Requirements at a glance
| Agency | Wisconsin Department of Safety and Professional Services (DSPS) |
|---|---|
| Experience | No experience requirement (SPS 305.63); exam waived for a Wisconsin HVAC Qualifier or Commercial Building Inspector |
| Exam | 75 questions, 3 hours, 70% to pass |
| Books allowed | One binder (SPS 305, SPS 320 to 323 and printed notes) |
| Fees | $90 at Pearson VUE ($25 at a DSPS site), plus the credential fee ($40 plus $15 application, 24 CE hours, renews June 30) |
Municipal and contract inspectors applying to DSPS for a UDC HVAC inspector credential (SPS 305.63). There is no experience requirement; you apply, pay and pass.
Official links
- Wisconsin Department of Safety and Professional Services (DSPS) (opens in a new tab)
- DSPS: trades exam information and fee schedule (opens in a new tab)
- Pearson VUE: Wisconsin DSPS Trades candidate handbook (PDF) (opens in a new tab)
- Wisconsin Admin. Code chapter SPS 320 (UDC administration and enforcement) (opens in a new tab)
- Wisconsin Admin. Code chapter SPS 323 (UDC HVAC) (opens in a new tab)
- DSPS permitted trades exam materials (PDF) (opens in a new tab)
How to get licensed, step by step
Apply to DSPS
Apply in LicensE for the UDC HVAC inspector credential, then pay and pass the exam.
Wisconsin Department of Safety and Professional Services (DSPS) (opens in a new tab)LicensE: apply for your credential (opens in a new tab)
Schedule your exam
Once your qualifications are met, DSPS sends an exam authorization. Schedule with Pearson VUE or, for electrical exams, a DSPS exam site. If you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.
DSPS: trades exam information and fee schedule (opens in a new tab)Pearson VUE: Wisconsin DSPS Trades candidate handbook (PDF) (opens in a new tab)
Take the exam
75 questions, 3 hours, 70% to pass. Bring only the items DSPS lists; sticky notes, loose paper and removable tabs are not allowed.
Wisconsin Admin. Code chapter SPS 320 (UDC administration and enforcement) (opens in a new tab)Wisconsin Admin. Code chapter SPS 323 (UDC HVAC) (opens in a new tab)DSPS permitted trades exam materials (PDF) (opens in a new tab)
Results and licensing
After you pass, wait 2 days, then submit your license application in LicensE. DSPS sends one exam authorization at a time, so a retake needs a new authorization. On two-part exams a failed part is retaken alone and all parts must be passed within 1 year.
How to prepare
- Concentrate on SPS 323: heating equipment, combustion air, ductwork, chimneys and vents, and fuel supply for one- and two-family dwellings.
- Our bank follows the Wisconsin SPS text only; the UDC Appendix is not freely readable.
- Every Wisconsin trades exam is open book, but DSPS limits what you can bring (a binder plus the listed books), and tabs must come with a bound book. Practice finding answers fast in your own binder.
- DSPS publishes no content outline or topic weights, so our topic split is an estimate built from the reference lists DSPS prints. Counts and times come from DSPS's exam table.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the UDC (SPS 320 to 325). Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Wisconsin Uniform Dwelling Code: Wisconsin Admin. Code SPS 305 and SPS 320 to 325Essential
Put these chapters in your binder. The UDC Appendix is sold by DSPS and is not freely readable.
Official reference list (as published by the testing agency)
- One binder with Wis. Admin. Code SPS 305, SPS 320, SPS 321, SPS 322 and SPS 323 and your printed notes
- Printed notes go in a three-ring binder; practice exams do not count as notes
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| UDC Administration and Inspector Credentials (SPS 305.63, SPS 320) | 10 | |
| Heating Equipment: Selection, Location and Safety Controls (SPS 323.02 to 323.065) | 20 | |
| Air Distribution and Ductwork (SPS 323.07 and 323.08) | 16 | |
| Chimneys, Vents and Connectors (SPS 323.11 to 323.156) | 20 | |
| Fuel Supply, Equipment Location and Operation (SPS 323.16 to 323.18) | 12 | |
| Energy Conservation: Systems and Equipment (SPS 322.40 to 322.49) | 14 | |
| Construction Standards Affecting HVAC (SPS 321) | 8 |
Exam day details
- Administered by the Wisconsin Department of Safety and Professional Services (DSPS); exams are given by Pearson VUE or at a DSPS exam site.
- Fee: $90 at Pearson VUE ($25 at a DSPS exam site). The credential application fee is separate.
- 75 questions in 3 hours (DSPS exam table, not checked against Pearson); open book; 70% to pass.
- The exam is waived if you hold a Wisconsin HVAC Qualifier or Commercial Building Inspector credential.
- Our questions follow the Wisconsin SPS text. The UDC Appendix, NFPA 13D and the international model codes are not freely readable, so they are not in our bank.
- Open book: bring one binder (three-hole-punched printed notes and printed code), plus the other references DSPS lists for your exam. Loose paper, removable tabs, sticky notes and paperclips are not allowed; practice exams do not count as notes.
- You can test at a Pearson VUE center or a DSPS exam site, but once you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.
- The passing score is 70%. For two-part exams you need 70% in each part, a failed part is retaken alone, and all parts must be passed within 1 year (SPS 305.09(6)).
- DSPS sends one exam authorization at a time. After you pass, wait 2 days, then apply for the license in LicensE.
- DSPS publishes no content outline or topic weights (SPS 305.09(5) says the exams are based on a job analysis), so our topic split is an estimate built from the reference lists DSPS prints.
Note: DSPS publishes the question counts, time limits and permitted references but no content outline or topic weights, so our topic split is an estimate. Counts come from DSPS's exam table and were not checked against Pearson.
Frequently asked questions
Who can skip the UDC HVAC inspector exam?
Holders of a Wisconsin HVAC Qualifier or Commercial Building Inspector credential.
Which rules does it cover?
SPS 323 (dwelling heating, ventilating and air conditioning), with SPS 320 administration and the related parts of SPS 321 and SPS 322.
How much does it cost?
$90 at Pearson VUE or $25 at a DSPS exam site. The credential is $40 plus a $15 application fee.
Free questions with answers
Show all 10 free questions and answers
A certified UDC-HVAC inspector may inspect one- and 2-family dwellings for the purpose of administering and enforcing which chapter?
Answer: Chapter SPS 323, Heating, Ventilating and Air Conditioning
SPS 305.63(1)(b)3. limits the certified UDC-HVAC inspector to ch. SPS 323. Chapters 320 to 322 belong to the UDC-construction inspector, 316 and 324 to the electrical inspectors, and 325, 382 and 384 to the plumbing inspectors.
Reference: Wis. Admin. Code SPS 305, SPS 305.63(1)(b)3.
A dwelling has three intermittent exhaust fans rated 50 cfm, 80 cfm and 90 cfm, and makeup air comes through a passive intake duct. Under SPS 323.02(3)(b)2., what is the minimum capacity the passive intake duct must provide?
Answer: 88 cfm
SPS 323.02(3)(b)2. requires a passive intake duct to be sized to provide at least 40% of the total air that would be exhausted with all intermittent exhaust ventilation operating at once. Total exhaust 50 + 80 + 90 = 220 cfm; 220 x 0.40 = 88 cfm. The 220 cfm answer assumes 100% makeup, and 132 and 110 use 60% and 50%.
Reference: Wis. Admin. Code SPS 323, SPS 323.02(3)(b)2.
Using Table 323.07, what is the maximum velocity allowed through a grille or opening in a dwelling air distribution system?
Answer: 600 feet per minute
Table 323.07 lists a maximum of 600 fpm (minimum 400 fpm) for grilles or openings. 300 fpm is the maximum for return air door undercuts and door or wall louvers, and 800 fpm is the maximum for the outdoor intake. Grilles are held low to limit noise and drafts.
Reference: Wis. Admin. Code SPS 323, Table 323.07
Using Table 323.07, what is the maximum velocity for a return air door undercut?
Answer: 300 feet per minute
Table 323.07 gives return air door undercuts a minimum of 200 fpm and a maximum of 300 fpm. 200 fpm is the minimum, not the maximum, and 600 fpm applies to grilles or openings. The 0.10 in. w.g. per 100 ft loss limit applies to this row as well.
Reference: Wis. Admin. Code SPS 323, Table 323.07
How must all heating appliances that use solid, liquid or gas fuels be vented under SPS 323.11(1)?
Answer: To the outside by a factory-built all-fuel chimney, masonry chimney or other listed venting system
SPS 323.11(1) requires every heating appliance burning solid, liquid or gas fuel to be vented outside by an all-fuel factory-built chimney, a masonry chimney or another listed venting system designed to remove combustion products. Venting into an attic, crawl space or shared shaft would discharge combustion gases inside the building.
Reference: Wis. Admin. Code SPS 323, SPS 323.11(1)
A direct-vent appliance with an input of 40,000 Btu/h has its vent terminal near an air opening into the building. What is the minimum distance from the terminal to that opening under SPS 323.14(3)(c) to (e)?
Answer: 9 inches
SPS 323.14(3) sets 6 inches for direct-vent inputs of 10,000 Btu/h or less, 9 inches for inputs over 10,000 up to 50,000 Btu/h, and 12 inches for inputs over 50,000 Btu/h. A 40,000 Btu/h unit is in the middle band. The bottom of the terminal and the air intake must also be at least 12 inches above grade (par. (f)).
Reference: Wis. Admin. Code SPS 323, SPS 323.14(3)(c) to (e)
What is the maximum oil storage allowed inside a dwelling unit under SPS 323.16(2)(a)?
Answer: 550 gallons in one tank, or not more than 275 gallons in each of 2 cross-connected tanks
SPS 323.16(2)(a) caps oil storage inside a dwelling unit at 550 gallons in one tank, or not more than 275 gallons in each of 2 tanks cross-connected to a single burner. Par. (b) adds that inside tanks sit at the same level as the burner they serve.
Reference: Wis. Admin. Code SPS 323, SPS 323.16(2)(a)
What heating design temperature does SPS 322.40(2) require for areas of a dwelling other than unheated, non-habitable basements?
Answer: 70 degrees F
SPS 322.40(2) uses a heating design indoor temperature of 70 F for all areas other than unheated, non-habitable basements, which use a design temperature of less than 50 F. These indoor temperatures are used for the total dwelling heat loss and for sizing the heating equipment.
Reference: Wis. Admin. Code SPS 322, SPS 322.40(2)
An installer proposes to seal the joints of a metal supply duct in an unconditioned attic. Which material is acceptable under SPS 322.43?
Answer: Mastic installed per the manufacturer's instructions
SPS 322.43(2) allows welds, gaskets, mastics, mastic-plus-embedded-fabric systems or tapes installed to the manufacturer's instructions, and sub. (6) prohibits tapes with rubber-based adhesives. The note says standard duct tape has a rubber adhesive and does not comply. Painting over it does not change that.
Reference: Wis. Admin. Code SPS 322, SPS 322.43(2) and (6)
When more than one flue is contained in the same masonry chimney, what does SPS 321.30(3) require between the individual flues?
Answer: A masonry separation at least 4 inches thick, with flue lining joints staggered at least 7 inches
SPS 321.30(3) requires a nominal 4 inch masonry separation between flues in the same chimney and staggering of adjacent flue liner joints by at least 7 inches. Aligned joints would let a failure at one joint expose the neighboring flue.
Reference: Wis. Admin. Code SPS 321, SPS 321.30(3)
Sources
- DSPS: trades exam information and fee schedule (opens in a new tab)
- Pearson VUE: Wisconsin DSPS Trades candidate handbook (opens in a new tab)
- Wisconsin Admin. Code chapter SPS 320 (UDC administration and enforcement) (opens in a new tab)
- Wisconsin Admin. Code chapter SPS 323 (UDC heating, ventilating and air conditioning) (opens in a new tab)
Questions last verified November 11, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.