Requirements at a glance
| Agency | Arkansas HVACR Licensing Board (Department of Labor and Licensing); exams by Prov |
|---|---|
| Experience | Applicants with no license history need 2 years of experience as an HVACR contractor or employee of one, or Board-approved training (17 CAR 261; our copy is an August 2025 draft) |
| Exam | Class E HVACR, refrigeration (60 questions, 3 hours, 70% to pass, open book) |
| Books allowed | The Arkansas HVAC/R Law and Rules, the 2018 or 2021 IMC, Modern Refrigeration and Air Conditioning (21st Edition) and Refrigeration and Air Conditioning Technology (9th Edition) |
| Fees | $100 per computer-based exam ($55 paper/pencil), plus Board application and license fees |
Refrigeration contractors applying to the Arkansas HVACR Licensing Board for a Class E license, which covers refrigeration work as defined in Ark. Code 17-33-101 without a horsepower limit. A Class E licensee may not sell, install or service heating and air conditioning equipment used for human comfort. Applicants with no license history need 2 years of experience as an HVACR contractor or employee, or Board-approved training.
Official links
How to get licensed, step by step
Apply to the Board
Send the HVACR Licensing Board your Class E application. The Board must pre-approve you before you schedule. Questions: adll.hvac@arkansas.gov or 501-682-9201.
Arkansas Department of Labor and Licensing: HVACR licensing (opens in a new tab)
Schedule with Prov
After approval, schedule the computer-based exam with Prov and pay the $100 exam fee. Approval lasts one year.
Prov (schedule your exam) (opens in a new tab)Prov: Arkansas HVACR candidate bulletin (2025.07.03, archived copy) (opens in a new tab)
Pass the exam
The exam is open book and timed, with a 70% cut score. Permanent tabs are fine; photocopied books, sticky notes and test-prep guides are not allowed.
Prov: Arkansas HVACR candidate bulletin (2025.07.03, archived copy) (opens in a new tab)
Get licensed
Pay the license fee. A Class A, B, D or E licensee is the designated license holder for the company.
Arkansas Department of Labor and Licensing: HVACR licensing (opens in a new tab)
How to prepare
- Download the Arkansas HVAC/R Law and Rules (free PDFs from the Department of Labor and Licensing); every HVACR exam has a law and administration section and you may bring printed copies.
- The 2018 or 2021 IMC and IFGC (or the Arkansas Fuel Gas Code) are allowed. The Board adopted the 2021 International Mechanical Code effective July 1, 2022.
- Class E covers refrigeration of any horsepower: it does not allow selling, installing or servicing comfort heating and air conditioning. Systems and sizing and piping are the biggest areas.
- Review IMC Chapter 11 (refrigeration) and the refrigeration textbooks Prov lists.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 International Mechanical Code (IMC)Essential
Adopted for HVACR in 17 CAR 261-121, effective July 1, 2022. Prov allows the 2018 or 2021 edition.
Official reference list (as published by the testing agency)
- Arkansas HVAC/R Law (free PDF from the Department of Labor and Licensing; candidate-printed copies allowed)
- Arkansas HVAC/R Rules and Regulations (free PDF from the Department; candidate-printed copies allowed)
- International Mechanical Code (IMC), 2018 or 2021 edition
- Modern Refrigeration and Air Conditioning, 21st Edition (ISBN 978-1-63563-877-6)
- Refrigeration and Air Conditioning Technology, 9th Edition (Cengage, ISBN 978-0-3571-2227-3)
What's on the exam
Official content outline from Prov (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Plan Reading, Estimating & Math | 10 | |
| General Knowledge | 10 | |
| Systems & Sizing | 16 | |
| Piping | 12 | |
| Maintenance | 8 | |
| Law and Administration | 4 |
Exam day details
- Administered by Prov for the Arkansas HVACR Licensing Board (Department of Labor and Licensing).
- Fee: $100 for the computer-based exam ($55 paper/pencil) per Prov's bulletin; 17 CAR 261-106(g) also sets $100. Board application and license fees are separate.
- Prov's bulletin: 60 questions in 3 hours, open book, 70% cut score. Our practice exam uses the same counts and the same six subject areas.
- Computer-based exam from Prov (paper/pencil is cheaper). The HVACR Licensing Board must pre-approve you before you schedule; approval lasts one year.
- All Prov HVACR exams are open book and timed, with a 70% cut score. Books may carry permanent tabs; photocopied books, sticky notes and test-prep study guides are not allowed. The Arkansas HVAC/R Law and Rules may be printed.
- 17 CAR Part 261 was rewritten after Act 746 of 2025. The copy we studied is an August 2025 draft, so check the final rule.
Note: Format, subject areas and references come from Prov's HVACR bulletin dated July 3, 2025. 17 CAR Part 261 was rewritten after Act 746 of 2025 and our copy is an August 2025 draft, so confirm license limits and any exam changes with the Board and Prov.
Frequently asked questions
What's on the Arkansas HVACR Class E exam?
Six subject areas: systems and sizing (16 questions), piping (12), plan reading, estimating and math (10), general knowledge (10), maintenance (8) and law and administration (4).
What does a Class E license allow?
Refrigeration work without a horsepower limit. It does not allow selling, installing or servicing heating and air conditioning equipment used for human comfort.
Which books are allowed?
The Arkansas HVAC/R Law and Rules, the 2018 or 2021 IMC, Modern Refrigeration and Air Conditioning (21st Edition) and Refrigeration and Air Conditioning Technology (9th Edition).
Free questions with answers
Show all 10 free questions and answers
A commercial occupancy has one 8,000 cubic foot enclosed occupied space that does not communicate with any other space. A single refrigerant circuit holding 230 pounds of R-410A (Group A1) has refrigerant-containing parts in that space. Table 1103.1 lists R-410A at 26 pounds per 1,000 cubic feet. Under Section 1104.2, what is required?
Answer: The refrigerant-containing components must be outdoors or in a machinery room, because 230 lb exceeds the 208 lb limit
Per Section 1104.2, components must be outdoors or in a machinery room when the circuit quantity exceeds the Table 1103.1 amount for the occupied space. Section 1104.4.1 uses the volume of the smallest enclosed occupied space: 26 lb/1,000 ft3 x 8 = 208 lb. The circuit holds 230 lb, which is more than 208 lb. The 6.6 lb figure is the threshold for listed equipment exemptions and stop valves, not the machinery room test.
Reference: 2021 International Mechanical Code (Arkansas, 17 CAR 261-121), Sections 1104.2, 1104.4.1 and Table 1103.1
A refrigeration system using R-134a (13 pounds per 1,000 cubic feet in Table 1103.1) serves an enclosed commercial occupied space of 12,000 cubic feet. The independent circuit holds 140 pounds. Does Section 1104.2 require a machinery room?
Answer: No, because 13 lb/1,000 ft3 x 12 = 156 lb, and the 140 lb charge does not exceed it
The Table 1103.1 amount is per 1,000 cubic feet of occupied space. For 12,000 ft3, the limit is 13 x 12 = 156 lb. A 140 lb circuit does not exceed 156 lb, so Section 1104.2 does not force a machinery room (other code provisions still apply). Comparing 140 lb with the bare 13 lb figure forgets to scale by room volume.
Reference: 2021 International Mechanical Code (Arkansas, 17 CAR 261-121), Sections 1104.2, 1104.4.1 and Table 1103.1
A contractor plans to use soft annealed copper tubing with a 1-5/8 inch outside diameter for field-assembled refrigerant piping that will be exposed to mechanical damage. Under the notes to Table 1107.4, is this permitted?
Answer: No, soft annealed tubing larger than 1-3/8 inch OD must be protected from mechanical damage
A note to Table 1107.4 says soft annealed copper tubing larger than 1-3/8 inch OD shall not be used for field-assembled refrigerant piping unless it is protected from mechanical damage. Smaller soft tubing and hard-drawn tubing are allowed under the table's standards.
Reference: 2021 International Mechanical Code (Arkansas, 17 CAR 261-121), Table 1107.4, notes
How must the ends of refrigerant pipe be prepared before joining, according to IMC Section 1108.2?
Answer: Cut square, reamed and chamfered, free from burrs, with a full-bore opening
Section 1108.2 requires pipe to be cut square, reamed and chamfered, free of burrs and obstructions, with full-bore openings that are not undercut. Burrs restrict flow and can break off into the system.
Reference: 2021 International Mechanical Code (Arkansas, 17 CAR 261-121), Section 1108.2
What must be displayed on service and installation vehicles used in HVACR contracting, according to the Board's licensee responsibility rule?
Answer: The license number and company name in letters at least 2 inches high on both sides
17 CAR 261-116(b)(1) requires each licensed contractor to display, prominently and legibly, the license number and company name in letters not less than 2 inches high on both sides of all service and installation vehicles used for air conditioning and refrigeration contracting.
Reference: 17 CAR 261 (HVACR Licensing Board rule; August 2025 draft text), 17 CAR 261-116(b)(1)
A grocery store owner wants to convert a system that holds 250 pounds of R-404A (Group A1) to another A1 refrigerant. What does IMC Section 1101.7 require before the change?
Answer: Prior notification to the code official and compliance with the code provisions for the new refrigerant
Section 1101.7 applies to circuits holding more than 220 pounds of Group A1 refrigerant, or more than 30 pounds of any other group. This system holds 250 lb of A1, which exceeds 220 lb, so the code official must be notified in advance and the provisions for the new refrigerant must be met.
Reference: 2021 International Mechanical Code (Arkansas, 17 CAR 261-121), Section 1101.7
A technician pulls a vacuum of 20 inches of mercury (gauge, below atmospheric) on a system. Using 29.92 inches of mercury = 14.7 psia as atmospheric pressure, what is the absolute pressure in the system?
Answer: 4.87 psia
A vacuum reading is measured below atmospheric pressure. The absolute pressure equals atmospheric minus the vacuum: 29.92 - 20 = 9.92 inches of mercury absolute. Convert to psia: 14.7 x 9.92 / 29.92 = 4.87 psia. The 9.83 psia figure is the vacuum itself (14.7 x 20 / 29.92), not the pressure that remains.
Reference: Standard refrigeration principle (not a code section), Absolute pressure = atmospheric - vacuum (29.92 in. Hg = 14.7 psia)
A 1.5 hp motor has an efficiency of 80 percent. Using 1 hp = 746 W and efficiency = output / input, how many watts of electrical input does it draw at full load?
Answer: 1,399 W
Output = 1.5 x 746 = 1,119 W. Input = output / efficiency = 1,119 / 0.80 = 1,399 W. Multiplying by 0.80 instead of dividing gives 895 W, which is lower than the output, which is impossible.
Reference: Standard refrigeration principle (not a code section), Input watts = (hp x 746) / efficiency
In the basic vapor-compression refrigeration cycle, in which component does high-pressure refrigerant vapor give up heat and change into a liquid?
Answer: The condenser
The compressor raises the pressure and temperature of the vapor, and the condenser removes heat from it until it liquefies. The IMC defines a condenser as a heat exchanger designed to liquefy refrigerant vapor by removal of heat. The metering device then lowers the liquid pressure before it enters the evaporator.
Reference: 2021 International Mechanical Code (Arkansas, 17 CAR 261-121), Chapter 2, definition of Condenser
With the compressor idle, the design pressure of a refrigeration system will not be exceeded even after the whole refrigerant charge has evaporated. What does the IMC call such a system?
Answer: A limited charge system
The IMC defines a limited charge system as one in which, with the compressor idle, the design pressure will not be exceeded when the refrigerant charge has completely evaporated. A self-contained system is a factory-assembled and tested system with no field-joined refrigerant-containing parts other than companion or block valves.
Reference: 2021 International Mechanical Code (Arkansas, 17 CAR 261-121), Chapter 2, definition of Limited Charge System
Sources
- Arkansas Department of Labor and Licensing: HVACR licensing (opens in a new tab)
- Prov: Arkansas HVACR candidate information bulletin (2025.07.03, archived copy) (opens in a new tab)
Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.