Requirements at a glance
| Agency | West Virginia Office of the State Fire Marshal, Regulatory and Licensing Division |
|---|---|
| Experience | Age 18, plus 1 year as an assistant/helper, a registered USDOL apprenticeship, or a 1,080-hour approved vocational electrical program (103 CSR 5, 4.2) |
| Exam | Journeyman electrician exam: 50 multiple choice plus 5 calculations, 4 hours, 70%. Paper, in person, open book |
| Books allowed | NEC (2023 per the State Fire Marshal; some forms still say 2020, so confirm) with tabs |
| Fees | $25 non-refundable application review fee (103 CSR 5, 5.2.2); $50 a year license fee (103 CSR 5, 7.2) |
Electricians applying to the West Virginia State Fire Marshal for a journeyman license, which lets you do electrical work under a master electrician.
Official links
How to get licensed, step by step
Confirm you qualify
You must be 18 (a student in an approved vocational electrical program may test earlier and be licensed at 18) and meet the experience for your level.
State Fire Marshal: Regulatory and Licensing Division (opens in a new tab)West Virginia Code 29-3B (Electricians) (opens in a new tab)
Apply to the State Fire Marshal
Send the application and the $25 review fee at least 10 working days before the exam date you want. You receive a written authorization form to bring to the exam.
State Fire Marshal: Regulatory and Licensing Division (opens in a new tab)
Sit the in-person exam
Exams are on set dates in Charleston, Beckley, Clarksburg, Martinsburg and Wellsburg; see the 2027 schedule on the State Fire Marshal's page. You forfeit the fee if you no-show without 24 hours' notice.
State Fire Marshal: Regulatory and Licensing Division (opens in a new tab)
Get licensed
After you pass with 70%, send the license fee and the State Fire Marshal issues your license.
State Fire Marshal: Regulatory and Licensing Division (opens in a new tab)
How to prepare
- The State Fire Marshal publishes no outline, only the format: 50 multiple-choice questions and 5 calculations in 4 hours. Practice both, and do the calculations first or last on a set plan so time doesn't run out.
- Tab Articles 90, 100, 110, 210, 215, 220, 230, 240, 250, 310, 314, 430 and Chapter 9 of your NEC, and the Annex tables you use for calculations.
- Journeyman questions center on installation: wiring methods, branch circuits, grounding, boxes and conductor ampacity.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 EditionEssential
Allowed in the exam room. The State Fire Marshal says 2023 from January 1, 2026 (some forms still say 2020). Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (2023 edition per the State Fire Marshal; see the edition note)
- Ugly's Electrical References and similar field references with tabs are reported as allowed; check your exam authorization.
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 7 | |
| Wiring and Protection | 12 | |
| Wiring Methods and Materials | 14 | |
| Equipment for General Use | 6 | |
| Motors and Controls | 4 | |
| Special Occupancies and Equipment | 7 | |
| Calculations | 5 |
Exam day details
- Administered by West Virginia Office of the State Fire Marshal.
- Fee: $25 non-refundable application review fee to the State Fire Marshal (103 CSR 5, 5.2.2). After you pass, the license fee is $50 a year (103 CSR 5, 7.2).
- 50 multiple-choice questions plus 5 calculation problems in 4 hours; 70% to pass.
- Journeyman applicants need 1 year as an assistant/helper under a master or journeyman, a registered USDOL electrical apprenticeship, or a 1,080-hour approved vocational electrical program (103 CSR 5, 4.2).
- This is a State Fire Marshal exam, not a Prov exam. It is given on paper in person at Charleston, Beckley, Clarksburg, Martinsburg and Wellsburg on published dates (the 2027 schedule has six Charleston dates).
- Apply to the State Fire Marshal at least 10 working days before the exam date; you must bring the written authorization form you receive. You must be 18 (a student in an approved vocational electrical program may test earlier and be licensed at 18).
- 70% is required to pass (103 CSR 5, 5.13). The exam is open book. The SFMO does not publish a content outline; our topic weights are an estimate based on the NEC.
- If you do not appear you forfeit the exam fee unless you give 24 hours notice, and you pay again when you reapply.
Note: The State Fire Marshal's electrical page says all electrical exams use the 2023 NEC from January 1, 2026, but its application form and some other pages still say 2020. Our questions follow the 2023 NEC. Confirm the edition with the State Fire Marshal before you test. The SFMO publishes no exam outline, so the topic weights shown are our estimate.
Frequently asked questions
Who gives the West Virginia journeyman electrician exam?
The Office of the State Fire Marshal, in person on paper at set dates in Charleston, Beckley, Clarksburg, Martinsburg and Wellsburg. It is not a Prov or PSI exam.
How many questions are on the exam and what score passes?
50 multiple-choice questions and 5 calculation problems in 4 hours. You need at least 70% (103 CSR 5, 5.13).
Which NEC edition does West Virginia use?
The State Fire Marshal says all electrical exams use the 2023 NEC from January 1, 2026, though some forms still say 2020. Confirm with the State Fire Marshal before you test.
Free questions with answers
Show all 10 free questions and answers
A 240-volt circuit supplies a resistive load with a resistance of 16 ohms. How much current flows in the circuit?
Answer: 15 A
Ohm's law gives I = E / R = 240 / 16 = 15 A. Multiplying the voltage by the resistance (3,840) and inverting the fraction (0.067) are common slips, and 30 A would result from using 480 V.
Reference: General trade practice: Ohm's law, Ohm's law (E = I x R)
Two resistors of 12 ohms and 4 ohms are connected in parallel. What is the total resistance?
Answer: 3 ohms
For two resistors in parallel, R = (R1 x R2) / (R1 + R2) = (12 x 4) / 16 = 3 ohms. The total is always less than the smallest branch. 16 ohms is the series total and 8 ohms is the simple average.
Reference: General trade practice: parallel resistance, Parallel resistance
Under 210.8(A) of the 2023 NEC, which of these 125-volt receptacles in a new one-family dwelling must have GFCI protection for personnel?
Answer: A receptacle in the laundry area, 12 ft from the nearest sink
Section 210.8(A) lists laundry areas among the required dwelling-unit locations, along with bathrooms, garages, outdoors, crawl spaces, basements, kitchens, areas with sinks and food preparation, and indoor damp and wet locations. Bedroom, hallway and dining-room receptacles are not listed there (they are covered by AFCI protection in 210.12 instead).
Reference: NFPA 70, National Electrical Code (NEC), 2023 edition, 210.8(A)(11)
A receptacle in a dwelling is 5 ft from the top inside edge of a sink bowl in a utility area. Under 210.8(A), how close to a sink does a receptacle have to be before GFCI protection is required?
Answer: Within 6 ft of the top inside edge of the bowl
Section 210.8(A)(8) requires GFCI protection for receptacles within 1.8 m (6 ft) of the top inside edge of the bowl of a sink. A receptacle 5 ft away is therefore covered. The 3, 4 and 10 ft figures are not in the rule.
Reference: NFPA 70, National Electrical Code (NEC), 2023 edition, 210.8(A)(8)
Type FMC (flexible metal conduit) is installed without any listed fittings that allow longer spacing. What are the maximum distance from a box to the first support and the maximum spacing between supports?
Answer: 12 in. from the box; 4 1/2 ft between supports
Section 348.30(A) requires FMC to be fastened within 300 mm (12 in.) of each box or termination and supported at intervals not exceeding 1.4 m (4 1/2 ft). The 3 ft and 10 ft values apply to EMT and rigid metal conduit.
Reference: NFPA 70, National Electrical Code (NEC), 2023 edition, 348.30(A)
A pull box has an angle pull. A trade size 3 raceway and a trade size 2 raceway enter the same wall in one row. What is the minimum distance from those entries to the opposite wall?
Answer: 20 in.
For angle pulls, 314.28(A)(2) requires six times the trade size of the largest raceway in the row, plus the sum of the other raceways in the same row on that wall: (6 x 3) + 2 = 20 in. 18 in. leaves out the 2-in. entry, and 24 in. applies eight times 3 (the straight-pull rule).
Reference: NFPA 70, National Electrical Code (NEC), 2023 edition, 314.28(A)(2)
A 20-ampere, 125-volt receptacle is installed outdoors in a wet location, where it will have a portable tool plugged in for long periods. Which enclosure does 406.9(B)(1) require?
Answer: One that is weatherproof whether or not a plug is inserted
Section 406.9(B)(1) requires receptacles of 15 and 20 amperes, 125 and 250 volts, in a wet location to have an enclosure that is weatherproof with or without the plug inserted, such as an in-use (bubble) cover. A cover that is weatherproof only when closed meets 406.9(A) for damp locations, not wet locations.
Reference: NFPA 70, National Electrical Code (NEC), 2023 edition, 406.9(B)(1)
When sizing branch-circuit conductors and short-circuit and ground-fault protection for a general-purpose induction motor, which full-load current does 430.6(A)(1) tell you to use?
Answer: The value from Table 430.248 or Table 430.250, not the nameplate
Section 430.6(A)(1) requires the full-load current values in Tables 430.247 through 430.250 to be used, instead of the nameplate, to determine conductor ampacity and the ratings of disconnects, controllers and short-circuit and ground-fault protection. Overload protection is the exception: 430.6(A)(2) uses the nameplate current.
Reference: NFPA 70, National Electrical Code (NEC), 2023 edition, 430.6(A)(1) and (A)(2)
What does 702.5(A) require of transfer equipment used with an optional standby system?
Answer: It must be installed to prevent inadvertent interconnection of all sources
Section 702.5(A) requires interconnection or transfer equipment for all standby systems, listed and installed so as to prevent the inadvertent interconnection of all sources of supply in any operation of the equipment. The 10-second figure is an emergency system requirement in 700.12, not a rule for optional standby transfer equipment.
Reference: NFPA 70, National Electrical Code (NEC), 2023 edition, 702.5(A)
A three-phase, 208-volt feeder load draws 16 amperes through 12 AWG copper (K = 12.9, 6,530 circular mils) for a one-way distance of 150 ft. What is the approximate voltage drop as a percentage of 208 volts?
Answer: 3.95 percent
For three-phase, VD = 1.732 x K x I x L / CM = 1.732 x 12.9 x 16 x 150 / 6,530 = 8.21 V. Percent drop = 8.21 / 208 = 3.95 percent. 4.56 percent uses 2 instead of 1.732 (the single-phase factor), 6.84 percent divides by 120 V, and 2.28 percent leaves out the 1.732 factor (4.74 V / 208).
Reference: NFPA 70, National Electrical Code (NEC), 2023 edition, 210.19 Informational Note and 215.2(A)(2) Informational Note No. 2 (voltage drop), with Chapter 9, Table 8
Sources
- West Virginia State Fire Marshal: Regulatory and Licensing Division (opens in a new tab)
- West Virginia Code Chapter 29, Article 3B (Electricians) (opens in a new tab)
- 103 CSR 5: Electricians licensing rule (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.