Requirements at a glance
| Agency | West Virginia Contractor Licensing Board (Division of Labor); exams by Prov |
|---|---|
| When you need it | Contracting work of $5,000 or more residential or $25,000 or more commercial (W. Va. Code 30-42-3) |
| Exams | HVAC contractor exam: 80 questions, 3 hours, 70%, plus the Contractor Licensing Act exam |
| Books allowed | IMC 2021, HVAC Basics for Contractors 3rd Edition, SMACNA Residential Comfort System Installation Standards 2016 |
| Fees | $59.95 per Prov exam; $90 annual Board license fee (28 CSR 2, 5.5) |
Businesses applying for the West Virginia Heating, Ventilating and Cooling Contractor classification: installing, repairing, servicing or altering HVAC equipment in residential and commercial structures. This is separate from the Division of Labor HVAC technician exams.
Official links
- West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)
- Contractor Licensing Board candidate bulletin (Prov) (opens in a new tab)
- Register for your exam with Prov (opens in a new tab)
- West Virginia Code 30-42 (Contractor Licensing Act) (opens in a new tab)
- 28 CSR 2 (Contractor Licensing Board rule) (opens in a new tab)
How to get licensed, step by step
Pick your classification
Every contractor passes the Contractor Licensing Act exam plus a trade exam where one exists. Check the classification definitions in 28 CSR 2.
West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)28 CSR 2 (Contractor Licensing Board rule) (opens in a new tab)
Apply to the Board
Apply through the Contractor Licensing Board at the Division of Labor, (304) 558-7890.
West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)
Take your exams with Prov
Register at provexam.com or call (866) 720-7768. 3 hours per exam, 70% to pass, score on the spot, no waiting period before a retake.
Register for your exam with Prov (opens in a new tab)Contractor Licensing Board candidate bulletin (Prov) (opens in a new tab)
Get licensed
Send your results and the license fee to the Board.
West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)West Virginia Code 30-42 (Contractor Licensing Act) (opens in a new tab)
How to prepare
- The Board bulletin lists the 2021 IMC (70% of questions) although West Virginia adopts the 2018 edition. General knowledge is 30 of 80 questions.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Mechanical Code (IMC), 2021 EditionEssential
Listed in the Board bulletin for the HVAC contractor exam (about 70% of questions), although West Virginia adopts the 2018 edition. Older or newer editions are allowed in the room.
ICC store (opens in a new tab)Read free (ICC Digital Codes) (opens in a new tab)
HVAC Basics for Contractors, 3rd Edition; SMACNA Residential Comfort System Installation Standards Manual, 2016
Allowed in the exam room. About 14% each of the HVAC contractor exam.
Official reference list (as published by the testing agency)
- International Mechanical Code 2021 (ICC), about 70% of questions
- HVAC Basics for Contractors, 3rd Edition (Pearson), about 14%
- SMACNA Residential Comfort System Installation Standards Manual, 2016, about 14%
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 30 | |
| Load Calculations | 6 | |
| Code Requirements | 4 | |
| Controls | 10 | |
| Ducting, Insulation | 10 | |
| Piping | 6 | |
| Safety - OSHA | 4 | |
| Equipment | 10 |
Exam day details
- Administered by Prov, Inc. for the West Virginia Contractor Licensing Board.
- Fee: $59.95 to Prov per exam, whether first try or retake. Licensing board application and license fees are separate.
- 80 questions in 3 hours; 70% to pass.
- Pass the Contractor Licensing Act exam as well; every West Virginia contractor takes it.
- Open book: bring the references the bulletin lists (any older or newer edition of the same book is allowed, but the exam is scored on the edition shown in the bulletin). Prepare them only by highlighting and attaching permanent tabs; handwritten notes, moveable tabs and sticky notes are not allowed.
- Computer-based at a Prov testing center or at home with Examroom remote proctoring. Only a simple 4-function calculator is allowed.
- You get your score at the testing center. There is no waiting period between attempts and no limit on retakes; retake fees equal the first-try fee.
- Change or cancel at least 3 business days before your test date or you forfeit the fee. You can ask for a review of your exam after failing it at least twice with a score within 10 points of 70%.
Note: The Contractor Licensing Board bulletin lists the 2021 IMC for this exam, but the West Virginia State Building Code (87 CSR 4) adopts the 2018 edition. Our questions follow the 2021 IMC text and avoid sections that changed between editions where possible. Confirm the edition with the Board before you test.
Frequently asked questions
What's on the West Virginia HVAC contractor exam?
80 questions: general knowledge 30, controls 10, ducting and insulation 10, equipment 10, piping 6, load calculations 6, code requirements 4 and safety (OSHA) 4.
Which IMC edition is the exam based on?
The Board bulletin lists the 2021 IMC, even though the West Virginia State Building Code adopts the 2018 edition. The IMC is about 70% of the questions.
Free questions with answers
Show all 10 free questions and answers
Under 42 CSR 34 3.11, which of the following makes an HVAC system "non-residential" no matter how small its capacity?
Answer: The system consists of packaged rooftop units
Rule 3.11 (official 2023 text) lists four triggers: more than four separate units with a combined capacity of more than 20 tons (520,000 BTUs); use in commercial structures over 5,000 square feet; fire dampers used or required; and packaged rooftop units (3.11.4). Packaged rooftop units make a system non-residential regardless of size. A 4,500 square foot building is under the 5,000 square foot line, three three-ton units are under both the unit-count and tonnage limits, and a duplex is a dual family structure covered by the residential definition in Code 21-16-2(e).
Reference: 42 CSR 34 (West Virginia HVAC rule), 42 CSR 34 3.11.4
Which task is listed as "routine maintenance" in W. Va. Code 21-16-2(i), so that a person doing only that task is not required to hold an HVAC license?
Answer: Lubricating motor bearings on a rooftop air handler
Section 21-16-2(i) defines routine maintenance as scheduled work such as cleaning or replacing filters, greasing or lubricating motor bearings, adjusting or replacing belts, checking system and gas temperature, adjusting gas pressure and checking voltage and amperage draw. Section 21-16-3(d)(4) exempts routine maintenance from licensing. Replacing a coil or heat exchanger and altering ductwork are repair or alteration work.
Reference: West Virginia Code, W. Va. Code 21-16-2(i); 21-16-3(d)(4)
A 3,000 square foot office space is designed for the default occupant density in IMC Table 403.3.1.1 (5 people per 1,000 square feet; 5 cfm per person; 0.06 cfm per square foot). Using Equation 4-1, what is the breathing zone outdoor airflow Vbz?
Answer: 255 cfm
Population Pz = 5 x 3,000/1,000 = 15 people. Vbz = Rp x Pz + Ra x Az = 5 x 15 + 0.06 x 3,000 = 75 + 180 = 255 cfm. Using only the people term gives 75 cfm, only the area term gives 180 cfm, and doubling the area rate to 0.12 would give 435 cfm.
Reference: 2021 International Mechanical Code, IMC 403.3.1.1.1.1, Equation 4-1; Table 403.3.1.1
The manufacturer's installation instructions for a furnace allow a smaller clearance than the IMC does. According to IMC 304.2, which governs?
Answer: The IMC, because a conflict is resolved by the code
Section 304.2 says that where the code and the manufacturer's instructions or listing conflict, the code applies. The exception goes the other way: where a code provision is less restrictive than the listing or instructions, the listing and instructions control. Here the instructions are less restrictive, so the stricter IMC value controls.
Reference: 2021 International Mechanical Code, IMC 304.2
Which standard must duct smoke detectors installed in an air distribution system comply with under IMC 606.1?
Answer: UL 268A
Section 606.1 requires smoke detectors listed and labeled for installation in air distribution systems, and says duct smoke detectors shall comply with UL 268A. Other smoke detectors comply with UL 268. UL 181 covers ducts and connectors and UL 900 covers air filters.
Reference: 2021 International Mechanical Code, IMC 606.1
A low-water cutoff on a steam boiler is required by IMC 1007.1 to do what when the water level drops below the lowest safe level?
Answer: Automatically stop combustion operation of the appliance
Section 1007.1 requires steam and hot water boilers to have a low-water cutoff, and 1007.2 requires it to automatically stop combustion when the level drops below the lowest safe water level set by the manufacturer. Coil-type and water-tube boilers needing forced circulation may use a flow sensing control instead.
Reference: 2021 International Mechanical Code, IMC 1007.1 and 1007.2
Under IMC 603.3, ducts are classified by maximum operating pressure. What must be true of a duct's pressure classification?
Answer: It must equal or exceed the design pressure of the air system it serves
Section 603.3 classifies ducts at positive or negative 0.5, 1.0, 2.0, 3.0, 4.0, 6.0 or 10.0 inches of water column and requires the classification to equal or exceed the design pressure of the system in which the duct is used. There is no doubling rule.
Reference: 2021 International Mechanical Code, IMC 603.3
What minimum slope must a condensate drain from a cooling coil maintain in the direction of discharge, under IMC 307.2.1?
Answer: 1/8 unit vertical in 12 units horizontal
Section 307.2.1 requires condensate piping to hold a minimum horizontal slope of 1/8 unit vertical in 12 units horizontal (a 1-percent slope) in the direction of discharge. A steeper slope is allowed but 1/8 inch per foot is the minimum.
Reference: 2021 International Mechanical Code, IMC 307.2.1
A non-self-supporting ladder has a working length of 16 feet (foot to top support). Using the angle rule in 29 CFR 1926.1053(b)(5)(i), about how far from the wall should the foot of the ladder be placed?
Answer: 4 feet
Section 1926.1053(b)(5)(i) says non-self-supporting ladders must be used at an angle so that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length. 16 x 1/4 = 4 feet. Using one-half would give 8 feet and 3 feet is the rail extension rule.
Reference: 29 CFR 1926 (OSHA construction standards), 29 CFR 1926.1053(b)(5)(i)
A floor furnace has its lower 6 inches sealed by the manufacturer to prevent water entry. What is the minimum clearance of the lowest portion of the furnace from grade, per IMC 910.4?
Answer: 2 inches
Section 910.4 requires the lowest portion of a floor furnace to have at least 6 inches of clearance from grade, except that where the lower 6 inches are sealed by the manufacturer against water entry, the clearance may be reduced to not less than 2 inches. If the clearances are not present, a pit must be excavated.
Reference: 2021 International Mechanical Code, IMC 910.4
Sources
- Prov: West Virginia Contractor Licensing Board Candidate Information Bulletin (CIB 2026.05.07) (opens in a new tab)
- West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)
- Prov: register for West Virginia exams (opens in a new tab)
- West Virginia Code Chapter 30, Article 42 (Contractor Licensing Act) (opens in a new tab)
- 28 CSR 2: Contractor Licensing Board rule (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.