Alaska licensing exam

Alaska Gas Plumber (PG) Exam: Practice Test & Licensing Guide

The state-run exam for Alaska's restricted plumber PG (gas) certificate of fitness, covering fuel gas piping under the 2018 plumbing code. Open book, 70% to pass, 4-hour limit.

Questions
Not published by Alaska
Time limit
4 hours
Passing score
70%
Books
Open book

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General UPC 2018: Definitions and Administration

What work does an Alaska plumber restricted PG certificate of fitness authorize its holder to perform?

Requirements at a glance

AgencyAlaska Department of Labor and Workforce Development, Mechanical Inspection (state-run exam, not PSI)
Experience4,000 hours as an Alaska trainee, at least 2,000 in fuel gas piping (8 AAC 90.135)
ExamOpen book, 70% to pass, 4-hour maximum; the number of questions and topic weights are not published
Books allowed"Plumbing Code 2018" per the Department's list (assumed to be the 2018 UPC) (open book)
Fees$50 non-refundable application fee, then a $200 certificate fee when issued

Plumber trainees in Alaska with 4,000 hours in the trade (at least 2,000 in fuel gas piping) who apply for a restricted PG certificate of fitness to install fuel and gas piping within property lines.

How to get licensed, step by step

  1. Hold a trainee certificate

    Alaska counts experience only while you hold a trainee certificate of fitness in the trade, and only in a registered program.

    Alaska DOLWD Mechanical Inspection (opens in a new tab)

  2. Apply to Mechanical Inspection

    Send the application packet, fees and experience verification forms. Processing takes 7 to 10 business days before you can schedule.

    Alaska DOLWD Mechanical Inspection (opens in a new tab)

  3. Take the gas plumber (PG) exam

    The Department tests in Anchorage, Juneau and Fairbanks on the first and third Wednesday of each month; job centers, union halls and approved proctors cover other places. Bring a government photo ID.

    Mechanical Inspection: testing information and study guides (opens in a new tab)

  4. Retest if needed

    If you fail, wait 30 days from the date of your last exam. Results are emailed to you.

    Mechanical Inspection: testing information and study guides (opens in a new tab)

How to prepare

  • The state publishes no blueprint. Our questions are a balanced mix of the code book on the Department's study guide list, so use them to learn where things are in the book.
  • The exam is open book, so practice finding answers quickly in a tabbed copy of the code. Confirm the books and format with Mechanical Inspection at 907-269-4925.
  • The PG certificate covers fuel and gas piping within property lines. TODO(verify): the Department lists the book only as 'Plumbing Code 2018'.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

    Official reference list (as published by the testing agency)
    • Plumbing code, 2018 edition (listed by Mechanical Inspection as "Plumbing Code 2018"; the Uniform Plumbing Code 2018 is assumed)

    What's on the exam

    Estimated topic weighting. No official breakdown is published:

    TopicQuestions
    General UPC 2018: Definitions and Administration6
    General UPC 2018: Gas Piping Materials and Installation14
    General UPC 2018: Gas Piping Sizing12
    General UPC 2018: Appliance Connections and Venting12
    General UPC 2018: Testing and Inspection8
    General UPC 2018: Safety8

    Exam day details

    • Administered by State of Alaska Department of Labor and Workforce Development, Mechanical Inspection (not PSI).
    • Fee: No separate exam fee is listed. Mechanical Inspection charges a $50 non-refundable application fee and a $200 certificate fee when issued.
    • Plumber restricted PG certificate (8 AAC 90.135): 4,000 hours as a trainee, including at least 2,000 hours of fuel gas piping (2,000 hours of commercial or industrial plumbing may substitute), exam, $50 application fee and $200 certificate fee. The certificate lasts 2 years.
    • If you fail, wait 30 days from the date of your last exam before retesting.
    • State-run, open book, 70% to pass, 4-hour maximum. The Department publishes no question count or topic weights.
    • Mechanical Inspection tests in Anchorage, Juneau and Fairbanks on the first and third Wednesday of each month; job centers, union halls and approved proctors cover other places. Approval of your application packet takes 7 to 10 business days before you can schedule.

    Note: The Alaska Department of Labor does not publish the number of questions or topic weights for certificate of fitness exams. Our topic split and 60-question practice length are estimates, and a TODO(verify) remains on the exact books and scope. Check with Mechanical Inspection at 907-269-4925.

    Frequently asked questions

    How many questions are on the Alaska gas plumber exam?

    The Department of Labor does not publish a question count or topic weights. The limit is 4 hours and the pass score is 70%.

    What does a PG certificate allow?

    Installing fuel and gas piping within the property lines of the premises (8 AAC 90.135).

    Free questions with answers

    Show all 10 free questions and answers
    1. What work does an Alaska plumber restricted PG certificate of fitness authorize its holder to perform?

      Answer: Install fuel and gas piping within the property lines of the premises

      8 AAC 90.135(a) limits the PG certificate to fuel and gas piping within the property lines of the premises. It is not a full plumber license and does not cover utility mains or service lines outside the property.

      Reference: Alaska Administrative Code, 8 AAC 90.135(a)

    2. Which copper tubing types does the UPC permit for fuel gas, where the gas does not exceed the hydrogen sulfide limit?

      Answer: Type K or Type L under ASTM B88 or ASTM B280

      Section 1208.6.4.2 limits copper tubing to standard Type K or L under ASTM B88 or ASTM B280. Copper is not used where the gas contains more than an average of 0.3 grains of hydrogen sulfide per 100 scf.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Section 1208.6.4.2

    3. Corrugated stainless steel tubing used for fuel gas must be listed to which standard?

      Answer: CSA LC-1

      Section 1208.6.4.4 requires CSST to be listed in accordance with CSA LC-1. CSA Z21.24 covers appliance connectors, ASTM D2513 covers polyethylene gas pipe, and ASME B1.20.1 covers pipe threads.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Section 1208.6.4.4

    4. Use Table 1215.2(1) (Schedule 40 metallic pipe, natural gas, inlet pressure less than 2 psi, 0.5 in. w.c. drop). A single 40,000 Btu/h water heater is 20 feet from the meter. Assume 1,000 Btu per cubic foot. What is the minimum pipe size?

      Answer: 1/2 inch

      40,000 Btu/h divided by 1,000 Btu per cubic foot is 40 cubic feet per hour. In the 20-foot row, 1/2-inch pipe carries 118 cubic feet per hour, which is more than 40, so 1/2 inch is enough.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Table 1215.2(1)

    5. Using Table 1215.2(1) and Section 1215.4, a run measures 45 feet from the meter to the most remote outlet and the load is 160 cubic feet per hour. Which pipe size is selected?

      Answer: 1 inch

      Section 1215.4(2) says to use the next longer length when the exact length is not shown, so use the 50-foot row. In that row 3/4 inch carries 151, which is less than 160, so 1 inch (284) is required. The 40-foot row would give 3/4 inch (170), but 45 feet is longer than 40.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Section 1215.4

    6. A tee, a union and a connector are being installed on an appliance branch. Which arrangement matches Section 1212.6?

      Answer: Shutoff valve upstream of the connector, with a union downstream of the valve

      Where a connector is used, the valve is installed upstream of it. A union or flanged connection is provided downstream from the valve so appliance controls can be removed.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Section 1212.6

    7. A job includes a gas range, an outdoor grill, a gas fireplace and a storage water heater, none with a built-in sediment trap. Which one must have a sediment trap installed under Section 1212.9?

      Answer: The storage water heater

      Section 1212.9 requires a sediment trap where one is not built into the appliance, but exempts illuminating appliances, ranges, clothes dryers, decorative appliances for vented fireplaces, gas fireplaces and outdoor grills. The water heater is not exempt.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Section 1212.9

    8. Under Section 1213.3, a new low-pressure gas piping system is tested with air. What is the minimum test pressure and how long must it hold with no perceptible drop?

      Answer: 10 psi for at least 15 minutes

      Section 1213.3 calls for an air, CO2 or nitrogen test of not less than 10 psi gauge, held as long as the AHJ requires but in no case less than 15 minutes with no perceptible pressure drop. The 60 psi figure is for welded piping or pressures above 14 in. w.c.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Section 1213.3

    9. A CSST system will carry gas above 14 inches water column. What minimum test pressure and time does Section 1213.3 specify?

      Answer: At least 30 psi for 30 minutes

      For CSST carrying gas above 14 inches water column, the test pressure is not less than 30 psi for 30 minutes. Do not apply the 60 psi value, which is for welded piping and other piping above 14 in. w.c.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Section 1213.3

    10. Under the Alaska revision to UPC Section 1210.2.3.1 (8 AAC 63.010), where may liquefied petroleum gas piping NOT serve a gas-fired appliance?

      Answer: In a pit or basement where heavier-than-air gas might collect

      Alaska added 1210.2.3.1 to the prohibited locations section: LP-Gas piping may not serve any gas-fired appliance located in a pit or basement where heavier-than-air gas might collect to form a flammable mixture. The Alaska amendment applies even though the base UPC lacks this subsection.

      Reference: 2018 Uniform Plumbing Code (IAPMO), Section 1210.2.3.1 (8 AAC 63.010)

    Sources

    Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.