Requirements at a glance
| Agency | Connecticut Department of Consumer Protection (DCP); exams by PSI |
|---|---|
| Experience | At least 2 years as a licensed unlimited journeyperson in the trade, or equivalent experience and training DCP accepts (CGS 20-334a; RCSA 20-332); age 18 |
| Exams | P-1 plumbing exam: 80 questions, 3 hours, 70%, plus the Business and Law exam |
| Books allowed | IPC (2015, 2018 or 2021), NFPA 54 (2012), NFPA 58 (2014), NFPA 56, 29 CFR 1926 and Water Processing 3rd edition |
| Fees | $59 per PSI exam portion; DCP $150 application fee (CGS 20-333) and $150 initial license fee (CGS 20-335); renews yearly for $150 |
Plumbers with at least 2 years as a journeyperson applying for a Connecticut P-1 unlimited plumbing contractor license from the Department of Consumer Protection.
Official links
How to get licensed, step by step
Confirm you qualify
Contractor licenses need at least 2 years as a licensed journeyperson (or equivalent experience and training DCP accepts), plus both the Business and Law exam and the trade exam.
Connecticut DCP: trade license examinations (opens in a new tab)Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)
Apply to DCP
DCP decides whether you are eligible to test. Once approved, you contact PSI to pay and schedule.
Connecticut DCP: trade license examinations (opens in a new tab)
Pass both exam portions with PSI
Both are open book at $59 each. You can test as often as needed for up to one year from your eligibility date. A passing Business and Law score counts for 2 years toward another contractor license.
Schedule with PSI (Connecticut occupational licenses) (opens in a new tab)
Get licensed
Send DCP your passing score report or reports with the license fee shown on it.
Connecticut DCP: trade license examinations (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's list. You can highlight, underline, annotate and index them with permanent tabs, but you can't write in them during the exam and Post-It notes are not allowed.
- Connecticut's 2022 State Building Code uses the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments, and points to NFPA 54 and NFPA 58 for fuel gas (the IFGC is not adopted). The bulletin allows several editions, so check it for your test date.
- Drain, waste and vent is 14 of 80 questions. Tab the DWV sizing tables and the venting chapter.
- Isometric analysis is 9 questions. Practice adding fixture units from a riser diagram and sizing drains and vents.
- Gas systems (9) come from NFPA 54, not the IFGC.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the IPC and NFPA 54. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Plumbing Code (IPC), 2015, 2018 or 2021 (Connecticut adopts 2021 with amendments)Essential
Allowed in the exam room. The core of the plumbing exams.
NFPA 54: National Fuel Gas Code (or Handbook), 2012Essential
Allowed in the exam room. Connecticut uses NFPA 54 rather than the IFGC. Use the longest length method for pipe sizing.
NFPA 58: Liquefied Petroleum Gas Code, 2014
Allowed in the exam room. LP-gas storage, piping and appliances.
Water Processing: Residential, Commercial, Light Industrial, 3rd Edition (WQA)
Allowed in the plumbing exam room. Source for the water treatment questions.
29 CFR 1926 (OSHA Construction Standards), sections on your reference list
Trenching, scaffolds, fall protection and ladders. Print just the listed sections.
Official reference list (as published by the testing agency)
- International Plumbing Code, 2015, 2018 or 2021 edition (allowed in the exam room)
- NFPA 54: National Fuel Gas Code or Handbook, 2012 (allowed in the exam room)
- NFPA 58: Liquefied Petroleum Gas Code, 2014 (allowed in the exam room)
- NFPA 56: Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems (allowed in the exam room)
- 29 CFR Part 1926 (OSHA), or the PSI selections (allowed in the exam room)
- Water Processing: Residential, Commercial, Light Industrial, 3rd Edition, Water Quality Association (allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Plumbing Regulations | 4 | |
| Gas Systems | 9 | |
| Cleanouts | 4 | |
| Fixtures and Equipment | 5 | |
| Water Heaters | 2 | |
| Piping, Valves, Controls | 3 | |
| Water Supply | 6 | |
| Hangers and Supports | 3 | |
| Drain, Waste, and Vent | 14 | |
| Backflow | 3 | |
| Traps and Interceptors | 4 | |
| Developed length | 2 | |
| Isometric Analysis | 9 | |
| Joints and Connections | 3 | |
| Safety and Excavation | 6 | |
| Water Treatment | 3 |
Exam day details
- Administered by PSI Services for the Connecticut Department of Consumer Protection.
- Fee: $59 to PSI per exam portion. DCP license fees are separate.
- 80 questions in 3 hours; 70% to pass.
- Connecticut's 2022 State Building Code (effective 10/1/2022) is based on the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments. The PSI bulletin (updated 2/4/2026) still lists the 2020 or 2023 NEC and the 2015, 2018 or 2021 IPC or IMC; check the current bulletin for your test date.
- Connecticut has not adopted the International Fuel Gas Code. Gas questions are based on NFPA 54 (2012 on the bulletin), NFPA 58 and NFPA 56.
- Open book: bring your own copies of the allowed references. You may highlight, underline, annotate and index them beforehand, but not write in them during the exam. Permanent tabs only; Post-It notes are not allowed.
- Use a silent, nonprinting, non-programmable calculator. For code questions the exam is based only on the edition of the code book listed in the bulletin.
- Candidates may test as often as needed for up to one year from the date of eligibility. Contractor exam portions (business and trade) are each valid for 2 years from the date passed.
- Contractor and dealer licenses need two portions: the Business and Law exam and the trade exam. Journeyperson licenses need only the trade exam.
Frequently asked questions
What's on the Connecticut P-1 exam?
80 questions: drain, waste and vent 14, gas systems 9, isometric analysis 9, water supply 6, safety and excavation 6, fixtures and equipment 5, then smaller sections including cleanouts, traps and interceptors, general regulations, hangers, backflow, joints and water treatment.
Which gas code applies to Connecticut plumbers?
NFPA 54, not the IFGC. The bulletin lists NFPA 54 (2012), NFPA 58 (2014) and NFPA 56.
Do I also need the Business and Law exam?
Yes. Contractor licenses need both the Business and Law exam and the P-1 trade exam.
Free questions with answers
Show all 10 free questions and answers
A reduced pressure principle backflow assembly has just been installed on a commercial building's water service in Connecticut. Who is responsible for having the required test performed, and who receives copies of the report?
Answer: The owner arranges the test by a qualified tester, and copies of the report go to the local building official
IPC 312.10.2 as amended in Connecticut requires reduced pressure, double check, pressure vacuum breaker, spill-proof vacuum breaker and detector assemblies and hose connection backflow preventers to be tested at installation by individuals or agencies qualified to do so. The owner is responsible for having the tests performed and copies of the reports go to the local building official. Testing follows the listed ASSE or CSA B64.10 standards, and 312.10.2.1 points to Regulations of Connecticut State Agencies 19-13-B38a.
Reference: 2021 International Plumbing Code (Connecticut amendments, 2022 CSBC), 312.10.2
A horizontal 4-inch building drain makes a 90-degree change of horizontal direction, and 25 feet of developed length downstream it makes a second 90-degree change of horizontal direction. No other changes of direction occur nearby. How many cleanouts does Section 708.1.4 require for these two changes?
Answer: One, installed at the first change, which serves both
Section 708.1.4 requires a cleanout at a horizontal change of direction greater than 45 degrees. When more than one such change occurs within 40 feet of developed length, the cleanout for the first change serves all changes within that 40 feet. Here the second bend is only 25 feet downstream, so one cleanout is enough.
Reference: 2021 International Plumbing Code (Connecticut amendments, 2022 CSBC), 708.1.4
Under the simplest sloping option of 29 CFR 1926.652(b)(1), with no soil classification done, what is the steepest allowed slope for an excavation?
Answer: 1 1/2 horizontal to 1 vertical
Option (1) in 1926.652(b)(1) allows excavations sloped at an angle not steeper than 1 1/2 horizontal to 1 vertical (34 degrees from horizontal), which matches the Type C soil slope in Appendix B. Steeper slopes such as 1:1 or 3/4:1 are only allowed for Type B and Type A soils classified under the other options.
Reference: 29 CFR Part 1926, Subpart P (OSHA excavations), 29 CFR 1926.652(b)(1)
A 4-inch drainage stack ends at a horizontal building drain. How far downstream of the stack base must a horizontal branch be connected, at minimum, under Section 704.3?
Answer: 40 inches
Section 704.3 requires horizontal branches to connect to the base of a stack at a point not less than 10 times the stack diameter downstream. For a 4-inch stack that is 10 x 4 = 40 inches. The same 10-diameter rule applies to horizontal stack offsets.
Reference: 2021 International Plumbing Code (Connecticut amendments, 2022 CSBC), 704.3
Which of the following must never be used as the test medium when pressure testing gas piping?
Answer: Oxygen
Gas piping may be tested with air, nitrogen, carbon dioxide or another inert gas. Oxygen shall never be used because it can react violently with oil and grease in the pipe and fittings.
Reference: NFPA 54 National Fuel Gas Code (2012), 8.1.2
Using Table 604.3, what flow pressure must the water distribution system provide at the supply outlet of a blow-out type flushometer-valve water closet?
Answer: 45 psi at 25 gpm
Table 604.3 requires 25 gpm at 45 psi for a blow-out flushometer-valve water closet. A siphonic flushometer-valve water closet needs 25 gpm at 35 psi, a valve-type urinal needs 12 gpm at 25 psi, and a tank-type close-coupled water closet needs 3 gpm at 20 psi.
Reference: 2021 International Plumbing Code (Connecticut amendments, 2022 CSBC), Table 604.3
According to Section 606.2, on which of the following must a shutoff valve be installed?
Answer: The water supply pipe to each sillcock
Section 606.2 requires shutoff valves on the fixture supply to each plumbing fixture (with exceptions for bathtubs and showers in one- and two-family dwellings and for unit shutoffs in hotel sleeping units), on the water supply pipe to each sillcock, and on the supply to each appliance or mechanical equipment.
Reference: 2021 International Plumbing Code (Connecticut amendments, 2022 CSBC), 606.2
A lavatory in a remodel has its trap weir located 28 inches below the fixture outlet, with the trap inlet centered 20 inches horizontally from the fixture outlet. Which limit in Section 1002.1 does the installation violate?
Answer: The vertical distance from the fixture outlet to the trap weir may not exceed 24 inches
Section 1002.1 requires the vertical distance from the fixture outlet to the trap weir to be not more than 24 inches and the horizontal distance, centerline of the fixture outlet to centerline of the trap inlet, not more than 30 inches. The horizontal 20 inches is acceptable, but the 28-inch vertical drop exceeds 24 inches.
Reference: 2021 International Plumbing Code (Connecticut amendments, 2022 CSBC), 1002.1
A water closet is being roughed in beside a wall. What is the minimum distance from the center of the water closet to the nearest side wall, under Section 405.3.1?
Answer: 15 inches
Section 405.3.1 requires water closets, urinals, lavatories and bidets to be at least 15 inches from center to any side wall, partition, vanity or obstruction, at least 30 inches center to center between adjacent fixtures, and to have at least 21 inches clearance in front. The 21 inches is the front clearance, not the side distance.
Reference: 2021 International Plumbing Code (Connecticut amendments, 2022 CSBC), 405.3.1
A horizontal fixture branch serves a kitchen sink with a food waste disposer and a dishwasher (both connected), a residential automatic clothes washer and a laundry tray. Using Table 709.1, what is the total drainage fixture unit load on the branch?
Answer: 6 dfu
Table 709.1 lists a domestic kitchen sink with a food waste disposer, dishwasher or both as one entry of 2 dfu, a residential automatic clothes washer at 2 dfu and a laundry tray at 2 dfu. Load = 2 + 2 + 2 = 6 dfu. Adding the dishwasher separately gives the common wrong answer of 8.
Reference: 2021 International Plumbing Code (Connecticut amendments, 2022 CSBC), Table 709.1
Sources
- PSI: Connecticut Plumbing Examinations Candidate Information Bulletin (updated 2/4/2026) (opens in a new tab)
- Connecticut Department of Consumer Protection: trade license examinations (opens in a new tab)
- Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)
- Connecticut DAS: State Building Code regulations (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.