Connecticut licensing exam

Connecticut P-2 Unlimited Journeyperson Plumber Exam: Practice Test & Licensing Guide

The PSI trade exam for Connecticut's P-2 unlimited journeyperson plumber license: 70 questions on the IPC, gas systems, drain, waste and vent, isometrics and water treatment. Open book.

Questions
70
Time limit
2.5 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Plumbing Regulations

A plumber is laying out a new water service line in Connecticut. Under the Connecticut-amended IPC, what is the minimum depth at which the water service pipe must be installed?

Requirements at a glance

AgencyConnecticut Department of Consumer Protection (DCP); exams by PSI
ExperienceA completed registered apprenticeship with at least 4 years of experience in the trade, or equivalent experience and training DCP accepts (CGS 20-334a; RCSA 20-332); age 18
ExamsP-2 plumbing exam: 70 questions, 2.5 hours, 70%
Books allowedIPC (2015, 2018 or 2021), NFPA 54 (2012), NFPA 58 (2014), NFPA 56, 29 CFR 1926 and Water Processing 3rd edition
Fees$59 at PSI; DCP $90 application fee (CGS 20-333) and $120 initial license fee (CGS 20-335); renews yearly for $120

Plumbers with a registered apprenticeship and at least 4 years of experience applying for a Connecticut P-2 unlimited journeyperson plumber license.

How to get licensed, step by step

  1. Confirm you qualify

    Journeyperson licenses need a completed registered apprenticeship with at least 4 years of experience (or equivalent experience and training DCP accepts), then the trade exam only.

    Connecticut DCP: trade license examinations (opens in a new tab)Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)

  2. Apply to DCP

    DCP decides whether you are eligible to test. Once approved, you contact PSI to pay and schedule.

    Connecticut DCP: trade license examinations (opens in a new tab)

  3. Pass the trade exam with PSI

    Both are open book at $59 each. You can test as often as needed for up to one year from your eligibility date. A passing Business and Law score counts for 2 years toward another contractor license.

    Schedule with PSI (Connecticut occupational licenses) (opens in a new tab)

  4. Get licensed

    Send DCP your passing score report or reports with the license fee shown on it.

    Connecticut DCP: trade license examinations (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's list. You can highlight, underline, annotate and index them with permanent tabs, but you can't write in them during the exam and Post-It notes are not allowed.
  • Connecticut's 2022 State Building Code uses the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments, and points to NFPA 54 and NFPA 58 for fuel gas (the IFGC is not adopted). The bulletin allows several editions, so check it for your test date.
  • Drain, waste and vent is 11 of 70 questions. Tab the DWV sizing tables and the venting chapter.
  • Fixtures and equipment (6) and isometric analysis (6) are the next largest sections.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the IPC and NFPA 54. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Plumbing Code, 2015, 2018 or 2021 edition (allowed in the exam room)
  • NFPA 54: National Fuel Gas Code or Handbook, 2012 (allowed in the exam room)
  • NFPA 58: Liquefied Petroleum Gas Code, 2014 (allowed in the exam room)
  • NFPA 56: Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems (allowed in the exam room)
  • 29 CFR Part 1926 (OSHA), or the PSI selections (allowed in the exam room)
  • Water Processing: Residential, Commercial, Light Industrial, 3rd Edition, Water Quality Association (allowed in the exam room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Plumbing Regulations4
Gas Systems5
Cleanouts4
Fixtures and Equipment6
Water Heaters2
Piping, Valves, Controls3
Water Supply5
Hangers and Supports4
Drain, Waste, and Vent11
Backflow3
Traps and Interceptors4
Developed length3
Isometric Analysis6
Joints and Connections4
Safety and Excavation3
Water Treatment3

Exam day details

  • Administered by PSI Services for the Connecticut Department of Consumer Protection.
  • Fee: $59 to PSI per exam portion. DCP license fees are separate.
  • 70 questions in 2.5 hours; 70% to pass.
  • Connecticut's 2022 State Building Code (effective 10/1/2022) is based on the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments. The PSI bulletin (updated 2/4/2026) still lists the 2020 or 2023 NEC and the 2015, 2018 or 2021 IPC or IMC; check the current bulletin for your test date.
  • Journeyperson applicants take only the trade exam; there is no Business and Law portion.
  • Open book: bring your own copies of the allowed references. You may highlight, underline, annotate and index them beforehand, but not write in them during the exam. Permanent tabs only; Post-It notes are not allowed.
  • Use a silent, nonprinting, non-programmable calculator. For code questions the exam is based only on the edition of the code book listed in the bulletin.
  • Candidates may test as often as needed for up to one year from the date of eligibility. Contractor exam portions (business and trade) are each valid for 2 years from the date passed.
  • Contractor and dealer licenses need two portions: the Business and Law exam and the trade exam. Journeyperson licenses need only the trade exam.

Frequently asked questions

What's on the Connecticut P-2 exam?

70 questions: drain, waste and vent 11, isometric analysis 6, fixtures and equipment 6, gas systems 5, water supply 5, then smaller sections including general regulations, cleanouts, hangers, traps and interceptors and joints.

Does the P-2 journeyperson exam include Business and Law?

No. Journeyperson applicants take only the trade exam.

What experience do I need for the P-2?

A registered Connecticut Department of Labor apprenticeship and at least 4 years of experience, as set out in CGS 20-334a. Confirm current requirements with DCP.

Free questions with answers

Show all 10 free questions and answers
  1. A plumber is laying out a new water service line in Connecticut. Under the Connecticut-amended IPC, what is the minimum depth at which the water service pipe must be installed?

    Answer: 48 inches

    Connecticut amends Section 305.4 to state that water service pipe shall be installed not less than 48 inches deep, and it deletes the model-code Section 305.4.1 on sewer depth. The shallower values are common frost-depth guesses from other jurisdictions, but the Connecticut text fixes the service depth at 48 inches.

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), 305.4

  2. A 6-inch building sewer runs 260 feet from the building to the public sewer connection. What does Section 708.1.2 require for cleaning access along this sewer?

    Answer: Cleanouts at intervals of not more than 100 feet

    Section 708.1.2 says building sewers smaller than 8 inches need cleanouts at intervals of not more than 100 feet. The manhole rule (first manhole within 200 feet of the building drain and sewer junction, then every 400 feet) applies only to building sewers 8 inches and larger.

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), 708.1.2

  3. Under footnote b of Table 308.5, what is required for 2-inch PVC pipe installed vertically with supports at the maximum vertical spacing?

    Answer: A guide midway between the required vertical supports

    Footnote b to Table 308.5 requires that for sizes 2 inches and smaller, a guide be installed midway between required vertical supports. The guide prevents movement perpendicular to the axis of the pipe. It does not replace the supports.

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), Table 308.5, footnote b

  4. A water closet is being set next to a side wall. What is the minimum distance from the center of the water closet to the wall under Section 405.3.1?

    Answer: 15 inches

    Section 405.3.1 says a water closet, urinal, lavatory or bidet cannot be set closer than 15 inches from its center to any side wall, partition, vanity or other obstruction. Adjacent fixtures not separated by a partition must be at least 30 inches center to center.

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), 405.3.1

  5. Which fitting arrangement is NOT considered a reduction in pipe size in the direction of flow under Section 704.2?

    Answer: A 4-inch by 3-inch water closet flange

    Section 704.2 forbids reducing drainage pipe size in the direction of flow, but lists exceptions: a 4-inch by 3-inch water closet flange, a closet bend with a 4-inch inlet and 3-inch outlet whose 4-inch leg is upright and below the flange, and an offset closet flange.

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), 704.2

  6. Which type of trap is prohibited under Section 1002.3?

    Answer: An S trap

    Section 1002.3 prohibits traps that depend on moving parts, bell traps, crown-vented traps, traps depending on interior partitions (with limited exceptions), S traps and drum traps. Building (house) traps are separately prohibited by Section 1002.6.

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), 1002.3

  7. A public toilet room building drain, sloped 1/8 inch per foot, serves 6 public water closets (1.6 gpf), 6 lavatories, 2 urinals rated 1 gallon per flush or less, 1 service sink and 2 floor drains. Using Tables 709.1 and 710.1(1), what is the minimum building drain size?

    Answer: 4 inches

    Table 709.1: 6 public water closets at 4 = 24; 6 lavatories at 1 = 6; 2 urinals at 2 = 4; 1 service sink at 2 = 2; 2 floor drains at 2 = 4. Total = 24 + 6 + 4 + 2 + 4 = 40 dfu. Table 710.1(1) at 1/8 inch per foot allows 36 dfu on 3 inches and 180 on 4 inches, so 4 inches is required. A building drain serving a water closet is never smaller than 3 inches.

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), Tables 709.1 and 710.1(1)

  8. Using Table 604.3, what minimum flow pressure must be available at the supply outlet of a siphonic water closet with a flushometer valve?

    Answer: 35 psi

    Table 604.3 lists siphonic flushometer-valve water closets at 25 gpm and 35 psi, blow-out flushometer-valve water closets at 25 gpm and 45 psi, and tank-type water closets at 20 psi. Mixing up the siphonic and blow-out types is the usual error.

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), Table 604.3

  9. A new low-pressure (7 inches water column) fuel gas piping system is to be pressure tested under NFPA 54 (2012). The test pressure must be at least 1.5 times the maximum working pressure, but not less than what value?

    Answer: 3 psig

    NFPA 54 (2012) Section 8.1.4 (Test Pressure) requires the test pressure to be not less than 1 1/2 times the proposed maximum working pressure, but not less than 3 psig, irrespective of design pressure. A 7 inches water column system works at about 0.25 psi, and 1.5 x 0.25 = 0.375 psi, well under 3 psi, so the 3 psig minimum controls. (Section 8.1.3 covers test preparation, not test pressure.)

    Reference: NFPA 54, National Fuel Gas Code (2012), 8.1.4 (Test Pressure)

  10. What must be used for soldered joints in potable water supply piping under Section 605.12.3?

    Answer: Lead-free solder and flux

    Section 605.12.3 requires copper pipe solder joints to be made per ASTM B828 with tube ends reamed, flux conforming to ASTM B813 and solder conforming to ASTM B32, and says the joining of water supply piping shall be made with lead-free solder and flux. Section 605.2 caps the lead content of water supply pipe and fittings at 8 percent, and 0.25 percent for drinking water (Section 605.2.1).

    Reference: 2021 International Plumbing Code with Connecticut amendments (2022 CT State Building Code), 605.12.3

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.