2014 NEC, 2015 ICC codes). Confirm the current reference list with PSI (855-557-0616) or the DLCP before you buy books.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2012 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2012 International Plumbing Code (IPC), ICCEssential

    The edition on the PSI bulletin (8/25/2022). Confirm the current list with PSI or the DLCP.

    ICC (opens in a new tab)

Official reference list (as published by the testing agency)
  • 2012 International Plumbing Code (IPC)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Plumbing Fixtures and Terminology6
Plumbing Fundamentals14
Traps, Cleanouts, and Interceptors6
Special Requirements4
Drainage Requirements16
Vent Requirements16
Water Distribution11
Plan Reading27

The outline totals 100; the other items on the 70-question exam are unscored or unassigned.

Exam day details

  • Administered by PSI Services for the District of Columbia Board of Industrial Trades (DLCP).
  • Fee: $52 to PSI per computer-based exam. D.C. application and license fees are separate.
  • PSI exam ID 302: 70 multiple-choice questions, open book, 3 hours. The content outline is the PSI bulletin's.
  • The bulletin's plumbing references are the 2012 IPC (and the 2012 IFGC for the gas exams); the District's adopted construction codes are newer (2015 ICC codes). Confirm the current list with PSI or the DLCP.
  • The DLCP plumbing and gasfitting instructions say licenses expire March 31 of even-numbered years.
  • You apply to the Board online and pay the application fees first. Approved candidates get a notice of eligibility, then register with PSI at (855) 557-0616 or on PSI's D.C. pages using the exam ID and title.
  • Open book: bring only the references the bulletin lists. They must be bound (original, three-ring binder or stapled); photocopies of copyrighted material are not allowed. Notes in ink or highlighting are allowed in code sections only, and tabs must be permanently attached.
  • You may not write or mark in your references during the exam. PSI gives you a whiteboard, markers and scratch paper. Bring a battery-operated, non-programmable calculator without a printer.
  • Your name on the reservation must match your ID or you cannot test and forfeit the fee. Restroom breaks are limited to 5 minutes and the clock keeps running.
  • You see your result right after the exam. Passing candidates are told PASS with no numeric score; candidates who fail get diagnostic feedback by content area.
  • To retest you must reapply with the District before each attempt. The bulletin recommends allowing time to study before registering again.

Note: The PSI bulletin (updated 8/25/2022) lists the 2011 NEC and the 2012 IPC, IFGC and IMC, while the District's adopted construction codes are the 2017 DC Construction Codes (2014 NEC and 2015 ICC codes with D.C. amendments, effective May 29, 2020). We follow the editions on the bulletin. Confirm the current reference list with PSI (855-557-0616) or the DLCP before you buy books. No pass score is published.

Frequently asked questions

How many questions are on the D.C. journeyman plumber exam?

PSI lists 70 multiple-choice questions in 3 hours (exam ID 302), open book. The biggest areas are Plan Reading (27%), Drainage Requirements (16%), Vent Requirements (16%).

What is the passing score?

Neither PSI nor the Board of Industrial Trades publishes a passing score. PSI shows PASS or FAIL right after the exam, with no numeric score for passing candidates and diagnostic feedback for those who fail.

Which code edition does the exam use?

PSI's bulletin lists the 2012 International Plumbing Code (and the 2012 IFGC for gas). The District has since adopted the 2015 ICC codes in the 2017 DC Construction Codes, so confirm the current reference list with PSI or the DLCP before you buy books.

Free questions with answers

Show all 10 free questions and answers
  1. Which group of fixtures meets the 2012 IPC definition of a bathroom group when all are located together on the same floor level?

    Answer: A water closet, a lavatory, and a bathtub or shower

    Chapter 2 defines a bathroom group as a water closet, lavatory, and bathtub or shower, with or without a bidet, an emergency floor drain, or both, on the same floor level. Table 709.1 then gives the group a single drainage fixture unit value (5 dfu with a 1.6 gpf closet). A clothes washer or kitchen sink is not part of the group.

    Reference: 2012 International Plumbing Code, Chapter 2, Definitions: Bathroom group

  2. A floor drain in a rarely used mechanical room keeps losing its trap seal to evaporation. Where must a trap seal primer valve connect to the trap, and to which standard must the valve conform?

    Answer: At a point above the level of the trap seal; ASSE 1018 or ASSE 1044

    Section 1002.4 requires a trap seal primer valve where the seal is subject to evaporation loss. The valve connects to the trap above the level of the trap seal and must conform to ASSE 1018 or ASSE 1044. ASSE 1010 is for water hammer arresters, and ASSE 1016 and 1070 apply to shower and temperature-limiting valves.

    Reference: 2012 International Plumbing Code, 1002.4

  3. Which statement about a floor drain inside a walk-in freezer in a food service establishment is correct under Section 802.1.2?

    Answer: It must be indirectly connected by an air gap, and if the area is subject to freezing the waste line must not be trapped

    Section 802.1.2 requires floor drains in walk-in refrigerators and freezers of food establishments to be indirectly connected by an air gap. Where the drain is in an area subject to freezing, the waste line is not trapped and discharges to a waste receptor outside the freezing area. A backwater valve allows an air break or an air gap.

    Reference: 2012 International Plumbing Code, 802.1.2

  4. Soft, poor load-bearing soil is found at the bottom of a trench for a 4-inch drain. How deep must the trench be overexcavated before it is stabilized under Section 306.2.3?

    Answer: Not less than two pipe diameters, then backfilled with fine gravel, crushed stone, or a concrete foundation

    Section 306.2.3 says stabilization is achieved by overexcavating not less than two pipe diameters and backfilling to the pipe bottom with fine gravel, crushed stone, or a concrete foundation (which is bedded in tamped sand). For a 4-inch pipe that is 8 inches. The 3-inch depth in Section 306.2.2 applies to rock, not soft soil.

    Reference: 2012 International Plumbing Code, 306.2.3

  5. What is the minimum size of a cleanout serving a 6-inch building drain, according to Section 708.7?

    Answer: 4 inches

    Section 708.7 says cleanouts are the same nominal size as the pipe up to 4 inches, and for pipes larger than 4 inches the cleanout must be not less than 4 inches. For a 6-inch drain the cleanout need not be 6 inches.

    Reference: 2012 International Plumbing Code, 708.7

  6. How much clearance must be provided in front of a cleanout on an 8-inch drain for rodding?

    Answer: 36 inches

    Section 708.8 requires at least 18 inches of clearance for cleanouts on pipes 6 inches and smaller, and at least 36 inches for cleanouts on 8-inch and larger pipes.

    Reference: 2012 International Plumbing Code, 708.8

  7. A fixture drain is 2-inch pipe. Under Section 909.2, what is the greatest total fall permitted in that fixture drain because of its slope?

    Answer: 2 inches, equal to the drain diameter

    Section 909.2 says the total fall in a fixture drain due to pipe slope shall not exceed the diameter of the fixture drain. A 2-inch drain can therefore fall at most 2 inches between the trap weir and the vent connection, which also explains why the distances in Table 909.1 are limited.

    Reference: 2012 International Plumbing Code, 909.2

  8. A parallel-connected water distribution manifold is designed for a velocity of 4 feet per second and must supply a total demand of 8 gpm. Using Table 604.10.1, what is the smallest nominal manifold size?

    Answer: 1 inch

    At 4 feet per second, Table 604.10.1 allows 2 gpm for 1/2 inch, 6 gpm for 3/4 inch, 10 gpm for 1 inch, 15 gpm for 1-1/4 inch, and 22 gpm for 1-1/2 inch. 8 gpm exceeds 6 gpm and fits within 10 gpm, so a 1-inch manifold is the smallest. The total gpm is the demand of all the outlets supplied.

    Reference: 2012 International Plumbing Code, Table 604.10.1; 604.10.1

  9. A house has 16 dfu of fixtures, including water closets, all draining to a building drain laid at 1/4 inch per foot. Using Table 710.1(1) and its footnote, what is the smallest building drain size permitted?

    Answer: 3 inches

    At 1/4 inch per foot, Table 710.1(1) allows 21 dfu on a 2-inch drain and 24 dfu on a 2-1/2 inch drain, both above 16 dfu. But footnote a requires the minimum size of any building drain serving a water closet to be 3 inches, which controls here.

    Reference: 2012 International Plumbing Code, Table 710.1(1), footnote a

  10. A small bar plan shows two public water closets (1.6 gpf), one nonwater-supplied urinal, two lavatories, one service sink, and two floor drains. Using Table 709.1, what is the total drainage fixture unit load?

    Answer: 16.5 dfu

    Table 709.1 values: public 1.6 gpf water closet 4 dfu each (8), nonwater urinal 1/2 dfu, lavatory 1 dfu each (2), service sink 2 dfu, floor drain 2 dfu each (4). Total = 8 + 0.5 + 2 + 2 + 4 = 16.5 dfu. Treating the urinal as 1 dfu gives 17, and ignoring it gives 16.

    Reference: 2012 International Plumbing Code, Table 709.1

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.