Connecticut licensing exam

Connecticut F-2 Unlimited Fire Sprinkler Journeyperson Exam: Practice Test & Licensing Guide

The PSI trade exam for Connecticut's F-2 unlimited fire sprinkler journeyperson license: 80 questions covering NFPA fire sprinkler, standpipe, pump and inspection standards. Open book.

Questions
80
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Fire Sprinkler Systems (13, 13R, 13D)

An extra hazard area is hydraulically calculated to a design density greater than 0.25 gpm/ft2. What is the maximum protection area per standard spray sprinkler?

Requirements at a glance

AgencyConnecticut Department of Consumer Protection (DCP); exams by PSI
ExperienceA completed bona fide apprenticeship and at least 4 years of experience in fire protection sprinkler systems work, or a prior sprinkler license (CGS 20-334a(c)(2)); age 18
ExamsF-2 fire sprinkler exam: 80 questions, 3 hours, 70%
Books allowedNFPA 11, 11A, 12, 13, 13D, 13R, 14, 15, 16, 17, 17A, 20, 22, 24, 25, 45, 96, 101, 170, 230 and 2001, in the editions on the PSI bulletin
Fees$59 at PSI; DCP application and license fees are set in CGS 20-333 and 20-335 (the license fee for non-contractor licenses is $120)

Fire sprinkler fitters with a completed apprenticeship and at least 4 years of experience (or a prior F-2 license) applying for a Connecticut F-2 license from DCP.

How to get licensed, step by step

  1. Confirm you qualify

    Journeyperson licenses need a completed registered apprenticeship with at least 4 years of experience (or equivalent experience and training DCP accepts), then the trade exam only.

    Connecticut DCP: trade license examinations (opens in a new tab)Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)

  2. Apply to DCP

    DCP decides whether you are eligible to test. Once approved, you contact PSI to pay and schedule.

    Connecticut DCP: trade license examinations (opens in a new tab)

  3. Pass the trade exam with PSI

    Both are open book at $59 each. You can test as often as needed for up to one year from your eligibility date. A passing Business and Law score counts for 2 years toward another contractor license.

    Schedule with PSI (Connecticut occupational licenses) (opens in a new tab)

  4. Get licensed

    Send DCP your passing score report or reports with the license fee shown on it.

    Connecticut DCP: trade license examinations (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's list. You can highlight, underline, annotate and index them with permanent tabs, but you can't write in them during the exam and Post-It notes are not allowed.
  • The PSI fire sprinkler exams are based on the NFPA editions on the bulletin (usually two editions of each standard, such as NFPA 13 2002 or 2013). Study from the edition you will bring, and check the bulletin for your test date.
  • Sprinkler system design and installation (NFPA 13, 13R and 13D) is 35 of 80 questions.
  • Wet and dry chemical systems (12) and inspection, testing and maintenance (NFPA 25) (7) come next.
  • Fire pumps (NFPA 20) 5 and private service mains (NFPA 24) 4.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from NFPA 13. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 13, 13D and 13R: Installation of Sprinkler Systems, 2002 or 2013Essential

    Allowed in the exam room. Over a third of the F-1 and F-2 exams (35 questions).

    NFPA store (opens in a new tab)NFPA free online access (opens in a new tab)

  • NFPA 25: Inspection, Testing and Maintenance of Water-Based Fire Protection Systems, 2002 or 2014

    Allowed in the exam room. Source for the inspection, testing and maintenance questions.

    NFPA store (opens in a new tab)

  • NFPA 14, 20, 22, 24, 96, 101, 170 and 230 and the chemical and foam standards (11, 12, 15, 16, 17, 17A, 45, 2001)

    Allowed in the exam room, in the editions on the PSI bulletin. Standpipes, pumps, tanks, private mains, kitchens, life safety, symbols, storage and special-hazard systems.

    NFPA store (opens in a new tab)

Official reference list (as published by the testing agency)
  • NFPA 13: Installation of Sprinkler Systems, 2002 or 2013 (allowed in the exam room)
  • NFPA 13D (one- and two-family dwellings and manufactured homes) and NFPA 13R (residential occupancies up to four stories), each 2002 or 2013 (allowed in the exam room)
  • NFPA 14: Standpipe, Private Hydrant and Hose Systems, 2003 or 2013 (allowed in the exam room)
  • NFPA 20: Stationary Pumps for Fire Protection, 2002 or 2013; NFPA 22: Water Tanks for Private Fire Protection, 2003 or 2013; NFPA 24: Private Fire Service Mains, 2002 or 2013 (allowed in the exam room)
  • NFPA 25: Inspection, Testing and Maintenance of Water-Based Fire Protection Systems, 2002 or 2014 (allowed in the exam room)
  • NFPA 96: Ventilation Control and Fire Protection of Commercial Cooking Operations, 2001 or 2014 (allowed in the exam room)
  • NFPA 101: Life Safety Code, 2003 or 2012; NFPA 170: Fire Safety Symbols, 2002 or 2012; NFPA 230: Fire Protection of Storage, 1999 or 2003 (allowed in the exam room)
  • NFPA 11 (2002 or 2010), 11A (1999), 12 (2000 or 2011), 15 (2001 or 2012), 16 (2003 or 2011), 17 (2002 or 2013), 17A (2002 or 2013), 45 (2003 or 2011) and 2001 (2004 or 2012) (allowed in the exam room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Fire Sprinkler Systems (13, 13R, 13D)35
Fire Sprinkler Wet and Dry Chemical Systems (17, 17a, 11, 11a, 12, 15, 16, 2001)12
Fire Sprinkler Standpipe (14)6
Fire Protection Storage (230)2
Commercial Kitchen Equipment (96)2
Inspection, testing and maintenance (25)7
General Knowledge and Regulations (170, 101)5
Fire Pumps (20)5
Tanks (22)2
Private Service Mains (24)4

Exam day details

  • Administered by PSI Services for the Connecticut Department of Consumer Protection.
  • Fee: $59 to PSI per exam portion. DCP license fees are separate.
  • 80 questions in 3 hours; 70% to pass. Open book.
  • The license covers fire protection sprinkler systems work (CGS 20-330 and 20-334a).
  • Connecticut's PSI fire sprinkler exams are based on the NFPA editions listed in the bulletin (updated 2/4/2026), usually a pair of editions per standard. Check the bulletin for your test date.
  • This exam uses the NFPA editions the bulletin lists, which are older than the editions adopted in the current State Fire Code; study the edition on your bulletin.
  • Open book: bring your own copies of the allowed references. You may highlight, underline, annotate and index them beforehand, but not write in them during the exam. Permanent tabs only; Post-It notes are not allowed.
  • Use a silent, nonprinting, non-programmable calculator. For code questions the exam is based only on the edition of the code book listed in the bulletin.
  • Candidates may test as often as needed for up to one year from the date of eligibility. Contractor exam portions (business and trade) are each valid for 2 years from the date passed.
  • Contractor and dealer licenses need two portions: the Business and Law exam and the trade exam. Journeyperson licenses need only the trade exam.

Frequently asked questions

What's on the Connecticut F-2 exam?

80 questions: sprinkler systems (NFPA 13, 13R, 13D) 35, wet and dry chemical systems 12, inspection, testing and maintenance 7, standpipes 6, then general knowledge, pumps, private service mains, storage, kitchen equipment and tanks.

Is the F-2 open book?

Yes. You may bring the allowed references listed on the PSI bulletin, tabbed with permanent tabs, and use a silent, non-programmable calculator.

Do I need the Business and Law exam for the F-2?

No. Journeyperson applicants take only the trade exam.

Free questions with answers

Show all 10 free questions and answers
  1. An extra hazard area is hydraulically calculated to a design density greater than 0.25 gpm/ft2. What is the maximum protection area per standard spray sprinkler?

    Answer: 100 square feet, with 12 ft maximum spacing

    Table 8.6.2.2.1(c) lists 100 ft2 and 12 ft for hydraulically calculated extra hazard systems with density over 0.25 gpm/ft2; at densities under 0.25 the table allows 130 ft2 and 15 ft. The 90 ft2 and 12 ft value is the extra hazard pipe-schedule entry.

    Reference: NFPA 13 (2002), Table 8.6.2.2.1(c)

  2. The allowable distance between sprinklers on a branch line of an ordinary hazard system is 15 ft. What is the maximum distance from the last sprinkler to the end wall, measured perpendicular to the wall?

    Answer: 7 ft 6 in.

    Section 8.6.3.2.1 limits the distance from a sprinkler to a wall to one-half of the allowable distance between sprinklers, so 15 ft / 2 = 7.5 ft (7 ft 6 in.), measured perpendicular to the wall per 8.6.3.2.2. The 4 in. figure is the minimum distance from a wall (8.6.3.3), a different limit.

    Reference: NFPA 13 (2002), 8.6.3.2.1 and 8.6.3.2.2

  3. A hand hose line is part of a dry chemical system. What is the minimum duration of effective use the quantity of dry chemical must support?

    Answer: 30 seconds

    Section 8.3.1 requires a hand hose line to have enough dry chemical for effective use for a minimum of 30 seconds, with sufficient flow rate to prevent surging or interrupted discharge (8.3.1.1). Where several hose lines can be used at once, the supply must cover the maximum number likely to operate for 30 seconds (8.3.2).

    Reference: NFPA 17 (2002), 8.3.1 and 8.3.2

  4. How often must maintenance be performed on a dry chemical extinguishing system under NFPA 17 (2002), in accordance with the manufacturer's manual?

    Answer: At least semiannually

    Section 11.3.1 requires maintenance at least semiannually according to the manufacturer's listed installation and maintenance manual. The owner's quick check inspection is the monthly task in 11.2.1, and annual replacement applies only to fusible-link elements (11.3.2).

    Reference: NFPA 17 (2002), 11.3.1

  5. A non-sprinklered building has six Class I standpipes. What total flow must the system demand include under NFPA 14 (2003)?

    Answer: 1,250 gpm

    The first standpipe needs 500 gpm and each additional standpipe 250 gpm: 500 + 5 x 250 = 1,750 gpm. Section 7.10.1.1.3 caps the total at 1,250 gpm, or 1,000 gpm for buildings sprinklered throughout, so 1,250 gpm governs here.

    Reference: NFPA 14 (2003), 7.10.1.1.3

  6. What is the minimum headroom required in a means of egress in new construction under NFPA 101 (2003), excluding the stated exceptions?

    Answer: 90 in., with ceiling projections not less than 80 in. above the floor

    Section 7.1.5.1 requires headroom not less than 90 in. with ceiling projections not less than 80 in. nominal above the finished floor. The 84 in. ceiling height applies to existing buildings under 7.1.5.1.1.

    Reference: NFPA 101 (2003), 7.1.5.1 and 7.1.5.1.1

  7. At what interval must dry sprinklers that have been in service for 10 years be tested or replaced under NFPA 25 (2002), and how often are they retested after that?

    Answer: Tested or replaced at 10 years, then retested at 10-year intervals

    Section 5.3.1.1.1.5 requires dry sprinklers in service for 10 years to be tested or replaced, and if maintained and serviced they are retested at 10-year intervals. The 50-year rule is for standard sprinklers.

    Reference: NFPA 25 (2002), 5.3.1.1.1.5

  8. Under NFPA 20, at what minimum head must a centrifugal fire pump deliver 150 percent of its rated capacity?

    Answer: Not less than 65 percent of total rated head

    Section 6.2.1 requires pumps to furnish not less than 150 percent of rated capacity at not less than 65 percent of total rated head. Together with the shutoff limit in 6.2.2, it defines the allowable curve.

    Reference: NFPA 20 (2016 text; 2013 edition allowed), 6.2.1

  9. What is the minimum water temperature that must be maintained in a fire protection water tank under NFPA 25 (2002)?

    Answer: 40 degrees F

    Section 9.2.4.1 requires tank water temperature not less than 40 deg F (4 deg C). Temperatures are inspected and recorded weekly in the heating season where low temperature alarms report to an attended location, otherwise daily (9.2.4.2 and 9.2.4.3).

    Reference: NFPA 25 (2002), 9.2.4.1 through 9.2.4.3

  10. How often must hydrants on a private fire service main be flow tested under NFPA 25 (2002), and for how long must each be flowed?

    Answer: Annually; each hydrant flowed fully for not less than 1 minute

    Section 7.3.2 requires annual hydrant testing, with the hydrant opened fully and flowed until foreign material clears (7.3.2.1) for not less than 1 minute (7.3.2.2). Dry barrel hydrants must then drain fully within 60 minutes (7.3.2.4).

    Reference: NFPA 25 (2002), 7.3.2.1, 7.3.2.2 and 7.3.2.4

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.