Requirements at a glance
| Agency | Virginia Department of Professional and Occupational Regulation (DPOR), Board for Contractors; exams by PSI |
|---|---|
| Experience | 4 years of water distribution experience plus 32 hours of school, or 7 years plus 16 hours (confirm in 18VAC50-30-39) |
| Exam | backflow exam: 40 items, 150 minutes, 30 correct |
| Books allowed | 2021 IPC (Virginia Plumbing Code), ASSE Series 5000-2009, Backflow Prevention Theory and Practice (2004) and the Manual of Cross-Connection Control, 10th Edition |
| Fees | $100 to PSI; DPOR license fee separate |
Technicians who test, maintain and repair backflow prevention assemblies and apply to the Virginia Board for Contractors for a backflow license.
Official links
How to get licensed, step by step
Check the education and experience rules
You must be 18 and document training and work experience. The requirements depend on the license level; see 18VAC50-30-39.
Virginia Administrative Code 18VAC50-30 (tradesman regulations) (opens in a new tab)Virginia DPOR: Tradesmen licensing (opens in a new tab)
Apply to the Board for Contractors
The Board reviews your application first and approves you to take the exam. Disclose any convictions.
Register and schedule the backflow exam with PSI
After approval, pay PSI and book a seat. Your eligibility is good for one year and you can retake within that year.
Schedule with PSI (Virginia DPOR exams) (opens in a new tab)
Get licensed
Send your passing result to the Board with the license fee ($150 for an original journeyman or master license; additional designations $105). Trade licenses run three years and need continuing education (3 hours per designation) on the current code edition.
Virginia DPOR: Tradesmen licensing (opens in a new tab)Virginia Administrative Code 18VAC50-30 (tradesman regulations) (opens in a new tab)
How to prepare
- Bring the editions on PSI's list: the 2020 NEC for electrical and the 2021 IPC, IMC and IFGC (Virginia Plumbing, Mechanical and Fuel Gas Codes) for plumbing, HVAC and gas. Virginia's 2024 code cycle (NEC 2023 and the 2024 I-codes) is tentatively set to take effect in October 2027; until PSI publishes a new bulletin, code questions use the 2021 USBC editions.
- Exam fees may change: a rule effective 3/11/2026 raised the Board's exam fee caps, though DPOR still lists $100 for journeyman and $125 for master exams. Confirm the fee with PSI when you register.
- Tab your books before exam day with permanent tabs. You can highlight, underline and index, but you can't write in them, use removable tabs or bring loose papers or study guides.
- Ten items on every journeyman and master exam (nine on the residential exams) come from the Board's rules, 18VAC50-30. They are easy points if you read the regulation once.
- Testing and troubleshooting is 16 of the 40 items. Know the test procedure and pass criteria for each assembly type.
- Tab the assembly descriptions and the maintenance and repair sections in the cross-connection manual.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Virginia Plumbing Code and 18VAC50-30. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 Virginia Plumbing Code (2021 IPC with Virginia amendments)Essential
Allowed in the exam room. The whole plumbing exam is based on this edition.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
ASSE/IAPMO/ANSI Series 5000-2009: Cross-Connection Control Professional Qualifications Standard
Allowed in the backflow exam room.
Backflow Prevention Theory and Practice, 2004 (USC Foundation for Cross-Connection Control and Hydraulic Research and CTREEO)
Allowed in the backflow exam room. Assembly principles, testing and troubleshooting.
USC Foundation for Cross-Connection Control (opens in a new tab)
Manual of Cross-Connection Control, 10th Edition (USC Foundation for Cross-Connection Control and Hydraulic Research)
Allowed in the backflow exam room. Hazards, assemblies and installation.
USC Foundation for Cross-Connection Control (opens in a new tab)
Board for Contractors Individual License and Certification Regulations (18VAC50-30)Essential
Free online. Ten items on every journeyman and master exam come from this regulation.
Virginia Administrative Code 18VAC50-30 (tradesman regulations) (opens in a new tab)
Official reference list (as published by the testing agency)
- International Plumbing Code (IPC), 2021, with Virginia amendments (Virginia Plumbing Code)
- ASSE/IAPMO/ANSI Series 5000-2009, Cross-Connection Control Professional Qualifications Standard
- Backflow Prevention Theory and Practice, 2004 (USC Foundation for Cross-Connection Control and Hydraulic Research and CTREEO)
- Manual of Cross-Connection Control, 10th Edition (USC Foundation for Cross-Connection Control and Hydraulic Research)
- Board for Contractors Individual License and Certification Regulations (18VAC50-30)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Standards of Practice | 3 | |
| Standards of Conduct | 2 | |
| Renewal and Reinstatement | 2 | |
| Definitions | 1 | |
| Qualification for Licensure | 1 | |
| Revocation | 1 | |
| Testing/Troubleshooting | 16 | |
| Assemblies/Devices | 4 | |
| General Subject Knowledge | 6 | |
| Maintenance and Repair | 2 | |
| Laws and Rules | 1 | |
| Safety | 1 |
Exam day details
- Administered by PSI Services for the Virginia Department of Professional and Occupational Regulation (DPOR), Board for Contractors.
- Fee: $100 to PSI per exam, not refundable or transferable and valid for one year. DPOR application and license fees are separate.
- 40 items in 150 minutes; 30 correct (75%) to pass.
- Eligibility: 4 years of water distribution experience plus 32 hours of school, or 7 years plus 16 hours (18VAC50-30-39; confirm the current rule).
- Testing and troubleshooting is 16 of the 40 items: know the test procedures and pass criteria for RP, DC and PVB assemblies.
- Open book: bring your own bound copies of the listed references. You may highlight, underline and index them beforehand and add permanent tabs, but removable tabs, loose papers, writing and study guides are not allowed.
- PSI may add unscored experimental questions to the exam.
- Exam fees may change: a rule effective 3/11/2026 raised the Board's exam fee caps, though DPOR still lists $100 (journeyman) and $125 (master). Confirm the fee with PSI when you register.
- The Board for Contractors must approve your application first (education and experience); then you pay and register with PSI. Your exam eligibility is good for one year and you can retake within that year.
- Every Virginia tradesman exam includes 10 items on the Board's rules (18VAC50-30): standards of practice, standards of conduct, renewal and reinstatement, definitions, qualification for licensure and revocation.
Note: These facts come from the PSI bulletin dated 1/14/2025; no newer bulletin was found. The 2021 Virginia USBC (NEC 2020 and the 2021 I-codes) is in force now. Virginia's 2024 code cycle (NEC 2023 and the 2024 I-codes) is tentatively scheduled to take effect in October 2027, and PSI will likely update its bulletin then; that date is not confirmed. Check the current PSI bulletin before you test. ASSE/IAPMO/ANSI Series 5000-2009, Backflow Prevention Theory and Practice (2004) and the Manual of Cross-Connection Control (10th ed.) are not freely readable, so field-test questions follow the free EPA Cross-Connection Control Manual and the IPC 2021 and were not checked against those books. Virginia requires testing to the ASSE 5000-series procedures, so where your course's steps or pass values differ from the EPA manual, follow the course.
Frequently asked questions
How many questions are on the Virginia backflow exam?
40 items in 150 minutes, and you need 30 correct. Ten items cover the Board's rules (18VAC50-30).
Which books can I bring?
The 2021 IPC, ASSE Series 5000-2009, Backflow Prevention Theory and Practice (2004) and the Manual of Cross-Connection Control, 10th Edition.
What is the biggest topic?
Testing and troubleshooting, with 16 items.
Free questions with answers
Show all 10 free questions and answers
A tester closes the number 2 shut-off valve on a reduced pressure principle assembly and, before hooking up the test kit, sees water running steadily from the relief valve. What does the EPA manual say this probably means and what should the tester do?
Answer: The first check valve is probably fouled, so testing should wait until the assembly is serviced
The manual says to wait several moments after closing the number 2 shut-off before hooking up the hoses on a reduced pressure device. Water leaving the relief valve in that period in all likelihood means the first check is fouled, and it is impractical to test until the valve is serviced. The waiting period is not needed for double check assemblies, which have no relief valve.
Reference: EPA Cross-Connection Control Manual (EPA 816-R-03-002, 2003), Chapter 5, Testing Procedures for Backflow Preventers: general steps before testing, item 6
Which two conditions must both exist before backflow can occur, according to the EPA manual?
Answer: A link between the two systems and a resultant force acting toward the potable supply
The manual states that two factors are essential for backflow: there must be a link between the two systems, and the resultant force must be toward the potable supply. Removing either one, by eliminating the connection or by a device that prevents reversed flow, stops the contamination. Valve leakage or meter location is not part of the basic theory.
Reference: EPA Cross-Connection Control Manual (EPA 816-R-03-002, 2003), Chapter 3, Theory of Backflow and Backsiphonage
A tester sees a reduced pressure principle assembly on a chemical feed line. Which hazard rating and conditions does Table 608.1 list for it?
Answer: High or low hazard, backpressure or backsiphonage
The reduced pressure principle backflow prevention assembly (ASSE 1013, AWWA C511, CSA B64.4) is the assembly listed for high or low hazard under backpressure or backsiphonage, sizes 3/8 to 16 inch. That is why it is the assembly the EPA manual calls the backbone of cross-connection control programs.
Reference: 2021 International Plumbing Code (Virginia Plumbing Code), Table 608.1
A certified tester repairs the first check of a reduced pressure principle assembly. Under IPC Section 312.10.2, when must the assembly be tested again?
Answer: Immediately after the repair
Section 312.10.2 requires testing at the time of installation, immediately after repairs or relocation, and at least annually. A repaired assembly is therefore retested at once, not left until the next annual date. Waiting for the purveyor or a 90-day window does not meet the code.
Reference: 2021 International Plumbing Code (Virginia Plumbing Code), Section 312.10.2
A certified backflow prevention device worker moves to a new house. Under 18VAC50-30-160, what must the worker do?
Answer: Report the change of address to the Board in writing within 30 days
Section 160 requires any change of address to be reported to the Board in writing within 30 days. The Board is not responsible if the regulant fails to receive notices because the address was not updated, and a post office box alone is not acceptable.
Reference: Board for Contractors Individual License and Certification Regulations (18VAC50-30), 18VAC50-30-160
Under 18VAC50-30-190, what is evidence of abandonment?
Answer: Unjustified cessation of work under the contract for 30 days or more
The prohibited acts list says unjustified cessation of work under the contract for a period of 30 days or more shall be considered evidence of abandonment. A shorter delay does not create that presumption on its own.
Reference: Board for Contractors Individual License and Certification Regulations (18VAC50-30), 18VAC50-30-190, item 6
How long is a backflow prevention device worker certification valid before it must be renewed, under 18VAC50-30-120?
Answer: Two years from the last day of the month in which it was issued
Three-year terms apply to tradesman, gas fitter, LP gas fitter and natural gas fitter provider licenses. All other licenses and certifications, including the backflow certification, expire two years from the last day of the month in which they were issued.
Reference: Board for Contractors Individual License and Certification Regulations (18VAC50-30), 18VAC50-30-120 A and B
An applicant for the backflow exam has seven years of water distribution experience. How many hours of Board-approved formal vocational training does 18VAC50-30-42 require?
Answer: 16 hours
Applicants with seven or more years of experience qualify with 16 hours of formal vocational training in a board-approved school. Those with four years need 32 hours.
Reference: Board for Contractors Individual License and Certification Regulations (18VAC50-30), 18VAC50-30-42 A.2
A certified backflow worker is disciplined by a county for backflow work. Under 18VAC50-30-190, what happens before the Board takes disciplinary action of its own?
Answer: The Board reviews the county's action first
Item 12 lists as a prohibited act having been disciplined by any county, city, town, state or federal governing body for actions relating to the practice of backflow prevention device work, and says that action shall be reviewed by the board before the board takes any disciplinary action of its own.
Reference: Board for Contractors Individual License and Certification Regulations (18VAC50-30), 18VAC50-30-190, item 12
Under Va. Code 54.1-1128, which work does a backflow prevention device worker perform?
Answer: Maintenance, repair, testing or periodic inspection of cross connection control devices
The statute defines a backflow prevention device worker as an individual who engages in or offers to engage in the maintenance, repair, testing or periodic inspection of cross connection control devices, including reduced pressure principle devices, double check valve assemblies, double detector check assemblies and pressure type vacuum breaker assemblies.
Reference: Code of Virginia, Title 54.1, Chapter 11, Section 54.1-1128
Sources
- PSI: Virginia Individual License and Certification Candidate Information Bulletin (1/14/2025) (opens in a new tab)
- Virginia DPOR: Tradesmen licensing (opens in a new tab)
- Virginia Administrative Code 18VAC50-30 (tradesman regulations) (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.