Requirements at a glance
| Agency | Delaware Division of Professional Regulation, Board of Electrical Examiners; exams by Prov |
|---|---|
| Experience | Over 4,000 hours of full-time electrical work, or a Board-approved residential apprenticeship, under a master or limited electrician or while individually licensed (24 Del.C. 1408(a)(6)) |
| Exam | Residential electrician exam: 60 questions, 3 hours, 75% |
| Books allowed | NEC (edition per the Prov bulletin) and American Electrician's Handbook, 17th Edition |
| Fees | $100 to Prov per exam (2022 bulletin); DPR application and license fees are separate |
Electricians applying to the Delaware Board of Electrical Examiners for a residential electrician license, which covers one-, two- and multi-family dwellings.
Official links
How to get licensed, step by step
Apply to DPR
Create an account in the DELPROS portal and submit your application. The Board approves it before you can test.
Delaware DPR: Board of Electrical Examiners, exams (opens in a new tab)
Get your bulletin
Prov emails the candidate information bulletin, usually within 1 to 2 weeks. It lists the books and editions for your test date.
Pass the exam with Prov
Schedule at a Delaware test site or from home with remote proctoring. Results come the same day.
Get licensed
Send DPR your result and license fee, plus proof of general liability insurance as the Board requires (24 Del.C. 1411(a)). You can wait up to 12 months after passing to submit the fee and insurance proof; after that you retake the exam (1408(f)). Electrical licenses renew every 2 years.
Delaware DPR: Board of Electrical Examiners, exams (opens in a new tab)Delaware Code Title 24, Chapter 14 (Electricians) (opens in a new tab)
How to prepare
- Open book: bring the titles Prov lists (older or newer editions are allowed). Permanent tabs are fine; sticky notes and handwritten notes are not. Use a simple 4-function calculator.
- Delaware's State Fire Prevention Commission adopted the 2023 NEC effective January 1, 2026, and DPR says the exams follow the latest NEC adopted in Delaware. The 3/2022 Prov bulletin we could obtain lists 2020, so confirm the edition in the bulletin Prov sends you after DPR approves your application.
- General electrical knowledge and wiring and protection are 15 questions each; wiring methods and materials is 10.
- Focus on dwelling-unit rules: branch circuits, GFCI and AFCI, service and feeder calculations and grounding.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC and the American Electrician's Handbook. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 Edition (2020 edition listed in the 3/2022 bulletin)Essential
Allowed in the exam room. Delaware adopted the 2023 NEC effective January 1, 2026. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
American Electrician's Handbook, 17th Edition (McGraw Hill)Essential
Allowed in the exam room. Theory, calculations and general trade practice that the NEC does not cover.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), per the Prov bulletin (2020 edition listed in the 3/2022 bulletin; see the edition note)
- American Electrician's Handbook, 17th Edition (McGraw Hill)
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 15 | |
| Wiring & Protection | 15 | |
| Wiring Methods & Materials | 10 | |
| Equipment for General Use | 7 | |
| Special Equipment | 3 | |
| Special Conditions | 3 | |
| Communication Systems | 2 | |
| Plan Reading | 2 | |
| Motors & Controls | 3 |
Exam day details
- Administered by Prov, Inc. for the Delaware Division of Professional Regulation.
- Fee: $100 to Prov per exam (2022 bulletin). DPR application and license fees are separate.
- 60 questions in 3 hours; 75% to pass (per DPR).
- Open book: bring the exact titles Prov lists (older or newer editions are allowed). Permanent tabs are fine; repositionable tabs and sticky notes are not. Highlighting and underlining in pen are allowed, but handwritten notes, added formula sheets and stickers are not, and you may not mark your books during the test.
- Computer-based at Prov's Delaware test sites or at home with remote proctoring (Examroom). Use a simple 4-function calculator; no special calculators.
- Question counts and times are totals from the Prov bulletin (3/2022). The pass score comes from DPR's exam pages, not the bulletin. Prov emails the current bulletin after DPR approves your application, so use that copy for your test date.
- Change or cancel at least 3 business days before your test date to keep your fee. After a failure you can retest after 7 days.
Note: Delaware's State Fire Prevention Commission adopted the 2023 NEC effective January 1, 2026, and DPR says the electrical exams are based on the latest NEC adopted in Delaware. The Prov bulletin we could obtain (3/2022) still lists the 2020 NEC. Confirm the edition in the bulletin Prov sends you; our questions follow the 2023 NEC.
Frequently asked questions
What's on the Delaware residential electrician exam?
60 questions per the Prov bulletin: general electrical knowledge 15, wiring and protection 15, wiring methods and materials 10, equipment for general use 7, special equipment 3, special conditions 3, motors and controls 3, communication systems 2 and plan reading 2.
How long is the Delaware residential electrician exam?
3 hours for 60 questions. The pass score on DPR's page is 75%.
Free questions with answers
Show all 10 free questions and answers
A 120-volt branch circuit supplies a resistive heater that draws 12.5 amperes. What is the resistance of the heater?
Answer: 9.6 ohms
Ohm's law gives R = E / I = 120 / 12.5 = 9.6 ohms. Multiplying volts by amperes (1,500) gives watts, not ohms, and I / E inverts the formula.
Reference: NFPA 70, National Electrical Code, 2023, Ohm's law (E = I x R), general electrical theory
A 30-ohm resistor and a 60-ohm resistor are connected in parallel across a 120-volt source. What is the total current drawn from the source?
Answer: 6 amperes
The branch currents are 120 / 30 = 4 A and 120 / 60 = 2 A, so the total is 6 A. The equivalent resistance is (30 x 60) / (30 + 60) = 20 ohms, and 120 / 20 = 6 A. Adding the resistances (90 ohms) would give 1.3 A, which is the series result.
Reference: NFPA 70, National Electrical Code, 2023, Parallel circuit, Ohm's law
A receptacle in a dwelling unit utility room is installed 5 feet from the top inside edge of the bowl of a laundry sink. Does 210.8(A) require GFCI protection for it?
Answer: Yes, receptacles within 6 ft of the sink bowl need GFCI protection
210.8(A)(8) requires GFCI protection for 125- to 250-volt receptacles in dwelling units where installed within 1.8 m (6 ft) from the top inside edge of the bowl of a sink. The laundry area is also listed in 210.8(A)(11), so protection is required either way.
Reference: NFPA 70, National Electrical Code, 2023, 210.8(A)(8) and (A)(11)
What volume allowance does Table 314.16(B)(1) give for each 14 AWG conductor in a box?
Answer: 2.00 cubic inches
Table 314.16(B)(1) lists 2.00 cu in. for 14 AWG, 2.25 for 12 AWG and 2.50 for 10 AWG. Using the 12 AWG value for a 14 AWG conductor would oversize the calculation.
Reference: NFPA 70, National Electrical Code, 2023, Table 314.16(B)(1)
A 20-ampere, 125-volt receptacle is installed on a porch where it is exposed to rain. What does 406.9(B)(1) require for the cover?
Answer: A weatherproof enclosure whether or not a plug is inserted
406.9(B)(1) requires receptacles in wet locations to have an enclosure that is weatherproof with the attachment plug inserted or removed, typically a listed in-use (extra-duty) cover. A cover weatherproof only when closed is acceptable in damp locations only.
Reference: NFPA 70, National Electrical Code, 2023, 406.9(B)(1)
All receptacles installed for connecting an electric vehicle charger at a dwelling must have which protection under 625.54?
Answer: Ground-fault circuit-interrupter protection
625.54 requires GFCI protection for personnel on all receptacles installed for the connection of electric vehicle charging. AFCI protection is separate and is not the requirement of this section.
Reference: NFPA 70, National Electrical Code, 2023, 625.54
A homeowner wants a standby generator to power part of the house during outages. Which NEC article covers this optional standby system?
Answer: Article 702
Article 702 applies to optional standby systems, including permanently installed ones and those arranged for connection to premises wiring from a portable supply. Article 700 covers emergency systems and Article 701 legally required standby systems, which are not a home generator.
Reference: NFPA 70, National Electrical Code, 2023, 702.1
A communications primary protector at a dwelling is bonded with a copper bonding conductor. Under 800.100(A)(3), what is the largest size this conductor is ever required to be?
Answer: 6 AWG
800.100(A)(3) requires the bonding conductor or grounding electrode conductor to be not smaller than 14 AWG, with a current-carrying capacity not less than that of the cable's metallic sheath and protected conductors, but it is not required to exceed 6 AWG.
Reference: NFPA 70, National Electrical Code, 2023, 800.100(A)(3)
On a floor plan drawn at 1/4 in. = 1 ft, a living room wall with no doors or windows measures 7 inches. What is the minimum number of receptacles required on that wall under 210.52(A)(1)?
Answer: 3
Scale: 7 in. / (1/4 in. per ft) = 28 ft. Each receptacle serves up to 12 ft of wall (no point more than 6 ft from an outlet), so 28 / 12 = 2.33, which requires 3 receptacles. Two outlets cover only 24 ft.
Reference: NFPA 70, National Electrical Code, 2023, 210.52(A)(1)
What is the minimum branch-circuit conductor ampacity for a 1-hp, 230-volt single-phase motor, using Table 430.248 and 430.22?
Answer: 10 amperes
Table 430.248 gives 8 A full-load current for a 1-hp, 230-volt single-phase motor. 430.22 requires conductors of at least 125 percent: 8 x 1.25 = 10 A. The 16 A figure is the 115-volt value and 20 A is 250 percent.
Reference: NFPA 70, National Electrical Code, 2023, 430.22, Table 430.248
Sources
- Delaware DPR: Board of Electrical Examiners, exams (opens in a new tab)
- Prov, Inc.: Delaware licensing exams (opens in a new tab)
- Delaware Code Title 24, Chapter 14 (Electricians) (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.