Texas licensing exam

Texas Tradesman Plumber-Limited Exam: Practice Test & Licensing Guide

TSBPE's entry-level plumbing license exam for one- and two-family dwellings: 85 closed-book questions on the 2018 IRC plumbing chapters and Texas plumbing law, plus a hands-on practical.

Questions
85
Time limit
2 hours
Passing score
70%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Water Heaters

Under the IRC, the T&P relief valve discharge pipe on water heater #2 ends 10 inches above the garage floor. What does the code require for the termination height?

Requirements at a glance

ScopePlumbing in one- and two-family dwellings, under a responsible master plumber
Experience4,000 hours as a registered plumber's apprentice under a responsible master plumber
Training24 hours: 6-hour apprentice course + OSHA 10 + 8 hours of residential code (or an approved apprenticeship)
ExamsWritten: 85 questions, 120 min, closed book, 70%. Practical: 6 tasks, 240 min.
Fees$36 TSBPE application + $68.50 Pearson VUE written exam; $35 license

Registered plumber's apprentices with 4,000 hours under a responsible master plumber and 24 hours of required training. The license covers one- and two-family dwellings only.

How to get licensed, step by step

  1. Register as a plumber's apprentice

    Register with TSBPE (fingerprints required). Hours you work before registering don't count.

    TSBPE: Plumber's Apprentice registration (opens in a new tab)

  2. Log 4,000 hours and finish the training

    Work under a responsible master plumber and complete the 24 hours of required training.

    TSBPE: required exam training (opens in a new tab)

  3. Apply to TSBPE

    Submit the Tradesman exam application with your employer certification forms and the $36 fee.

    TSBPE: Tradesman Plumber-Limited license (opens in a new tab)

  4. Pass the written exam at Pearson VUE

    85 questions in 120 minutes, closed book. You get up to 5 attempts within a year, with waiting periods after each failure.

    Schedule with Pearson VUE (TSBPE) (opens in a new tab)Pearson VUE TSBPE candidate handbook (opens in a new tab)

  5. Pass the practical

    At TSBPE's Austin or Waco center within a year of the written: joints in four materials, water heater violations, and a two-story drainage and vent layout in a scale model. Then pay the $35 license fee.

How to prepare

  • The written exam is closed book, so memorize the common values: drain slopes, trap seal depths, vent heights, relief valve settings and test pressures.
  • Water heaters are the single biggest topic, and both the written and practical exams test spotting violations. Learn relief valve discharge rules, drain pans, seismic straps, garage ignition height and shutoff valves.
  • Study the 2018 IRC plumbing and fuel gas chapters, plus the specific sections of the Texas Plumbing License Law and Board Rules listed in TSBPE's review course.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • 2018 International Residential Code (IRC), plumbing and fuel gas chaptersEssential

    The study code TSBPE names for the Tradesman exam. The exam is closed book, so use it to learn the values, not to bring along.

    Read free (opens in a new tab)

  • Texas Plumbing License Law and TSBPE Board Rules

    The review course lists the exact sections that are tested.

    Read the law free (opens in a new tab)

Official reference list (as published by the testing agency)
  • 2018 International Residential Code (IRC), plumbing and fuel gas chapters
  • Texas Plumbing License Law (Occupations Code Chapter 1301) and TSBPE Board Rules (22 TAC Part 17), sections listed in the TSBPE review course
  • Manufacturers' installation instructions for PVC, copper, threaded steel and no-hub cast iron joints

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Definitions7
General Requirements10
Fixtures and Fixture Fittings8
Water Heaters13
Water Supply and Distribution12
Sanitary Drainage10
Vents9
Traps5
Fuel Gas Piping5
Plumbing License Law and Board Rules6

Exam day details

  • Administered by Pearson VUE for the Texas State Board of Plumbing Examiners (TSBPE).
  • Fee: $68.50 written exam (Pearson VUE) + $36 TSBPE exam application fee; $35 license fee after you pass.
  • Written exam: 85 multiple-choice questions in 120 minutes, closed book, at a Pearson VUE test center. 70% to pass.
  • Practical exam (TSBPE, Austin or Waco): cutting and joining PVC, soldered copper, threaded steel and no-hub cast iron; spotting code violations on numbered water heater installations; designing and building a two-story drainage and vent system in a scale model. You have one year after the written exam to pass the practical.
  • Questions cover one- and two-family dwellings only. TSBPE's review course names the 2018 IRC as the study code.
  • Up to 5 written attempts within a year of authorization, with waits of 30, 60 and then 90 days after each failure.
  • TSBPE doesn't publish question counts per topic; the weights shown are our estimate from its review course and required training hours.

Note: TSBPE doesn't publish how many questions come from each topic, so our topic weights are estimates based on its review course and required training hours.

Frequently asked questions

Is the Texas Tradesman plumbing exam open book?

No. The written exam is closed book at a Pearson VUE test center: no code books, notes or scratch paper of your own. That's why practicing recall matters more than for open-book trade exams.

What code is the Texas Tradesman Plumber-Limited exam based on?

TSBPE's review course names the 2018 International Residential Code, since the Tradesman license covers one- and two-family dwellings only. A few questions come from the Texas Plumbing License Law and Board Rules.

What's on the Tradesman practical?

Hands-on joints (PVC, soldered copper, threaded steel and no-hub cast iron), finding code violations on numbered water heater installations, and designing and building a small two-story drainage and vent system in a scale model.

Free questions with answers

Show all 10 free questions and answers
  1. Under the IRC, the T&P relief valve discharge pipe on water heater #2 ends 10 inches above the garage floor. What does the code require for the termination height?

    Answer: Not more than 6 inches above the floor and not less than two pipe diameters

    Under the IRC, Section P2804.6.1 requires the relief valve discharge pipe to terminate not more than 6 inches and not less than two times the discharge pipe diameter above the floor or waste receptor flood-level rim. A pipe ending 10 inches above the floor is a violation. The 6-to-24-inch range is the rule for a water heater pan drain that ends outdoors (P2801.6.2), not for the relief valve discharge.

    Reference: 2018 International Residential Code, Section P2804.6.1

  2. A 40,000 Btu/h gas water heater gets all of its combustion air from indoors using the IRC standard method. What is the minimum required volume of the space?

    Answer: 2,000 cubic feet

    Under the IRC, Section G2407.5.1 requires a minimum of 50 cubic feet per 1,000 Btu/h of appliance input. 40,000 / 1,000 = 40, and 40 x 50 = 2,000 cubic feet. 800 comes from using 20 cubic feet per 1,000 Btu/h. 4,000 comes from using 100 cubic feet per 1,000 Btu/h. 1,000 comes from dividing by 2,000 instead of 1,000. Adjoining rooms that open to the space without doors count toward the volume (G2407.5).

    Reference: 2018 International Residential Code, Section G2407.5.1

  3. A PEX water line runs through a bored hole in a stud. The edge of the hole is 3/4 inch from the face of the stud. What protection is required?

    Answer: A steel shield plate at least 0.0575 inch (No. 16 gage) thick

    Under the IRC, Section P2603.2.1 requires steel shield plates where piping other than cast iron or galvanized steel passes through holes or notches less than 1-1/4 inches from the nearest edge of a framing member in a concealed location. The plates must be at least 0.0575 inch (No. 16 gage) thick. 3/4 inch is less than 1-1/4 inches, so a plate is required to protect the pipe from drywall screws and nails. The 8-mil sheathing is the corrosion rule in P2603.3, not protection from nails.

    Reference: 2018 International Residential Code, Section P2603.2.1

  4. Static water pressure from the main is 95 psi. What does the IRC require?

    Answer: A pressure-reducing valve at the connection to the water service

    Under the IRC, Section P2903.3.1 limits static water pressure in the building to 80 psi. Where main pressure exceeds 80 psi, an approved pressure-reducing valve (ASSE 1003 or CSA B356) must be installed on the domestic water branch main or riser at the connection to the water service pipe. A booster pump is for low pressure (P2903.3). An expansion tank controls thermal expansion, not main pressure.

    Reference: 2018 International Residential Code, Section P2903.3.1

  5. Under the IRC, a lawn irrigation system will have a fertilizer injector that adds chemicals to the water. What backflow protection must be installed on the potable supply?

    Answer: A reduced pressure principle backflow prevention assembly

    Under the IRC, Section P2902.5.3 allows an atmospheric vacuum breaker, pressure vacuum breaker or RPZ on an ordinary lawn irrigation system. Where chemicals are introduced, only a reduced pressure principle (RPZ) assembly is allowed. The chemicals make it a high hazard, and the RPZ is designed for high hazards under backpressure or backsiphonage. A double-check assembly is not listed for irrigation in this section.

    Reference: 2018 International Residential Code, Section P2902.5.3

  6. Using IRC Table P3004.1, what is the total drainage fixture unit load for one full-bath group with a 1.6 gpf water closet, a kitchen group (sink and dishwasher), and a laundry group (washer standpipe and laundry tub)?

    Answer: 10 d.f.u.

    Under the IRC, Table P3004.1 gives a full-bath group with a 1.6 gpf water closet 5 d.f.u., a kitchen group 2 d.f.u. and a laundry group 3 d.f.u. 5 + 2 + 3 = 10 d.f.u. Using 6 for the bath group (the value for a water closet over 1.6 gpf) gives 11. Adding the kitchen sink and dishwasher separately (2 + 2) instead of using the group value gives 12. Using a half-bath group (4) instead of a full-bath group gives 9.

    Reference: 2018 International Residential Code, Table P3004.1

  7. Under IRC Table P3105.1, a 1-1/2-inch trap arm slopes 1/4 inch per foot. What is the maximum developed length from the trap weir to the vent fitting?

    Answer: 6 feet

    Under the IRC, Table P3105.1 allows 6 feet for a 1-1/2-inch trap at 1/4 inch per foot. The table gives 5 feet for 1-1/4 inch, 8 feet for 2 inch, 12 feet for 3 inch and 16 feet for 4 inch. Self-siphoning fixtures such as water closets have no limit. Past these distances, the fall can drop the vent connection below the trap weir and siphon the trap.

    Reference: 2018 International Residential Code, Table P3105.1

  8. Each fixture trap must have a liquid seal of:

    Answer: Not less than 2 inches and not more than 4 inches

    Under the IRC, Section P3201.2 requires each fixture trap to have a liquid seal of at least 2 inches and not more than 4 inches. A seal shallower than 2 inches is easily lost to evaporation or pressure changes. A seal deeper than 4 inches holds solids and may not be self-cleaning.

    Reference: 2018 International Residential Code, Section P3201.2

  9. Under the IRC, a clothes washer standpipe must extend above its trap weir:

    Answer: Between 18 and 42 inches

    Under the IRC, Section P2706.1.2 requires standpipes to extend at least 18 inches and not more than 42 inches above the trap weir. A standpipe that is too short overflows when the washer pumps out. One that is too tall lets the discharge build speed and can siphon the trap. If a laundry tray drains into the standpipe, the standpipe must be at least 30 inches above its trap weir (P2706.1.2.1).

    Reference: 2018 International Residential Code, Section P2706.1.2

  10. A licensee must complete at least six hours of continuing professional education each year to renew. How many of those hours must be in health protection, energy conservation and water conservation?

    Answer: Three

    Texas Occupations Code §1301.404(b) requires at least six hours of continuing professional education annually to renew a license or endorsement. Three of the six hours must be in health protection, energy conservation and water conservation. Credit counts only for programs and courses approved by the executive director (§1301.404(d)).

    Reference: Texas Occupations Code Chapter 1301, §1301.404(b)

Sources

Questions last verified October 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.