West Virginia licensing exam

West Virginia Journeyman Plumber Exam: Practice Test & Licensing Guide

The Prov exam for West Virginia journeyman plumbers: 80 open-book questions on water supply, drain, waste and vent systems, fuel gas, isometrics and plumbing math.

Questions
80
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Water Heaters

An installer builds a relief valve discharge line with a drop elbow, a union, a male threaded adapter at the termination and a tee that also picks up a second heater's relief valve. Which features does Section 504.6 prohibit?

Requirements at a glance

AgencyWest Virginia Division of Labor (plumber licensing); exams by Prov
ExamJourneyman plumber exam: 80 questions, 3 hours, 70%
Books allowedIPC 2018, IFGC 2018, Plumbing Basics for Contractors 4th Edition
Fees$59.95 per Prov exam; $75 master or journeyman license, renewed annually (42 CSR 32, 9.1)

Plumbers applying to the West Virginia Division of Labor for a journeyman plumber license. Plumbers-in-training take no exam.

How to get licensed, step by step

  1. Check which license you need

    The Division of Labor licenses master and journeyman plumbers; plumbers-in-training take no exam. Call (304) 558-7890 if you are unsure which exam applies; Prov cannot refund the wrong exam.

    Division of Labor candidate bulletin (Prov) (opens in a new tab)West Virginia Code 21-14 (Plumbers) (opens in a new tab)

  2. Register with Prov

    Register at provexam.com or call (866) 720-7768. Test at a Prov center or at home with remote proctoring.

    Register for your exam with Prov (opens in a new tab)Division of Labor candidate bulletin (Prov) (opens in a new tab)

  3. Take the exam

    3 hours, 70% to pass, and you see your score at the end. There is no waiting period before a retake.

    Division of Labor candidate bulletin (Prov) (opens in a new tab)

  4. Get licensed

    Send your result and the license fee to the Division of Labor.

    West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)

How to prepare

  • The bulletin lists the 2018 IPC and IFGC. Tab the drain, waste and vent, water supply and fuel gas chapters.
  • Water supply (11) and drain, waste and vent (11) are the largest sections; fuel gas and plumbing math are 8 each.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Plumbing Code 2018 (ICC)
  • International Fuel Gas Code 2018 (ICC)
  • Plumbing Basics for Contractors, 4th Edition, 2021 (Pearson)

What's on the exam

Official content outline from Prov, Inc. (number of questions per topic):

TopicQuestions
General Knowledge8
Fixtures & Fittings5
Storm Drainage5
Fuel Gas Systems8
Safety6
Isometrics7
Water Supply and Distribution11
Water Heaters6
Drain, Waste and Vent Systems11
Plumbing Math8
Plumbing Tools5

Exam day details

  • Administered by Prov, Inc. for the West Virginia Division of Labor.
  • Fee: $59.95 to Prov per exam, whether first try or retake. Licensing board application and license fees are separate.
  • 80 questions in 3 hours; 70% to pass.
  • Open book: bring the references the bulletin lists (any older or newer edition of the same book is allowed, but the exam is scored on the edition shown in the bulletin). Prepare them only by highlighting and attaching permanent tabs; handwritten notes, moveable tabs and sticky notes are not allowed.
  • Computer-based at a Prov testing center or at home with Examroom remote proctoring. Only a simple 4-function calculator is allowed.
  • You get your score at the testing center. There is no waiting period between attempts and no limit on retakes; retake fees equal the first-try fee.
  • Change or cancel at least 3 business days before your test date or you forfeit the fee. You can ask for a review of your exam after failing it at least twice with a score within 10 points of 70%.

Note: The Prov bulletin lists the 2018 IPC and IFGC, the editions in the West Virginia State Building Code (87 CSR 4). Questions follow the 2018 editions.

Frequently asked questions

What's on the West Virginia journeyman plumber exam?

80 questions: water supply and distribution 11, drain, waste and vent systems 11, general knowledge 8, fuel gas systems 8, plumbing math 8, isometrics 7, safety 6, water heaters 6, fixtures and fittings 5, storm drainage 5 and plumbing tools 5.

Is the exam open book?

Yes. You may bring the IPC 2018, IFGC 2018 and Plumbing Basics for Contractors with highlighting and permanent tabs, but no handwritten notes or sticky notes.

How much does the exam cost?

$59.95 to Prov per attempt, with no waiting period between retakes. License fees are separate.

Free questions with answers

Show all 10 free questions and answers
  1. An installer builds a relief valve discharge line with a drop elbow, a union, a male threaded adapter at the termination and a tee that also picks up a second heater's relief valve. Which features does Section 504.6 prohibit?

    Answer: The threaded end, the tee, and sharing the line with another relief device

    Discharge piping must serve a single relief device, must not have valves or tee fittings, and must not end in a threaded connection. The drop elbow and the union are not listed prohibitions, so the three features named in the key all fail.

    Reference: 2018 International Plumbing Code, Section 504.6

  2. A natural gas system (1,000 Btu/ft3, under 2 psi, 0.5 in. w.c. drop) has a longest run of 40 feet. It serves a 250,000 Btu/h boiler, a 150,000 Btu/h furnace and a 100,000 Btu/h water heater. Using Table 402.4(2) for Schedule 40 pipe, what is the smallest pipe for the run? (Capacities at 40 ft: 1 in = 320, 1-1/4 in = 657, 1-1/2 in = 985, 2 in = 1,900 cfh.)

    Answer: 1-1/4 inch

    Section 402.2 sizes pipe on the sum of the appliance inputs: 250,000 + 150,000 + 100,000 = 500,000 Btu/h, which is 500 cfh at 1,000 Btu/ft3. At the 40 ft row, 1 inch carries only 320 cfh, while 1-1/4 inch carries 657 cfh, the first size that is enough.

    Reference: 2018 International Fuel Gas Code, Section 402.2; Table 402.4(2)

  3. A water service line shares a trench with a building sewer made of a material that is not listed in Table 702.2. What horizontal separation does the IPC require between them?

    Answer: At least 5 feet of undisturbed or compacted earth

    Section 603.2 permits a shared trench when the sewer is made of Table 702.2 materials. If it is not, the pipes must be separated horizontally by 5 feet of undisturbed or compacted earth. The older 10-foot figure is not the 2018 IPC rule.

    Reference: 2018 International Plumbing Code, Section 603.2

  4. Using Table 704.1, what is the minimum slope for a 4-inch horizontal drainage pipe?

    Answer: 1/8 inch per foot

    Table 704.1 requires 1/4 inch per foot for pipes 2-1/2 inches or smaller, 1/8 inch per foot for 3 to 6 inches, and 1/16 inch per foot for 8 inches and larger. Piping upstream of a grease interceptor needs 1/4 inch per foot regardless of size.

    Reference: 2018 International Plumbing Code, Table 704.1

  5. A new lavatory will be set beside a side wall. What is the minimum distance from the centerline of the lavatory to that wall, and the minimum clear space in front of it?

    Answer: 15 inches to the wall and 21 inches in front

    Section 405.3.1 requires water closets, urinals, lavatories and bidets to be at least 15 inches from center to any side wall or obstruction, with at least 21 inches of clearance in front. Adjacent fixtures without partitions are 30 inches center to center.

    Reference: 2018 International Plumbing Code, Section 405.3.1

  6. May a drain from a floor drain in a basement be connected to the building storm drain?

    Answer: No, floor drains shall not be connected to a storm drain

    Section 1104.2 states that floor drains shall not be connected to a storm drain. Section 1104.1 likewise forbids using conductors as soil, waste or vent pipes or the reverse, and Section 1101.3 bars storm water from sanitary-only sewers.

    Reference: 2018 International Plumbing Code, Sections 1104.2 and 1101.3

  7. A journeyman plumber's state license expired 100 days ago and he has not renewed. What does the rule say?

    Answer: The license cannot be renewed because it has been expired 90 days or more

    42 CSR 32 section 6.4 sets a $25 late fee when the renewal is received or postmarked more than 15 days after expiration, but a license that has been expired for 90 days or more cannot be renewed. At 100 days the late-fee option is gone.

    Reference: Legislative Rule 42 CSR 32 (Supervision of Plumbing Work), Section 6.4

  8. A trench is 5 feet deep. How must employees be able to get out of it?

    Answer: A ladder, stairway or ramp within 25 feet of lateral travel of any worker

    1926.651(c)(2) requires a stairway, ladder, ramp or other safe means of egress in trenches 4 feet or more in depth so that employees need no more than 25 feet of lateral travel to reach it.

    Reference: 29 CFR 1926 Subpart P (OSHA excavation standard), 29 CFR 1926.651(c)(2)

  9. How many gallons does a 100-foot run of 2-inch inside-diameter pipe hold? (231 cubic inches per gallon)

    Answer: 16.3 gallons

    Area = pi x r^2 = 3.1416 x 1^2 = 3.1416 sq in. Volume = 3.1416 x 1,200 in = 3,770 cu in. 3,770 / 231 = 16.3 gal. Using the diameter as the radius gives 65.3 gallons; multiplying 16.3 by 7.48 wrongly gives 122.1.

    Reference: General trade practice: volume of a pipe, Volume = pi x r^2 x length; 231 cu in per gallon

  10. On a standard plumbing isometric drawing, how are vertical pipes (risers and drops) drawn?

    Answer: As vertical lines on the page

    In an isometric drawing the vertical axis is drawn vertical, and the two horizontal axes are drawn at 30 degrees above the horizontal baseline, 120 degrees apart. Lengths along each axis are drawn to scale.

    Reference: General trade practice: isometric drawing, Isometric axes: one vertical, two at 30 degrees

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.