Alaska licensing exam

Alaska Residential Plumbing and Hydronic Heating Mechanical Administrator Exam: Practice Test & Licensing Guide

The PSI exam for Alaska's residential plumbing and hydronic heating mechanical administrator license: 100 questions on the 2018 UPC, NFPA 54 and 2012 IMC, plus hydronic heating and isometrics. Open book.

Questions
100
Time limit
4 hours
Passing score
70%
Books
Open book

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10AK Statutes

At renewal, a residential plumbing and hydronic heating administrator must complete one eight-hour continuing education workshop. Under 12 AAC 39.410(b)(3), which code coverage satisfies the requirement?

Requirements at a glance

AgencyAlaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI
ExperienceSet by 12 AAC 39.312; the license covers single-family and duplex dwellings up to three stories
Exam100 questions, 4 hours, 70%
Books allowedUPC 2018, NFPA 54 (2018), IMC 2012 and the Alaska mechanical statutes and regulations
Fee$150 to PSI per registration, plus the CBPL application and license fees

Plumbers and hydronic installers seeking a mechanical administrator license for single-family and duplex dwellings up to three stories.

How to get licensed, step by step

  1. Apply to the CBPL

    Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.

    Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)

  2. Schedule the residential plumbing and hydronic exam with PSI

    Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.

    Schedule with PSI (mechanical administrators) (opens in a new tab)

  3. Pass the exam

    You need 70%. Scores are valid for 12 months toward the license.

    Schedule with PSI (mechanical administrators) (opens in a new tab)

  4. Get licensed

    Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.

    Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
  • Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
  • Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
  • Fuel gas and oil piping (14) and hydronic heating (6) are what separate this exam from the unlimited plumbing exam.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

    Official reference list (as published by the testing agency)
    • Uniform Plumbing Code (UPC), 2018 edition, with Alaska revisions (8 AAC 63.010)
    • NFPA 54 National Fuel Gas Code, 2018 edition
    • International Mechanical Code (IMC), 2012 edition
    • Alaska Mechanical Administrator Statutes and Regulations (AS 08.40; 12 AAC 39)
    • Alaska Centralized Regulations and Statutes

    What's on the exam

    Official content outline from PSI Services (number of questions per topic):

    TopicQuestions
    General Knowledge22
    AK Statutes10
    DWV14
    Fuel Gas and Oil Piping14
    Water Piping and Backflow10
    Specialty8
    Fixtures6
    Hydronic Heating6
    Isometric Analysis10

    Exam day details

    • Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
    • Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
    • 100 scored questions in 4 hours; 70 correct (70%) to pass. Plus up to 10 unscored experimental items.
    • Scope (12 AAC 39.312): plumbing, hot water heating up to 50 psi working pressure, fuel gas and oil piping and lawn sprinklers for a single-family or duplex dwelling up to three stories.
    • Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
    • PSI may add 1 to 10 unscored experimental items, which count against your time.
    • The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
    • Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.

    Frequently asked questions

    What is on the Alaska residential plumbing and hydronic exam?

    100 questions: general knowledge 22, drainage, waste and vents 14, fuel gas and oil piping 14, water piping and backflow 10, Alaska statutes 10, isometric analysis 10, specialty plumbing 8, plumbing fixtures 6 and hydronic heating 6.

    Which books are allowed?

    The 2018 UPC, NFPA 54 (2018), the 2012 IMC and the Alaska statutes and regulations listed in the bulletin.

    Free questions with answers

    Show all 10 free questions and answers
    1. At renewal, a residential plumbing and hydronic heating administrator must complete one eight-hour continuing education workshop. Under 12 AAC 39.410(b)(3), which code coverage satisfies the requirement?

      Answer: Either the UPC adopted under AS 18.60.705 or the UMC in effect

      12 AAC 39.410(b)(3) allows either the UPC as adopted under AS 18.60.705 or the UMC in effect in the state for renewal in the residential plumbing and hydronic heating category. Unlimited plumbing (b)(2) is UPC only, and the HVAC categories (b)(1) are UMC only.

      Reference: Alaska Administrative Code 12 AAC 39, 12 AAC 39.410(b)(3)

    2. During a gas piping pressure test the gauge drops slowly and the plumber says it is probably nothing. Under UPC 1213.4, how must a drop in the gauge reading be treated?

      Answer: As a leak, unless it can be readily attributed to some other cause

      UPC 1213.4 says any reduction of test pressure shown by the gauge is deemed to indicate a leak unless the reduction can be readily attributed to some other cause. The system must withstand the test pressure with no evidence of leakage. There is no allowance for a small drop.

      Reference: 2018 Uniform Plumbing Code, Section 1213.4

    3. A hydronic boiler in a single-family home will be filled from the potable water supply, and the system uses a glycol antifreeze that is added to the loop. What backflow protection does UPC 603.5.10 call for on the boiler fill connection?

      Answer: A reduced pressure principle backflow prevention assembly

      UPC 603.5.10 requires potable connections to steam or hot water boilers to be protected by a double check valve assembly or an RP assembly per Table 603.2. Where chemicals such as glycol or inhibitors are introduced, a reduced pressure principle assembly is required. A single check or AVB is not adequate for a pressurized boiler.

      Reference: 2018 Uniform Plumbing Code, Section 603.5.10

    4. Radiant tubing will be laid in a new concrete slab-on-grade in a heated home. What minimum R-value of insulating material must be installed beneath the piping under IMC 1209.5.1?

      Answer: R-5

      IMC 1209.5.1 requires insulation with a minimum R-value of 5 beneath radiant piping in slab-on-grade applications. R-11 is the figure for suspended floors (1209.5.2), and a thermal break is also needed where the heated slab meets a foundation wall (1209.5.3).

      Reference: 2012 International Mechanical Code (Alaska), Sections 1209.5.1, 1209.5.2

    5. Under UPC 701.3.2, the threads of threaded drainage fittings must be tapped to allow what grade?

      Answer: 1/4 inch per foot

      UPC 701.3.2: the threads of drainage fittings shall be tapped to allow 1/4 inch per foot grade, matching the minimum slope for horizontal drainage piping. Recessed drainage fittings are required on screwed pipe by 701.3.1.

      Reference: 2018 Uniform Plumbing Code, Section 701.3.2

    6. A kitchen sink has a food waste disposer, and a dishwasher is added. Where may the dishwasher drain connect, under UPC 419.2?

      Answer: Only upstream of the disposer, never on its discharge side

      UPC 419.2 says no dishwasher drain shall be connected to a sink tailpiece, continuous waste or trap on the discharge side of a food waste disposer. Wye or other directional-type fittings must be used in continuous wastes receiving disposer discharge.

      Reference: 2018 Uniform Plumbing Code, Section 419.2

    7. A fuel-burning water heater is installed in a closet that opens off a bathroom. Which of the following satisfies UPC 504.1?

      Answer: A listed gasketed door with self-closing device, and outdoor combustion air

      UPC 504.1 allows a fuel-burning water heater in a closet within a bedroom or bathroom if the closet has a listed gasketed door assembly with a listed self-closing device (504.1.1, 504.1.2) with a threshold and bottom seal, and combustion air is obtained from the outdoors.

      Reference: 2018 Uniform Plumbing Code, Sections 504.1, 504.1.1, 504.1.2

    8. A gas piping plan shows these appliance inputs on one house line: furnace 80,000 Btu/h, water heater 40,000 Btu/h, range 65,000 Btu/h and dryer 35,000 Btu/h. Using UPC 1208.4.1 and natural gas at 1,000 Btu per cubic foot, what is the maximum demand in cubic feet per hour?

      Answer: 220 cubic feet per hour

      UPC 1208.4.1: the volumetric flow is the sum of the maximum inputs of the appliances served. 80,000 + 40,000 + 65,000 + 35,000 = 220,000 Btu/h, and 220,000 / 1,000 = 220 cubic feet per hour. The other values leave out appliances or double the sum.

      Reference: 2018 Uniform Plumbing Code, Section 1208.4.1

    9. Under UPC 301.2, pipe, fittings, traps, fixtures and devices used in a plumbing system must meet which general requirement?

      Answer: Be listed by an accredited agency to the standards in the code

      UPC 301.2 requires plumbing materials and devices to be listed (third-party certified) by an accredited listing agency as complying with the standards referenced in the code, and to be free from defects. Items not otherwise provided for are submitted to the AHJ for approval.

      Reference: 2018 Uniform Plumbing Code, Section 301.2

    10. A contractor wants to use a piping system that the UPC does not list, claiming it is equal in quality to a listed one. What does UPC 301.3 require before installation?

      Answer: Technical documentation of equivalency submitted to the AHJ before installation

      UPC 301.3 allows systems, methods or devices of equivalent or superior quality, but technical documentation must be submitted to the Authority Having Jurisdiction to demonstrate equivalency before installation. The AHJ may approve or disapprove for the intended purpose.

      Reference: 2018 Uniform Plumbing Code, Section 301.3

    Sources

    Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.