Delaware licensing exam

Delaware Limited Electrician Exam: Practice Test & Licensing Guide

The Prov exam for Delaware's limited electrician license: 70 questions on the NEC for one-, two- and three-family dwellings. Open book.

Questions
70
Time limit
3 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Wiring & Protection

In the living room of a one-family dwelling, receptacles must be spaced so that no point along the floor line of a wall space is farther than what distance from a receptacle outlet?

Requirements at a glance

AgencyDelaware Division of Professional Regulation, Board of Electrical Examiners; exams by Prov
Experience3 years of full-time experience under a licensed master or limited electrician, or 4,000 hours plus 288 hours of related instruction or a registered apprenticeship certificate (24 Del.C. 1408(a)(2))
ExamLimited electrician exam: 70 questions, 3 hours, 75%
Books allowedNEC (edition per the Prov bulletin) and American Electrician's Handbook, 17th Edition
Fees$100 to Prov per exam (2022 bulletin); DPR application and license fees are separate

Electricians applying to the Delaware Board of Electrical Examiners for a limited electrician license covering one-, two- and three-family dwellings.

How to get licensed, step by step

  1. Apply to DPR

    Create an account in the DELPROS portal and submit your application. The Board approves it before you can test.

    Delaware DPR: Board of Electrical Examiners, exams (opens in a new tab)

  2. Get your bulletin

    Prov emails the candidate information bulletin, usually within 1 to 2 weeks. It lists the books and editions for your test date.

    Prov, Inc. (Delaware exams) (opens in a new tab)

  3. Pass the exam with Prov

    Schedule at a Delaware test site or from home with remote proctoring. Results come the same day.

    Prov, Inc. (Delaware exams) (opens in a new tab)

  4. Get licensed

    Send DPR your result and license fee, plus proof of general liability insurance as the Board requires (24 Del.C. 1411(a)). You can wait up to 12 months after passing to submit the fee and insurance proof; after that you retake the exam (1408(f)). Electrical licenses renew every 2 years.

    Delaware DPR: Board of Electrical Examiners, exams (opens in a new tab)Delaware Code Title 24, Chapter 14 (Electricians) (opens in a new tab)

How to prepare

  • Open book: bring the titles Prov lists (older or newer editions are allowed). Permanent tabs are fine; sticky notes and handwritten notes are not. Use a simple 4-function calculator.
  • Delaware's State Fire Prevention Commission adopted the 2023 NEC effective January 1, 2026, and DPR says the exams follow the latest NEC adopted in Delaware. The 3/2022 Prov bulletin we could obtain lists 2020, so confirm the edition in the bulletin Prov sends you after DPR approves your application.
  • General electrical knowledge (19), wiring and protection (16) and wiring methods and materials (16) are most of the exam.
  • The license covers one-, two- and three-family dwellings, so study Chapter 2 and Article 210 and 220 dwelling calculations closely.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC and the American Electrician's Handbook. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2023 Edition (2020 edition listed in the 3/2022 bulletin)Essential

    Allowed in the exam room. Delaware adopted the 2023 NEC effective January 1, 2026. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.

    NFPA store (opens in a new tab)Free online access (opens in a new tab)

  • American Electrician's Handbook, 17th Edition (McGraw Hill)Essential

    Allowed in the exam room. Theory, calculations and general trade practice that the NEC does not cover.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC), per the Prov bulletin (2020 edition listed in the 3/2022 bulletin; see the edition note)
  • American Electrician's Handbook, 17th Edition (McGraw Hill)

What's on the exam

Official content outline from Prov, Inc. (number of questions per topic):

TopicQuestions
General Electrical Knowledge19
Equipment for General Use5
Wiring & Protection16
Wiring Methods & Materials16
Special Occupancies2
Special Equipment3
Special Conditions3
Motors & Controls3
Communication Systems3

Exam day details

  • Administered by Prov, Inc. for the Delaware Division of Professional Regulation.
  • Fee: $100 to Prov per exam (2022 bulletin). DPR application and license fees are separate.
  • 70 questions in 3 hours; 75% to pass (per DPR).
  • Limited electrician applicants must show proof of general liability insurance to activate the license (24 Del.C. 1408 and 1410). The statute leaves the amount to the Board; 24 DE Admin Code 1400-6.1 sets $300,000 (confirm with DPR).
  • Open book: bring the exact titles Prov lists (older or newer editions are allowed). Permanent tabs are fine; repositionable tabs and sticky notes are not. Highlighting and underlining in pen are allowed, but handwritten notes, added formula sheets and stickers are not, and you may not mark your books during the test.
  • Computer-based at Prov's Delaware test sites or at home with remote proctoring (Examroom). Use a simple 4-function calculator; no special calculators.
  • Question counts and times are totals from the Prov bulletin (3/2022). The pass score comes from DPR's exam pages, not the bulletin. Prov emails the current bulletin after DPR approves your application, so use that copy for your test date.
  • Change or cancel at least 3 business days before your test date to keep your fee. After a failure you can retest after 7 days.

Note: Delaware's State Fire Prevention Commission adopted the 2023 NEC effective January 1, 2026, and DPR says the electrical exams are based on the latest NEC adopted in Delaware. The Prov bulletin we could obtain (3/2022) still lists the 2020 NEC. Confirm the edition in the bulletin Prov sends you; our questions follow the 2023 NEC.

Frequently asked questions

What's on the Delaware limited electrician exam?

70 questions per the Prov bulletin: general electrical knowledge 19, wiring and protection 16, wiring methods and materials 16, equipment for general use 5, special equipment 3, special conditions 3, motors and controls 3, communication systems 3 and special occupancies 2.

What work does a limited electrician license cover?

The bulletin describes it as design, installation, repair, alteration and maintenance in one-, two- and three-family dwellings.

Free questions with answers

Show all 10 free questions and answers
  1. In the living room of a one-family dwelling, receptacles must be spaced so that no point along the floor line of a wall space is farther than what distance from a receptacle outlet?

    Answer: 6 feet

    Section 210.52(A)(1) says no point measured horizontally along the floor line of any wall space may be more than 6 ft from a receptacle. The 12-ft figure is the old 'one receptacle every 12 feet' rule of thumb that results from this spacing (6 ft each way), not the measurement limit itself.

    Reference: NFPA 70, National Electrical Code, 2023, 210.52(A)(1)

  2. A homeowner wants a 120-volt, 20-ampere GFCI-protected circuit to a landscape receptacle, run in direct-buried Type UF cable. This is a residential branch circuit. What minimum burial depth does Table 300.5(A) require?

    Answer: 12 in.

    Table 300.5(A), Column 4 (residential branch circuits of 120 volts or less, GFCI-protected, 20 A maximum overcurrent protection) allows 12 in. of cover. Direct-buried cable in other locations (Column 1) needs 24 in., and 18 in. is the figure for nonmetallic raceways in Column 3.

    Reference: NFPA 70, National Electrical Code, 2023, Table 300.5(A)

  3. A 240-volt electric baseboard heater circuit has a total resistance of 12 ohms. How much current does the circuit carry?

    Answer: 20 A

    Ohm's law gives I = E / R = 240 / 12 = 20 A. 24 A comes from dividing by 10 instead of 12, 2,880 A multiplies voltage and resistance, and 0.05 A inverts the formula (R / E).

    Reference: Ohm's law and power formulas (basic electrical theory), I = E / R

  4. Three heating elements of 6, 10 and 14 ohms are connected in series across a 120-volt supply. What is the circuit current?

    Answer: 4.0 A

    In series the resistances add: 6 + 10 + 14 = 30 ohms. I = E / R = 120 / 30 = 4.0 A. 40.6 A results from treating them as parallel (equivalent about 2.96 ohms), and 0.25 A inverts the formula.

    Reference: Ohm's law and power formulas (basic electrical theory), Series circuit, R total = R1 + R2 + R3

  5. An electrician rewires a hallway lighting circuit in a new house using a switch loop that brings only a hot and a switched conductor to the switch box. Under the 2023 NEC, what does 404.2(C) require at that switch location?

    Answer: A grounded (neutral) conductor must be at the switch unless an exception applies, such as a raceway or automatic control

    Section 404.2(C) requires the grounded circuit conductor at switch locations where switches control lighting loads supplied by a grounded general-purpose branch circuit serving bathrooms, hallways, stairways and habitable rooms or occupiable spaces, so electronic lighting controls can operate. Exceptions include conductors entering through a raceway with enough area to add a grounded conductor later, automatic lighting control, and switches controlling receptacle loads. Travelers and extra grounding conductors do not satisfy the rule.

    Reference: NFPA 70, National Electrical Code, 2023, 404.2(C)

  6. A Class I, Division 1 location is one where ignitible concentrations of flammable gases or vapors exist under which condition (among others)?

    Answer: Under normal operating conditions

    Section 500.5(B)(1) defines a Class I, Division 1 location as one in which ignitible concentrations of flammable gases or vapors can exist under normal operating conditions (or frequently because of repair, maintenance or leakage, or where equipment failure may release them). Division 2 covers abnormal conditions such as accidental container rupture.

    Reference: NFPA 70, National Electrical Code, 2023, 500.5(B)(1)

  7. A permanently installed swimming pool at a dwelling needs its required general-purpose receptacle. Where must it be located relative to the inside wall of the pool?

    Answer: At least 6 ft and not more than 20 ft from the inside wall of the pool

    Section 680.22(A)(1) requires at least one 125-volt, 15- or 20-ampere general-purpose receptacle located not less than 6 ft and not more than 20 ft from the inside wall of the pool, not more than 6 ft 6 in. above the floor, platform or grade serving the pool.

    Reference: NFPA 70, National Electrical Code, 2023, 680.22(A)(1)

  8. Under the 2023 NEC, which statement about transfer switches used with an optional standby system is correct?

    Answer: Reconditioned transfer switches are not permitted

    New in 2023, Section 702.2 states that reconditioned transfer switches are not permitted in optional standby systems. Section 702.5(A) requires transfer equipment designed to prevent the inadvertent interconnection of all sources of supply.

    Reference: NFPA 70, National Electrical Code, 2023, 702.2

  9. A 2-hp, 230-volt, single-phase motor in a workshop at a house draws a nameplate current of 11 A. Using Table 430.248 and 430.22, what minimum ampacity do the branch-circuit conductors need for continuous duty?

    Answer: 15.0 A

    Conductor sizing under 430.6(A)(1) uses the Table 430.248 value, not the nameplate: a 2-hp, 230-V single-phase motor is 12 A. Section 430.22 requires 125 percent of that: 12 x 1.25 = 15 A. 13.8 A is the 200-volt-column value for the same motor, and 11 A ignores both the table and the 125 percent.

    Reference: NFPA 70, National Electrical Code, 2023, 430.22; Table 430.248

  10. A Class 2 low-voltage thermostat cable and 120-volt power conductors need to share the same device box. Under 725.136, what is generally required?

    Answer: A barrier separating them, or another arrangement permitted by 725.136(B) through (I)

    Section 725.136(A) prohibits Class 2 and Class 3 conductors from sharing a cable, enclosure, outlet box or raceway with light and power conductors unless permitted by 725.136(B) through (I). Barriers (B), raceways within enclosures (C) and associated-equipment arrangements (D) are among the exceptions.

    Reference: NFPA 70, National Electrical Code, 2023, 725.136(A), 725.136(B)

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.