Vermont licensing exam

Vermont Journeyman Plumber Exam: Practice Test & Licensing Guide

The Prov exam for a Vermont journeyman plumber license: 80 open-book questions in 3 hours on drainage, venting, water supply, plan reading and safety under the 2024 IPC and the Vermont Plumbing Rules. 70% to pass.

Questions
80
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Sanitary Drainage & Indirect/Special Waste

A 4-inch soil stack finishes at the bottom in a horizontal drain. Under Section 704.3, how far downstream of the stack base must a horizontal branch connect, measured as a minimum?

Requirements at a glance

AgencyVermont Division of Fire Safety (Plumbers' Examining Board); exam by Prov
Exam80 questions, 3 hours, open book, 70% to pass
ExperienceApprenticeship verified by the Apprenticeship Council or equivalent experience
Books allowed2025 Vermont Plumbing Rules; 2024 IPC; Basic Safety (NCCER, 2015)
Fees$80 to Prov; Division application and license fees are separate

Plumbers applying to the Vermont Division of Fire Safety (Plumbers' Examining Board) for a journeyman license. Vermont asks for an apprenticeship verified by the Apprenticeship Council or equivalent experience, then a passing exam score.

How to get licensed, step by step

  1. Meet the experience requirement

    Complete an apprenticeship verified by the Apprenticeship Council or equivalent experience the Board accepts. Check the Division's page for the current requirement.

    Vermont Division of Fire Safety: plumbing licensing (opens in a new tab)26 V.S.A. chapter 39 (plumbers) (opens in a new tab)

  2. Apply to the Division of Fire Safety

    Send the application and fee to Trade Licensing in Waterbury (802-479-7564). The Division confirms your eligibility and, once the Board approves you, sends your details to Prov. Check its page for current forms and fees.

    Vermont Division of Fire Safety: plumbing licensing (opens in a new tab)

  3. Schedule with Prov

    Once the Board approves you, it sends your details to Prov. Schedule at provexam.com/scheduler (sign in with your email and last name) or by phone at 801-733-4455. Prov lists one Vermont test center, in Lyndonville; you can also test at any Prov center in the U.S. or remotely from home through Examroom.ai. You get your score as soon as you finish.

    Schedule with Prov (opens in a new tab)Prov: Vermont Fire Safety Candidate Information Bulletin (PDF) (opens in a new tab)

  4. Get licensed

    Prov reports your result to the Division, which issues the license. Licenses run 2 years. The license fee is $90 for a journeyman, $120 for a master and $50 per specialty field (26 V.S.A. 2193), and renewal needs 8 hours of Board-approved instruction in the preceding 24 months (26 V.S.A. 2195).

    Vermont Division of Fire Safety: plumbing licensing (opens in a new tab)26 V.S.A. chapter 39 (plumbers) (opens in a new tab)

  5. Complete the Vermont energy goals module

    Vermont requires a Vermont Energy Goals education module (no more than 2 hours by law; the Division says it takes about 20 minutes) before an initial license and each renewal. Send the completion certificate with your application.

    Vermont Division of Fire Safety: trade licensing (opens in a new tab)

How to prepare

  • Sanitary drainage (15) and vents (14) are 29 of 80 questions; tab IPC Chapters 3, 5, 6 and 9.
  • Plan reading and isometrics is 10 questions, and 8 more are general knowledge and plumbing math.
  • The 2025 Vermont Plumbing Rules adopt the 2024 IPC with Vermont amendments, including gas piping and sprinklers moving to the Fire and Building Safety Code. The Division's web page still mentions the 2021 IPC; the rules and the Prov bulletin name 2024.
  • You can take the exam up to 3 times on one approval (good for 3 years), with no waiting period and the same $80 fee each time; after that you reapply.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2024 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • 2025 Vermont Plumbing Rules (open book)
  • International Plumbing Code, 2024 (open book)
  • Basic Safety, 2015, NCCER (open book)

What's on the exam

Official content outline from Prov, Inc. (number of questions per topic):

TopicQuestions
General Knowledge & Plumbing Math8
Fixtures & Fittings5
Water Heaters5
Water Supply and Distribution8
Sanitary Drainage & Indirect/Special Waste15
Vents & Vent Systems14
Traps, Interceptors & Separators5
Storm & Roof Drainage5
Plan Reading & Isometrics10
Safety5

Exam day details

  • Administered by Prov, Inc. for the Vermont Department of Public Safety, Division of Fire Safety.
  • Fee: $80 to Prov per exam. Division application and license fees are separate.
  • 80 questions in 3 hours; 70% to pass.
  • Open book: only the references marked open book below are permitted in the exam room. Pen highlighting and underlining and permanent tabs are allowed; Post-it notes, loose formula sheets and marking your books during the exam are not.
  • Once the Board approves you, it sends your details to Prov; schedule at provexam.com/scheduler or by phone at 801-733-4455. Prov lists one Vermont test center (Lyndonville), any Prov center in the U.S., or remote testing from home through Examroom.ai.
  • You can take the exam up to 3 times on one approval, with no waiting period between attempts; after that you reapply to the Division. The approval is good for 3 years. Each attempt costs the $80 exam fee.

Note: The 2025 Vermont Plumbing Rules and the Prov bulletin both name the 2024 IPC. The Division's plumbing web page still mentions the 2021 IPC, so check the current bulletin before your test date.

Frequently asked questions

What's on the Vermont journeyman plumber exam?

80 questions: sanitary drainage and indirect/special waste 15, vents and vent systems 14, plan reading and isometrics 10, general knowledge and plumbing math 8, water supply and distribution 8, fixtures and fittings 5, water heaters 5, traps, interceptors and separators 5, storm and roof drainage 5, and safety 5.

Which IPC edition is on the exam?

The 2024 IPC, with the Vermont amendments in the 2025 Vermont Plumbing Rules (effective November 4, 2025). Vermont's rules move gas piping and sprinklers to the Fire and Building Safety Code.

Is the exam open book?

Yes, with the three approved references only. Test-prep guides are not allowed in the exam room.

Free questions with answers

Show all 10 free questions and answers
  1. A 4-inch soil stack finishes at the bottom in a horizontal drain. Under Section 704.3, how far downstream of the stack base must a horizontal branch connect, measured as a minimum?

    Answer: 40 inches, or 10 pipe diameters

    Section 704.3 puts horizontal branches at least 10 times the stack diameter downstream of the stack base or offset. For a 4-inch stack that is 10 x 4 = 40 inches. The other figures are 5, 7.5 and 15 diameters, which do not match the section.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 704.3

  2. The vent system must protect fixture trap seals so they are not exposed to a pressure difference greater than what amount?

    Answer: 1 inch of water column

    Section 901.2 requires a vent system that admits or releases air so that no trap seal sees a pressure differential of more than 1 inch of water column. The larger figures would let seals be siphoned or blown out.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 901.2

  3. What is the minimum distance from the centerline of a water closet to a side wall or partition under Section 405.3.1?

    Answer: 15 inches

    Section 405.3.1 requires a water closet, urinal, lavatory or bidet to be set at least 15 inches from its center to any side wall, partition, vanity or other obstruction. The 21-inch figure is the required clear space in front of the fixture, not the side clearance.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 405.3.1

  4. Under Vermont's Section 501.1.1, what must tank-style and tankless water heaters be equipped with?

    Answer: An ASSE 1017 temperature-actuated mixing valve

    Vermont's Section 501.1.1 requires an ASSE 1017 (or 1017/1070 where applicable) temperature-actuated mixing valve on all tank-style and tankless water heaters, installed at the hot water source per Section 613.1. Water to fixtures is limited to 120°F.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 501.1.1

  5. Vermont amends Table 604.4. What is the maximum flow rate for a private lavatory faucet and for a sink faucet?

    Answer: 1.5 gpm at 60 psi for the lavatory and 1.8 gpm at 60 psi for the sink

    Table 604.4 as published in the Vermont rules lists private lavatory faucets at 1.5 gpm at 60 psi and sink faucets at 1.8 gpm at 60 psi. Showerheads are 2.0 gpm at 80 psi.

    Reference: 2024 International Plumbing Code (Vermont amended), Table 604.4

  6. How many gallons does 100 feet of 4-inch pipe hold? Use 231 cubic inches per gallon and pi x r squared for the area.

    Answer: About 65 gallons

    Area of a 4-inch circle = 3.1416 x 2 x 2 = 12.57 sq in. Volume per foot = 12.57 x 12 = 150.8 cu in = 0.653 gal. For 100 ft: 0.653 x 100 = 65.3 gallons. Using the diameter as the radius gives about 261.

    Reference: 2024 International Plumbing Code (Vermont amended), Plumbing math, pipe volume

  7. Where Vermont allows a building trap because local conditions require it, what size must the fresh air vent on the inlet side be for a 4-inch house drain?

    Answer: 2 inches, which is half the diameter of the drain

    Vermont's Section 1002.6 requires the fresh air vent or intake to be at least half the diameter of the drain it connects to, so 4 / 2 = 2 inches. It must be carried above grade and end in a screened outlet outside the building at or near the sill, with cleanouts on both sides of the trap.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 1002.6

  8. A leader is connected to a combined sewer carrying both sanitary and storm flow. What does Section 1103.1 require?

    Answer: The leader or storm drain must be trapped

    Section 1103.1 requires leaders and storm drains connected to a combined sewer to be trapped, either individually on each conductor branch or by a single main trap before the connection. Leaders to a separate building storm sewer need no trap.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 1103.1

  9. A 4-inch horizontal drain runs 40 feet on the plan at the minimum Table 704.1 slope. What is the total fall?

    Answer: 5 inches

    A 4-inch drain needs 1/8 inch per foot (Table 704.1). Fall = 40 ft x 1/8 in = 5 inches. Using 1/4 inch per foot gives 10 inches.

    Reference: 2024 International Plumbing Code (Vermont amended), Table 704.1

  10. At what height above a lower level must fall protection be provided for workers on an unprotected edge in construction?

    Answer: Six feet

    29 CFR 1926.501(b)(1) requires fall protection for employees on a walking or working surface with an unprotected side or edge 6 feet or more above a lower level in construction.

    Reference: OSHA 29 CFR 1926 Subpart M, 29 CFR 1926.501(b)(1)

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.