Requirements at a glance
| Agency | Delaware Division of Professional Regulation, Board of Electrical Examiners; exams by Prov |
|---|---|
| Experience | Age 20 or older, plus either a Board-approved apprenticeship that ends in a final exam, or over 8,000 hours of full-time electrical work under a licensed master, master special, limited or limited special electrician (24 Del.C. 1408(a)(5)) |
| Exam | Journeyperson electrician exam: 70 questions, 3 hours, 75% |
| Books allowed | NEC (edition per the Prov bulletin) and American Electrician's Handbook, 17th Edition |
| Fees | $100 to Prov per exam (2022 bulletin); DPR application and license fees are separate |
Electricians applying to the Delaware Board of Electrical Examiners for a journeyperson license, which lets you work under the supervision of a master electrician.
Official links
How to get licensed, step by step
Apply to DPR
Create an account in the DELPROS portal and submit your application. The Board approves it before you can test.
Delaware DPR: Board of Electrical Examiners, exams (opens in a new tab)
Get your bulletin
Prov emails the candidate information bulletin, usually within 1 to 2 weeks. It lists the books and editions for your test date.
Pass the exam with Prov
Schedule at a Delaware test site or from home with remote proctoring. Results come the same day.
Get licensed
Send DPR your result and license fee, plus proof of general liability insurance as the Board requires (24 Del.C. 1411(a)). You can wait up to 12 months after passing to submit the fee and insurance proof; after that you retake the exam (1408(f)). Electrical licenses renew every 2 years.
Delaware DPR: Board of Electrical Examiners, exams (opens in a new tab)Delaware Code Title 24, Chapter 14 (Electricians) (opens in a new tab)
How to prepare
- Open book: bring the titles Prov lists (older or newer editions are allowed). Permanent tabs are fine; sticky notes and handwritten notes are not. Use a simple 4-function calculator.
- Delaware's State Fire Prevention Commission adopted the 2023 NEC effective January 1, 2026, and DPR says the exams follow the latest NEC adopted in Delaware. The 3/2022 Prov bulletin we could obtain lists 2020, so confirm the edition in the bulletin Prov sends you after DPR approves your application.
- Wiring methods and materials (22 of 70) and wiring and protection (14) make up half the exam. Tab Chapters 3 and 2 of the NEC and Chapter 9 tables.
- General electrical theory (9) covers Ohm's law, power and circuit calculations; the Handbook helps here.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC and the American Electrician's Handbook. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 Edition (2020 edition listed in the 3/2022 bulletin)Essential
Allowed in the exam room. Delaware adopted the 2023 NEC effective January 1, 2026. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
American Electrician's Handbook, 17th Edition (McGraw Hill)Essential
Allowed in the exam room. Theory, calculations and general trade practice that the NEC does not cover.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), per the Prov bulletin (2020 edition listed in the 3/2022 bulletin; see the edition note)
- American Electrician's Handbook, 17th Edition (McGraw Hill)
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Theory & Principles | 9 | |
| Plan Reading | 4 | |
| Equipment for General Use | 6 | |
| Motors & Controls | 3 | |
| Wiring & Protection | 14 | |
| Wiring Methods & Materials | 22 | |
| Communication Systems | 4 | |
| Special Conditions | 3 | |
| Special Equipment | 3 | |
| Special Occupancies | 2 |
Exam day details
- Administered by Prov, Inc. for the Delaware Division of Professional Regulation.
- Fee: $100 to Prov per exam (2022 bulletin). DPR application and license fees are separate.
- 70 questions in 3 hours; 75% to pass (per DPR).
- Journeyperson applicants need 8,000 hours of experience (4,000 under a master electrician) and must be 20 (24 Del.C. ch. 14).
- Open book: bring the exact titles Prov lists (older or newer editions are allowed). Permanent tabs are fine; repositionable tabs and sticky notes are not. Highlighting and underlining in pen are allowed, but handwritten notes, added formula sheets and stickers are not, and you may not mark your books during the test.
- Computer-based at Prov's Delaware test sites or at home with remote proctoring (Examroom). Use a simple 4-function calculator; no special calculators.
- Question counts and times are totals from the Prov bulletin (3/2022). The pass score comes from DPR's exam pages, not the bulletin. Prov emails the current bulletin after DPR approves your application, so use that copy for your test date.
- Change or cancel at least 3 business days before your test date to keep your fee. After a failure you can retest after 7 days.
Note: Delaware's State Fire Prevention Commission adopted the 2023 NEC effective January 1, 2026, and DPR says the electrical exams are based on the latest NEC adopted in Delaware. The Prov bulletin we could obtain (3/2022) still lists the 2020 NEC. Confirm the edition in the bulletin Prov sends you; our questions follow the 2023 NEC.
Frequently asked questions
What's on the Delaware journeyperson electrician exam?
70 questions per the Prov bulletin: wiring methods and materials 22, wiring and protection 14, general electrical theory and principles 9, equipment for general use 6, plan reading 4, communication systems 4, motors and controls 3, special conditions 3, special equipment 3 and special occupancies 2.
Is the Delaware electrician exam open book?
Yes. You may bring the NEC and the American Electrician's Handbook with permanent tabs, highlighting and underlining. Handwritten notes and sticky notes are not allowed.
Which NEC edition does Delaware use?
Delaware adopted the 2023 NEC effective January 1, 2026. The 3/2022 Prov bulletin lists 2020, so confirm the edition in the bulletin Prov sends you.
Free questions with answers
Show all 10 free questions and answers
A 480Y/277-volt panelboard is installed on one wall of an electrical room. A grounded concrete wall is directly opposite, with no live parts on that side. What is the minimum depth of working space in front of the panelboard?
Answer: 3 ft 6 in.
For 151 to 600 volts to ground, Table 110.26(A)(1) gives 3 ft for Condition 1, 3 ft 6 in. for Condition 2 and 4 ft for Condition 3. Live parts on one side and grounded parts (concrete counts as grounded) on the other is Condition 2, so 3 ft 6 in. 3 ft is Condition 1 and 4 ft is Condition 3.
Reference: NFPA 70, National Electrical Code, 2023, Table 110.26(A)(1)
In a dwelling-unit living room, receptacle outlets must be placed so that no point measured horizontally along the floor line of a wall space is more than what distance from a receptacle outlet?
Answer: 6 ft
Section 210.52(A)(1) sets the general spacing so that no point along the floor line of any wall space is more than 6 ft from an outlet, which in practice means outlets no more than 12 ft apart. Wall space includes any unbroken stretch 2 ft or wider. The 12 ft figure is the spacing between outlets, not the distance to the nearest outlet.
Reference: NFPA 70, National Electrical Code, 2023, 210.52(A)(1)
Using Table 300.5(A), what is the minimum cover for Type UF cable direct buried under a one-family dwelling's lawn, where the circuit is a 120-volt, 20-ampere branch circuit with GFCI protection?
Answer: 12 in.
Table 300.5(A), Column 4 covers residential branch circuits rated 120 volts or less with GFCI protection and a maximum 20 A overcurrent device, requiring 12 in. of cover in the general (all other locations) row. Column 1 would require 24 in. for direct-burial cable without that GFCI protection, and 6 in. applies to rigid metal conduit.
Reference: NFPA 70, National Electrical Code, 2023, Table 300.5(A)
A cord-and-plug-connected in-sink waste disposer is installed under a kitchen sink. Within what range must the length of the flexible cord fall under 422.16(B)(1)?
Answer: 18 in. to 36 in.
Section 422.16(B)(1) permits an in-sink waste disposer to be cord-and-plug connected when the cord is identified as suitable by the installation instructions, is at least 18 in. and not more than 36 in. long, the receptacle is located to protect the cord from damage, and the receptacle is accessible. Dishwashers and trash compactors use a different length, 3 ft to 4 ft.
Reference: NFPA 70, National Electrical Code, 2023, 422.16(B)(1)
A 3-phase, 230-volt, 10 hp motor has a nameplate full-load current of 26 A. What is the minimum ampacity of the branch-circuit conductors supplying this single continuous-duty motor?
Answer: 35 A
Section 430.22 requires ampacity of at least 125 percent of the motor full-load current as determined by 430.6(A)(1), which means the Table 430.250 value, not the nameplate. A 10 hp, 230 V three-phase motor is listed at 28 A, so 28 x 1.25 = 35 A. 28 A omits the 125 percent, and 32.5 A wrongly uses the nameplate (26 x 1.25).
Reference: NFPA 70, National Electrical Code, 2023, 430.22 and Table 430.250
In the event of failure of the normal supply, an emergency system must make power available within what maximum time?
Answer: 10 seconds
Section 700.12 requires emergency lighting or power to be available within the time required for the application but not to exceed 10 seconds. The 60 second figure is the limit for legally required standby systems in 701.12.
Reference: NFPA 70, National Electrical Code, 2023, 700.12
A plan is drawn at 1/4 in. = 1 ft. A 208Y/120-volt panelboard has exposed live parts on one side of its working space and no live or grounded parts opposite. How deep in inches must the required working space be drawn on the plan?
Answer: 3/4 in.
For 0 to 150 volts to ground, Table 110.26(A)(1) requires 3 ft of depth for every condition. At 1/4 in. per foot, 3 ft x 1/4 = 3/4 in. on the drawing. 1 in. corresponds to 4 ft, which is the 151-600 volt Condition 3 depth, and 1 1/4 in. would be 5 ft.
Reference: NFPA 70, National Electrical Code, 2023, Table 110.26(A)(1)
What is the minimum size of a communications bonding conductor or grounding electrode conductor under 800.100(A)(3)?
Answer: 14 AWG
Section 800.100(A)(3) says the bonding conductor or grounding electrode conductor shall not be smaller than 14 AWG, and it is not required to exceed 6 AWG. It must also have current-carrying capacity not less than the aggregate of the cable's metallic sheath and protected conductors.
Reference: NFPA 70, National Electrical Code, 2023, 800.100(A)(3)
An EVSE draws a maximum continuous load of 48 amperes. Under 625.41, what is the minimum rating of the overcurrent protective device for its branch circuit?
Answer: 60 A
Section 625.41 requires overcurrent protection for EVSE circuits to be sized for continuous duty at not less than 125 percent of the maximum load of the equipment. 48 x 1.25 = 60 A, which is a standard rating in 240.6(A). 48 A is 100 percent of the load and 56 A is not a standard rating.
Reference: NFPA 70, National Electrical Code, 2023, 625.41
In a Class I, Division 1 location, a conduit runs into an enclosure that contains arcing or sparking devices. Within what distance of the enclosure must the conduit seal be installed?
Answer: 18 in.
Section 501.15(A)(1) requires conduit seals to be installed within 450 mm (18 in.) of an enclosure that contains arcing or sparking devices. The seal prevents flames and gases moving through the conduit into the rest of the system. The 12, 24 and 36 in. distances are not the rule.
Reference: NFPA 70, National Electrical Code, 2023, 501.15(A)(1)
Sources
- Delaware DPR: Board of Electrical Examiners, exams (opens in a new tab)
- Prov, Inc.: Delaware licensing exams (opens in a new tab)
- Delaware Code Title 24, Chapter 14 (Electricians) (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.