Requirements at a glance
| Agency | Alaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI |
|---|---|
| Experience | A registered Alaska general contractor (insurance, bond and business license); the exam must be passed within 12 months, then the Alaska Craftsman Home Program or an arctic engineering course within 2 years |
| Exam | 100 questions, 4 hours, 70%; not offered remotely |
| Books allowed | IRC 2018, NDS-2018, SDPWS-2015, Northern Comfort (2016), 29 CFR 1926 and the Alaska contractor statutes and regulations |
| Fee | $150 to PSI per registration, plus the CBPL application and license fees |
General contractors who want to build or alter privately owned residential structures of one to four units in Alaska (AS 08.18.025). Registered general contractors take it before getting the endorsement.
Official links
How to get licensed, step by step
Apply to the CBPL
Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
Schedule the residential endorsement exam with PSI
Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.
Schedule with PSI (residential contractor endorsement) (opens in a new tab)
Pass the exam
You need 70%. Scores are valid for 12 months toward the license.
Schedule with PSI (residential contractor endorsement) (opens in a new tab)
Get licensed
Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
- Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
- Thermal and moisture protection (advanced cold climate) and sitework, footings and foundations are the biggest Alaska-specific areas: learn frost-protected foundations, vapor retarders and cold-roof details in Northern Comfort and the IRC.
- Carpentry (12), framing (4 + 8) and wind and seismic loading (6) come from the IRC, NDS-2018 and SDPWS-2015.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Official reference list (as published by the testing agency)
- International Residential Code (IRC), 2018 edition
- ANSI/AWC NDS-2018 National Design Specification for Wood Construction
- ANSI/AF&PA SDPWS-2015 Special Design Provisions for Wind and Seismic
- Northern Comfort: Advanced Cold Climate Home Building Techniques, 2016 edition (Alaska Craftsman Home Program)
- 29 CFR Part 1926 (OSHA construction standards)
- Alaska Centralized Regulations and Statutes, and the Alaska Construction Contractor Statutes and Regulations (AS 08.18; 12 AAC 21)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Sitework, Footings and Foundations | 12 | |
| Concrete and Concrete Reinforcement | 10 | |
| Masonry | 8 | |
| General Plan Reading | 4 | |
| Carpentry General and Residential Code | 12 | |
| Adv. Cold Climate Framing | 4 | |
| AWC Framing Fundamentals | 8 | |
| Seismic and Wind Loading Fundamentals | 6 | |
| General Code | 4 | |
| Thermal and Moisture Protection General | 6 | |
| Thermal and Moisture Protections Adv. Cold Climate | 12 | |
| Equipment and Tools | 5 | |
| OSHA Safety | 6 | |
| Alaska Regulations for Residential Endorsement | 3 |
Exam day details
- Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
- Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
- 100 scored questions in 4 hours; 70 correct (70%) to pass. Plus up to 10 unscored experimental items.
- This exam is not offered by remote proctoring because of the handout; take it at a PSI test site.
- An endorsement applies to a registered general contractor. After you pass, you must complete the Alaska Craftsman Home Program or an arctic engineering course within 2 years (see the Division's rules).
- Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
- PSI may add 1 to 10 unscored experimental items, which count against your time.
- The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
- Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.
Frequently asked questions
What is on the Alaska residential contractor endorsement exam?
100 questions: sitework, footings and foundations 12, carpentry general and residential code 12, thermal and moisture protection (advanced cold climate) 12, concrete 10, masonry 8, AWC framing fundamentals 8, seismic and wind loading 6, thermal and moisture protection (general) 6, OSHA safety 6, equipment and tools 5, plan reading 4, cold-climate framing 4, general code 4 and Alaska regulations for the endorsement 3.
Does Alaska have a general contractor trade exam?
No. A general contractor registers with insurance, a bond and a business license. Only the residential endorsement for work on one to four units requires an exam.
Which books can I bring?
The 2018 IRC, NDS-2018, SDPWS-2015, 29 CFR 1926, Northern Comfort (2016) and the Alaska regulations and statutes listed in the bulletin. Use permanent tabs only.
Free questions with answers
Show all 10 free questions and answers
A driveway apron and sidewalk lie within 10 feet of a foundation wall. Where physical barriers prevent the 6-inch-in-10-feet grade, what slope must these impervious surfaces have away from the building?
Answer: 2 percent
The exception to R401.3 allows drains or swales where lot lines, walls or slopes prevent the normal grade, and impervious surfaces within 10 feet of the foundation must slope not less than 2 percent away from the building. One percent is below the minimum.
Reference: 2018 International Residential Code, R401.3, Exception
A basement wall is cast in removable forms and will be exposed to the earth. It is reinforced with No. 6 vertical bars. What is the minimum cover?
Answer: 2 inches
R404.1.3.3.7.4 sets cover for removable-form concrete exposed to earth or weather at 1 1/2 inches for No. 5 bars and smaller and 2 inches for No. 6 bars and larger. Three inches applies only where concrete is cast against the earth with no form.
Reference: 2018 International Residential Code, R404.1.3.3.7.4
A mason embeds corrugated veneer ties in the mortar joint. How much mortar cover must wall ties have from the exposed face?
Answer: 5/8 inch
R606.3.3 requires wall ties to be embedded in mortar joints with not less than 5/8 inch of mortar coverage from the exposed face. Ties for solid units must also be embedded at least 1 1/2 inches in the mortar bed.
Reference: 2018 International Residential Code, R606.3.3
What is the minimum bearing length for the end of a floor joist resting directly on a concrete foundation wall (no hanger)?
Answer: 3 inches
R502.6 requires at least 1 1/2 inches of bearing on wood or metal and at least 3 inches on masonry or concrete, or the joist must be supported by approved joist hangers.
Reference: 2018 International Residential Code, R502.6
A plan note reads "2x6 studs at 16 inches on center." Under the IRC, how are lumber dimensions in the code interpreted unless the text says otherwise?
Answer: As nominal dimensions
R301.8 states that lumber dimensions are deemed nominal unless specifically designated as actual. A nominal 2x6 actually measures about 1 1/2 by 5 1/2 inches.
Reference: 2018 International Residential Code, R301.8
A site's calculated short-period spectral response S_DS is 0.72g. Using Table R301.2.2.1.1, what Seismic Design Category applies?
Answer: D1
Table R301.2.2.1.1 assigns SDC D0 for 0.50g < S_DS <= 0.67g, D1 for 0.67g < S_DS <= 0.83g, and D2 for 0.83g < S_DS <= 1.25g. A value of 0.72g falls in the D1 band.
Reference: 2018 International Residential Code, Table R301.2.2.1.1
A crew applies No. 15 asphalt felt horizontally as the water-resistive barrier on exterior wall sheathing. What laps does the IRC require?
Answer: Upper layer over the lower by at least 2 inches; vertical joints lapped at least 6 inches
R703.2 requires one layer of No. 15 felt applied horizontally with the upper layer lapped over the lower not less than 2 inches, and joints lapped not less than 6 inches. Shingle-style lapping (upper over lower) sheds water out of the wall.
Reference: 2018 International Residential Code, R703.2
A house with a 6:12 roof has a 16-inch horizontal eave overhang. Measured horizontally from the eave edge, how far up the roof must the ice barrier reach to meet R905.1.2?
Answer: 40 inches
The barrier must reach a point 24 inches inside the exterior wall line. The overhang adds 16 inches beyond the wall, so the horizontal run from the eave edge is 16 + 24 = 40 inches. The 24-inch answer ignores the overhang; 16 inches only reaches the wall line.
Reference: 2018 International Residential Code, R905.1.2
A worker wants to blow sawdust off a work surface with compressed air. OSHA allows this only with effective chip guarding and PPE, and only where the air pressure is reduced to less than what value?
Answer: 30 psi
29 CFR 1926.302(b)(4) prohibits compressed air for cleaning unless it is reduced to less than 30 psi and used with effective chip guarding and personal protective equipment. The 100-psi value is the muzzle-safety threshold for pneumatic nailers.
Reference: 29 CFR Part 1926 (OSHA construction standards), 1926.302(b)(4)
A portable ladder is used to reach a roof edge. How far must the side rails extend above the upper landing surface?
Answer: 3 feet
29 CFR 1926.1053(b)(1) requires ladder side rails to extend at least 3 feet above the upper landing surface, or the ladder must be secured at the top with a grab rail provided when that extension is not possible.
Reference: 29 CFR Part 1926 (OSHA construction standards), 1926.1053(b)(1)
Sources
- PSI: Alaska Contractor Examination Candidate Information Bulletin (updated 10/15/2026) (opens in a new tab)
- Alaska Division of Corporations, Business and Professional Licensing (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.