Vermont licensing exam

Vermont P1/P2 Water Heater and Heating System Specialist Exam: Practice Test & Licensing Guide

The Prov exam for Vermont's combined P1/P2 water heater and heating system specialist: 60 open-book questions in 3 hours on hydronic systems, piping, low-pressure steam boilers and water. 70% to pass.

Questions
60
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge

Which work falls under the P1 Water Heater Specialist field in the Vermont Plumbing Rules?

Requirements at a glance

AgencyVermont Division of Fire Safety (Plumbers' Examining Board); exam by Prov
Exam60 questions, 3 hours, open book, 70% to pass (combined P1/P2)
ExperienceSpecialist training and experience set by the Division; check the plumbing application for the hours required
Books allowed2025 Vermont Plumbing Rules; 2024 IPC; HVAC Level 1 and 2 (2013); Low Pressure Boilers 5th ed.; Modern Refrigeration and Air Conditioning 21st ed.
Fees$80 to Prov; Division application and license fees are separate

Installers of residential, industrial or commercial water heaters, hot water supply tanks and hydronic space heating systems (including radiant and solar hydronic design), applying to the Vermont Division of Fire Safety (Plumbers' Examining Board) for a specialist license. Work on steam systems is limited to operating pressures not above 15 PSIG. Prov also lists separate P1-only (30 questions), P2-only and P3 water treatment exams; this page covers the combined P1/P2 exam.

How to get licensed, step by step

  1. Meet the experience requirement

    Specialist licenses need training and experience the Division sets; the plumbing application lists the hours. Ask the Division whether you need P1, P2 or the combined P1/P2 before you register.

    Vermont Division of Fire Safety: plumbing licensing (opens in a new tab)26 V.S.A. chapter 39 (plumbers) (opens in a new tab)

  2. Apply to the Division of Fire Safety

    Send the application and fee to Trade Licensing in Waterbury (802-479-7564). The Division confirms your eligibility and, once the Board approves you, sends your details to Prov. Check its page for current forms and fees.

    Vermont Division of Fire Safety: plumbing licensing (opens in a new tab)

  3. Schedule with Prov

    Once the Board approves you, it sends your details to Prov. Schedule at provexam.com/scheduler (sign in with your email and last name) or by phone at 801-733-4455. Prov lists one Vermont test center, in Lyndonville; you can also test at any Prov center in the U.S. or remotely from home through Examroom.ai. You get your score as soon as you finish.

    Schedule with Prov (opens in a new tab)Prov: Vermont Fire Safety Candidate Information Bulletin (PDF) (opens in a new tab)

  4. Get licensed

    Prov reports your result to the Division, which issues the license. Licenses run 2 years. The license fee is $90 for a journeyman, $120 for a master and $50 per specialty field (26 V.S.A. 2193), and renewal needs 8 hours of Board-approved instruction in the preceding 24 months (26 V.S.A. 2195).

    Vermont Division of Fire Safety: plumbing licensing (opens in a new tab)26 V.S.A. chapter 39 (plumbers) (opens in a new tab)

  5. Complete the Vermont energy goals module

    Vermont requires a Vermont Energy Goals education module (no more than 2 hours by law; the Division says it takes about 20 minutes) before an initial license and each renewal. Send the completion certificate with your application.

    Vermont Division of Fire Safety: trade licensing (opens in a new tab)

How to prepare

  • Piping, pumps and valves (12), general knowledge (10) and low pressure steam boilers (10) are over half the exam.
  • Steam work under this license is limited to systems not above 15 PSIG.
  • The 2025 Vermont Plumbing Rules adopt the 2024 IPC with Vermont amendments, including gas piping and sprinklers moving to the Fire and Building Safety Code. The Division's web page still mentions the 2021 IPC; the rules and the Prov bulletin name 2024.
  • You can take the exam up to 3 times on one approval (good for 3 years), with no waiting period and the same $80 fee each time; after that you reapply.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2024 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • 2025 Vermont Plumbing Rules (open book)
  • International Plumbing Code, 2024 (open book)
  • HVAC Level 1, 2013 (open book)
  • HVAC Level 2, 2013 (open book)
  • Low Pressure Boilers, 5th edition, American Technical Publishers (open book)
  • Modern Refrigeration and Air Conditioning, 21st edition, Goodheart-Wilcox (open book)

What's on the exam

Official content outline from Prov, Inc. (number of questions per topic):

TopicQuestions
General Knowledge10
Hydronic Systems9
Piping, Pumps, Valves12
Fuel Gas and Oil4
Low Pressure Steam Boilers10
Water7
Testing and Inspection4
Local Amendments4

Exam day details

  • Administered by Prov, Inc. for the Vermont Department of Public Safety, Division of Fire Safety.
  • Fee: $80 to Prov per exam. Division application and license fees are separate.
  • 60 questions in 3 hours; 70% to pass.
  • Open book: only the references marked open book below are permitted in the exam room. Pen highlighting and underlining and permanent tabs are allowed; Post-it notes, loose formula sheets and marking your books during the exam are not.
  • Once the Board approves you, it sends your details to Prov; schedule at provexam.com/scheduler or by phone at 801-733-4455. Prov lists one Vermont test center (Lyndonville), any Prov center in the U.S., or remote testing from home through Examroom.ai.
  • You can take the exam up to 3 times on one approval, with no waiting period between attempts; after that you reapply to the Division. The approval is good for 3 years. Each attempt costs the $80 exam fee.

Note: The 2025 Vermont Plumbing Rules and the Prov bulletin both name the 2024 IPC. The Division's plumbing web page still mentions the 2021 IPC, so check the current bulletin before your test date.

Frequently asked questions

What's on the Vermont P1/P2 exam?

60 questions: piping, pumps and valves 12, general knowledge 10, low pressure steam boilers 10, hydronic systems 9, water 7, and fuel gas and oil, testing and inspection, and local amendments 4 each.

Should I take the combined exam or P1 or P2 alone?

Prov lists P1 (water heaters), P2 (heating systems) and the combined P1/P2 as separate exams. Ask the Division of Fire Safety which one your license needs before you register; exam fees are not refunded if you take the wrong exam.

Which references are allowed?

The 2025 Vermont Plumbing Rules, the 2024 IPC, HVAC Level 1 and 2 (2013), Low Pressure Boilers 5th edition and Modern Refrigeration and Air Conditioning 21st edition.

Free questions with answers

Show all 10 free questions and answers
  1. Which work falls under the P1 Water Heater Specialist field in the Vermont Plumbing Rules?

    Answer: Installation, replacement and repair of residential, industrial or commercial domestic water heaters or hot water supply tanks

    Section 8(C) lists P1 as domestic water heaters and hot water supply tanks. Hydronic space heating is the P2 field, and water treatment, well pressure tanks and pumps belong to P3. Drainage work is general plumbing, not a specialist field.

    Reference: 2025 Vermont Plumbing Rules, Section 8(C)

  2. A specialist license covering steam systems is limited to systems operating at what maximum pressure?

    Answer: 15 psi

    The P2 Heating System Specialist field says any work on steam systems is limited to operating pressure not to exceed 15 PSI. Higher pressures fall outside the specialist license and need a plumber license.

    Reference: 2025 Vermont Plumbing Rules, Section 8(C)

  3. A boiler is filled through a potable water connection, and propylene glycol antifreeze will be added to the loop. Which protection does Section 608.17.2 require at the fill connection?

    Answer: An air gap or a reduced pressure principle backflow preventer complying with ASSE 1013, AWWA C511 or CSA B64.4

    Section 608.17.2 normally calls for an intermediate atmospheric vent device (ASSE 1012, 1081, CSA B64.3) at a boiler's potable supply. When conditioning chemicals or antifreeze are introduced, the connection must instead be protected by an air gap or reduced pressure principle assembly.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 608.17.2

  4. A boiler's makeup water line serves mechanical equipment. Which valve rule applies to the water supply pipe to each appliance or mechanical equipment?

    Answer: A shutoff valve is required on the supply pipe to each appliance or mechanical equipment

    Section 606.2 requires shutoff valves on the fixture supply to plumbing fixtures, on the supply to each sill cock and on the water supply pipe to each appliance or mechanical equipment, so each can be isolated for service.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 606.2

  5. A shutoff valve for a boiler fill line is installed in a basement ceiling, away from the boiler it serves. What does Section 606.4 require?

    Answer: The valve must be identified to show which fixture or appliance it serves

    Section 606.4 requires service and hose bibb valves to be identified, and other valves that are not adjacent to the fixture or appliance to be identified to show what they serve. The code does not require a color or a relocation.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 606.4

  6. Why is a pigtail (siphon loop) installed between a steam boiler and its pressure gauge?

    Answer: Water collects in the loop, protecting the gauge from live steam and high temperature

    A pigtail holds condensate in its coil, so only water reaches the gauge's Bourdon tube instead of live steam, which would damage it. The gauge still reads steam pressure through the water seal.

    Reference: National Board NB-132, Model Boiler and Pressure Vessel Rules (Rev. 8), Part III, Section 2 (Heating Boilers): pressure gage syphon

  7. What shutdown means does Section 504.3 require for a gas-fired hot water supply system?

    Answer: A separate valve to shut off the energy fuel supply to the system

    Section 504.3 requires a disconnecting means for electric hot water supply systems per NFPA 70, and a separate valve to shut off the fuel supply for all other types. A thermostat or relief valve is not a shutdown means.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 504.3

  8. What does Vermont's Section 501.6 say about the outlet temperature of a tankless water heater for domestic use?

    Answer: A maximum of 120 degrees F after the ASSE 1017 mixing valve, without superseding the protective shower valve rules

    Section 501.6 limits tankless water to 120 degrees F maximum after the ASSE 1017 mixing valve when intended for domestic use, and says this does not supersede the protective shower valve requirement of Section 412.3.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 501.6

  9. A completed copper water supply system is to be tested with air instead of water. What does Section 312.6 require?

    Answer: At least 50 psi held for not less than 15 minutes

    Section 312.6 requires the water supply system to hold the system working pressure with water, or, for piping other than plastic, an air test of not less than 50 psi, held at least 15 minutes. Test water must come from a potable source. The 5 psi figure is the drainage and vent air test of Section 312.3.

    Reference: 2024 International Plumbing Code (Vermont amended), Section 312.6

  10. A priority-building job installs 1 boiler, 2 hydronic fan coils, 1 domestic hot water coil and 1 thermostatic mixing valve. Using $15 per item under Section 15(A)(1)(ii), what is the fee?

    Answer: $75

    All five items are listed at $15 each: 5 x $15 = $75, which is above the $50 minimum. $60 omits one item, $50 applies the minimum without counting, and $90 counts the two fan coils twice.

    Reference: 2025 Vermont Plumbing Rules, Section 15(A)(1)(ii)

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.