Alaska Unlimited Commercial and Industrial Plumbing Mechanical Administrator Exam: Practice Test & Licensing Guide

The PSI exam for Alaska's unlimited commercial and industrial plumbing mechanical administrator license: 100 questions on the 2018 UPC, NFPA 54, drainage, venting, water piping and isometrics. Open book.

Questions
100
Time limit
4 hours
Passing score
70%
Books
Open book

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10AK Statutes and Regs

A plumbing administrator qualifies a registered contractor in a city where five mechanical administrators have their principal place of business. A second contractor asks him to qualify its business too. Under AS 08.40.280, what is the answer?

Requirements at a glance

AgencyAlaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI
ExperienceSet by 12 AAC 32 (electrical) and 12 AAC 39 (mechanical); for the unlimited categories, for example 4 of the last 6 years as a journeyman plus management experience, or an equivalent
Exam100 questions, 4 hours, 70%
Books allowedUPC 2018, NFPA 54 (2018), Uniform Solar Energy Code 2018, USPSHTC 2018 and the Alaska mechanical statutes and regulations
Fee$150 to PSI per registration, plus the CBPL application and license fees

Plumbers seeking a mechanical administrator license in the unlimited commercial and industrial plumbing category from the Alaska CBPL.

How to get licensed, step by step

  1. Apply to the CBPL

    Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.

    Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)

  2. Schedule the unlimited plumbing exam with PSI

    Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.

    Schedule with PSI (mechanical administrators) (opens in a new tab)

  3. Pass the exam

    You need 70%. Scores are valid for 12 months toward the license.

    Schedule with PSI (mechanical administrators) (opens in a new tab)

  4. Get licensed

    Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.

    Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
  • Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
  • Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
  • General knowledge (22) is the largest section; isometric analysis is 10 questions, so practice sizing a drain and vent from a diagram.
  • Alaska revises UPC 612.2 and 1210.2.3.1 (8 AAC 63.010): read those two sections as amended.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

    Official reference list (as published by the testing agency)
    • Uniform Plumbing Code (UPC), 2018 edition, with Alaska revisions (8 AAC 63.010)
    • NFPA 54 National Fuel Gas Code, 2018 edition
    • Uniform Solar Energy Code, 2018 edition
    • Uniform Swimming Pool, Spa and Hot Tub Code (USPSHTC), 2018 edition
    • Alaska Mechanical Administrator Statutes and Regulations (AS 08.40; 12 AAC 39)
    • Alaska Centralized Regulations and Statutes

    What's on the exam

    Official content outline from PSI Services (number of questions per topic):

    TopicQuestions
    General Knowledge22
    AK Statutes and Regs10
    Drainage, Waste, Sanitary incl. Vents14
    Fuel Gas and Oil10
    Water Piping Systems10
    Specialty Plumbing12
    Plumbing Fixtures6
    Roof and Storm Drain Piping6
    Isometric Analysis10

    Exam day details

    • Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
    • Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
    • 100 scored questions in 4 hours; 70 correct (70%) to pass. Plus up to 10 unscored experimental items.
    • Experience (12 AAC 39): for example 4 of the last 6 years as a journeyman plus management experience, or an equivalent. Check the Division's current rules.
    • Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
    • PSI may add 1 to 10 unscored experimental items, which count against your time.
    • The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
    • Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.

    Frequently asked questions

    What is on the Alaska unlimited plumbing administrator exam?

    100 questions: general knowledge 22, drainage, waste and vents 14, specialty plumbing 12, fuel gas and oil 10, water piping 10, Alaska statutes and regulations 10, isometric analysis 10, plumbing fixtures 6 and roof and storm drain piping 6.

    Which plumbing code is used?

    The 2018 UPC with Alaska's revisions to 612.2 and 1210.2.3.1 (8 AAC 63.010).

    Free questions with answers

    Show all 10 free questions and answers
    1. A plumbing administrator qualifies a registered contractor in a city where five mechanical administrators have their principal place of business. A second contractor asks him to qualify its business too. Under AS 08.40.280, what is the answer?

      Answer: Not allowed, because the city is the principal place of business of three or more mechanical administrators

      AS 08.40.280 bars a person from qualifying or operating as administrator for more than one registered contractor or other business entity, unless the community is the principal place of business of fewer than three mechanical administrators. Five administrators means the exception does not apply. Personal inspection (AS 08.40.400) or the business form does not change this.

      Reference: Alaska Statutes AS 08.40 (mechanical administrators), AS 08.40.280

    2. What is the minimum uniform slope for a 3-inch horizontal drainage pipe under the UPC?

      Answer: 1/4 inch per foot (2 percent)

      UPC 708.1 requires horizontal drainage piping to run at a uniform slope of not less than 1/4 inch per foot (2 percent) toward the point of disposal. The 1/8 inch per foot slope is allowed only for pipe 4 inches and larger, and only where the slope cannot practically be met and the Authority Having Jurisdiction approves it first.

      Reference: 2018 Uniform Plumbing Code (UPC) as adopted in Alaska, 8 AAC 63.010, Section 708.1

    3. Under UPC 1210.3.2, where may concealed gas piping in a building NOT be located?

      Answer: In solid partitions

      UPC 1210.3.2 [NFPA 54:7.3.3] says concealed gas piping shall not be located in solid partitions. Hollow-wall tubing is covered in 1210.3.3, chases in 1210.4 and industrial floor channels in 1210.3.4, so those are allowed with their conditions.

      Reference: 2018 Uniform Plumbing Code (UPC) as adopted in Alaska, 8 AAC 63.010, Sections 1210.3.2-1210.3.4

    4. What is the minimum residual pressure the UPC requires at the fixtures before a tank and pump or other pressure-boosting means is needed (for fixtures with no higher requirement)?

      Answer: 15 psi

      UPC 608.1: where the water pressure in the main or other source will not provide a residual pressure of at least 15 psi after allowing for friction and other pressure losses, a tank and pump or other means that provides 15 psi must be installed. Fixtures that need more residual pressure set a higher minimum.

      Reference: 2018 Uniform Plumbing Code (UPC) as adopted in Alaska, 8 AAC 63.010, Section 608.1

    5. A site-built shower receptor is being laid out. Under UPC 408.6, what must the finished interior of the shower compartment provide, regardless of shape?

      Answer: At least 1,024 square inches, and able to contain a 30-inch circle

      UPC 408.6 requires a minimum finished interior of 1,024 square inches that also encompasses a 30-inch circle, measured at the top of the threshold and maintained up to a point 70 inches above the drain. Smaller areas such as 900 square inches or a 24-inch circle do not satisfy the UPC.

      Reference: 2018 Uniform Plumbing Code (UPC) as adopted in Alaska, 8 AAC 63.010, Section 408.6

    6. Under UPC 1101.16.2, how are the sanitary and storm drainage systems of a building to be arranged where a separate storm sewer is available?

      Answer: Entirely separate, with no connection between them

      UPC 1101.16.2: the sanitary and storm drainage systems of a building shall be entirely separate, except where a combined sewer is used, in which case the building storm drain connects in the same horizontal plane through a single wye to the combined sewer at least 10 feet downstream from a soil stack.

      Reference: 2018 Uniform Plumbing Code (UPC) as adopted in Alaska, 8 AAC 63.010, Section 1101.16.2

    7. Which statement about a sand interceptor is correct under UPC 1016?

      Answer: It must have a water seal of at least 6 inches and be vented

      UPC 1016.4 requires sand and similar interceptors to be readily accessible for cleaning, to have a water seal of at least 6 inches, and to be vented. 1016.3 requires an interior baffle and an outlet pipe the same size as the inlet, minimum 3 inches.

      Reference: 2018 Uniform Plumbing Code (UPC) as adopted in Alaska, 8 AAC 63.010, Sections 1016.3, 1016.4

    8. A trench is excavated parallel to a footing and deeper than the footing. Under UPC 314.1, how must the trench be located?

      Answer: Not less than 45 degrees from the bottom exterior edge of the footing

      UPC 314.1: trenches deeper than the footing of a building and paralleling it must be located not less than 45 degrees from the bottom exterior edge of the footing, or as approved under Section 301.0. This keeps the excavation outside the footing's load-bearing zone.

      Reference: 2018 Uniform Plumbing Code (UPC) as adopted in Alaska, 8 AAC 63.010, Section 314.1

    9. A plumber needs a waste connection for a floor sink near a water closet. Under UPC 310.3, which connection is prohibited?

      Answer: A waste connection to the closet bend or stub of the water closet

      UPC 310.3 prohibits any waste connection to a closet bend or stub of a water closet or similar fixture. Other drainage connections follow Chapter 7, and 310.2 adds that drainage or vent piping may not be drilled and tapped and cast-iron soil pipe may not be threaded.

      Reference: 2018 Uniform Plumbing Code (UPC) as adopted in Alaska, 8 AAC 63.010, Sections 310.2, 310.3

    10. An isometric shows a vertical drain stack that must be offset sideways with two 45 degree fittings. The offset (set) is 9 inches. How long is the diagonal piece between the fittings (travel), using the 1.414 multiplier?

      Answer: 12.7 inches

      For a 45 degree offset, travel = set x 1.414. 9 in x 1.414 = 12.73 in, about 12.7 inches (before fitting makeup is deducted). 9.0 forgets the multiplier, 6.4 uses 0.707 (the inverse), and 18.0 doubles the set.

      Reference: General plumbing practice (right-triangle offset geometry), 45-degree offset: travel = set x 1.414

    Sources

    Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.