Requirements at a glance
| License before this | Journeyman Plumber, held 2 years (or 1 year plus a DOL-approved apprenticeship) |
|---|---|
| Exam | 308 questions, 360 minutes (optional 30-minute break), 70%, written only |
| Provided at the exam | Calculator, sizing tables, conversion tables and formulas; otherwise closed book |
| Study | IPC + IFGC or UPC (2018), OSHA 1926, Texas Accessibility Standards, NFPA 54, Texas plumbing law and rules |
| Fees | $128.50 Pearson VUE exam + TSBPE application; $75 license |
Journeyman plumbers who have held the license for two years (or one year plus a Department of Labor-approved apprenticeship). A master license is required to become a responsible master plumber and run a plumbing business.
Official links
- TSBPE: Master Plumber license (opens in a new tab)
- TSBPE Master Plumber review course (opens in a new tab)
- Schedule with Pearson VUE (TSBPE) (opens in a new tab)
- Pearson VUE TSBPE candidate handbook (opens in a new tab)
- Texas Plumbing License Law (TSBPE copy) (opens in a new tab)
- Texas Accessibility Standards (TDLR) (opens in a new tab)
- OSHA 29 CFR 1926 (eCFR) (opens in a new tab)
How to get licensed, step by step
Meet the journeyman time
Hold a Journeyman Plumber license for two years, or one year if you've completed a Department of Labor-approved apprenticeship.
Apply to TSBPE
Submit the Master Plumber exam application online (faster than mail). Fingerprints are required if TSBPE doesn't already have them.
Pass the written exam at Pearson VUE
308 questions in 6 hours with an optional 30-minute break. There's no practical for the master license.
Schedule with Pearson VUE (TSBPE) (opens in a new tab)Pearson VUE TSBPE candidate handbook (opens in a new tab)
Get licensed, then become an RMP to run a business
Pay the $75 license fee. To pull permits and run a plumbing company, register as a Responsible Master Plumber with $300,000 of liability insurance.
How to prepare
- More than half the exam isn't plumbing code: OSHA, accessibility, LP gas, math, and law and rules are about 25 questions each. Don't spend all your time on the code book.
- OSHA questions come from specific parts of 29 CFR 1926: general (A–B), PPE (E), tools (I), welding (J), scaffolds (L) and excavations (P). Know trench protection triggers and soil types cold.
- The math is high-school level with a calculator provided: pipe volume, offsets, fall over run, pressure from height (0.433 psi per foot). Practice until it's quick, because 308 questions in 6 hours is about 70 seconds each.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
2018 International Plumbing Code + 2018 International Fuel Gas Code, or the 2018 Uniform Plumbing CodeEssential
The plumbing-code part of the exam. Study one set; the questions work with either.
ICC store (IPC) (opens in a new tab)Read IPC free (opens in a new tab)
OSHA 29 CFR Part 1926 (Subparts A–B, E, I, J, L and P)Essential
About 25 questions. Free from OSHA.
2012 Texas Accessibility Standards (Chapters 1, 2, 3 and 6)
About 25 questions on accessible fixtures: heights, clearances, grab bars, controls.
NFPA 54 National Fuel Gas Code (Chapters 5–10)
The LP-gas piping questions. NFPA offers free read-only access online.
Texas Plumbing License Law and TSBPE Board Rules
About 25 questions. The review course lists the exact sections.
Official reference list (as published by the testing agency)
- 2018 International Plumbing Code + 2018 International Fuel Gas Code, OR the 2018 Uniform Plumbing Code (study one)
- OSHA 29 CFR Part 1926: Subparts A–B, E, I, J, L and P
- 2012 Texas Accessibility Standards: Chapters 1, 2, 3 and 6
- NFPA 54 National Fuel Gas Code, Chapters 5–10 (LP gas piping)
- Texas Plumbing License Law (Occupations Code Chapter 1301) and TSBPE Board Rules (22 TAC Part 17)
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Plumbing Codes | 60 | |
| Water Heater Installation | 25 | |
| OSHA Construction Safety | 25 | |
| Texas Accessibility Standards | 25 | |
| Liquefied Petroleum Gas Piping | 25 | |
| Plumbing Math | 25 | |
| Plumbing License Law and Board Rules | 25 | |
| Pipe Sizing | 20 |
Exam day details
- Administered by Pearson VUE for the Texas State Board of Plumbing Examiners (TSBPE).
- Fee: $128.50 written exam (Pearson VUE) + TSBPE application; $75 license fee after you pass.
- Written exam only: 308 multiple-choice questions in 360 minutes at a Pearson VUE test center, with an optional 30-minute break. 70% to pass.
- Closed book, but you're given a calculator, sizing tables, conversion tables and formulas for the math and pipe-sizing questions.
- TSBPE's review course splits the written content into plumbing codes (60), water heaters (25), OSHA (25), Texas Accessibility Standards (25), LP gas (25), math (25) and law and rules (25), plus four pipe-sizing charts and a three-story drainage and vent design. That split dates from the older 210-question format, so our weights are an estimate.
- Like the journeyman exam, the code questions aren't specific to the IPC or UPC: study one.
- Our timed practice exams are 150 questions in 175 minutes, the same pace and topic mix as the real 308-question exam.
- Since September 1, 2025, journeymen can test after two years (or one year plus an approved apprenticeship), down from four.
Note: TSBPE's published topic split is for the older 210-question format, so our topic weights for the current 308-question exam are an estimate.
Frequently asked questions
How many questions are on the Texas Master Plumber exam?
308 multiple-choice questions in 6 hours, with an optional 30-minute break. You need 70% to pass.
Is the Texas master plumber exam open book?
No, but Pearson VUE gives you a calculator, sizing tables, conversion tables and formulas, so you don't need to memorize the pipe sizing charts.
What's on the Texas master plumber exam besides the plumbing code?
OSHA construction safety (29 CFR 1926), the Texas Accessibility Standards for plumbing fixtures, LP gas piping (NFPA 54), plumbing math and the Texas Plumbing License Law and Board Rules, plus pipe sizing and a drainage and vent design.
How long do I need to be a journeyman before the master exam?
Two years as a licensed journeyman, or one year plus completion of a Department of Labor-approved apprenticeship (since September 1, 2025).
Free questions with answers
Show all 10 free questions and answers
A reduced pressure principle backflow prevention assembly protects the potable supply to a commercial building's process equipment. Under both the IPC and the UPC, when must this assembly be tested?
Answer: At installation, after any repair or relocation, and at least once a year
Both codes require testable backflow assemblies to be tested when installed, immediately after they are repaired or relocated, and at least annually after that (IPC 312.10.2; UPC 603.2, which also lets the AHJ require more frequent tests). A one-time test at installation is the most common wrong belief; the three- and five-year intervals are invented. An assembly that fails must be repaired or replaced.
Reference: 2018 IPC / 2018 UPC, IPC 312.10.2; UPC 603.2
A steel gas line will be concealed in a stud wall above a ceiling. Which fitting may NOT be used in the concealed portion under both the IFGC and the UPC?
Answer: A union
Both codes limit fittings in concealed gas piping to types such as threaded elbows, tees and couplings, brazed or welded joints, and fittings listed for concealed use (IFGC 404.5; UPC 1210.3.1). Unions are not on either list, because their ground joints can loosen and leak where no one can see or service them. A union belongs in an exposed location, such as downstream of the appliance shutoff valve.
Reference: 2018 IFGC / 2018 UPC, IFGC 404.5; UPC 1210.3.1
Water heater #1 (40,000 Btu/h) shares a closet with a 45,000 Btu/h furnace. The closet gets combustion air from the adjoining hallway (indoor air, same story) through two permanent openings, each 9 in x 10 in. One opening begins 10 in below the ceiling and the other begins 8 in above the floor. Which statement is correct?
Answer: Located correctly, but each opening must be at least 100 sq in
For indoor combustion air, each of the two openings needs 1 sq in per 1,000 Btu/h of the total input of all appliances in the space, but never less than 100 sq in (IFGC 304.5.3.1; UPC 506.3). Total input = 40,000 + 45,000 = 85,000 Btu/h, so the ratio gives 85 sq in and the 100 sq in minimum governs. Each opening is 9 x 10 = 90 sq in, which beats 85 but is short of 100. The locations are right: one opening must begin within 12 in of the top and the other within 12 in of the bottom. Counting only the water heater is wrong because the furnace shares the space.
Reference: 2018 IFGC / 2018 UPC, IFGC 304.5.3.1; UPC 506.3
A horizontal fixture branch in an office building's public restroom serves 4 water closets (1.6 gpf, tank type), 3 lavatories and 2 urinals (1 gallon per flush). Use these values: public 1.6-gpf water closet = 4 DFU; private 1.6-gpf water closet = 3 DFU; lavatory = 1 DFU; urinal (1 gpf or less) = 2 DFU. Maximum DFU on a horizontal branch: 2-1/2 in = 12; 3 in = 20; 4 in = 160. What is the minimum size of the branch?
Answer: 4 inches
An office restroom is public use, so each water closet counts 4 DFU. Load = (4 x 4) + (3 x 1) + (2 x 2) = 16 + 3 + 4 = 23 DFU. A 3-inch horizontal branch is limited to 20 DFU, so the next size, 4 inches (160 DFU), is required. Using the private value of 3 DFU per water closet gives 12 + 3 + 4 = 19 DFU and wrongly points to 3 inches. The values come from IPC Table 709.1 and Table 710.1(2); the UPC uses its own tables (Table 702.1 and Table 703.2), but with the values given here the answer is fixed.
Reference: 2018 International Plumbing Code, Table 709.1; Table 710.1(2)
A 4-inch water main 120 feet long is full of water. Using 7.48 gallons per cubic foot and 8.34 pounds per gallon, about how much does the water in the main weigh?
Answer: 653 pounds
Volume of a cylinder = 0.7854 x D squared x L, with every dimension in feet. D = 4 in / 12 = 0.333 ft, so area = 0.7854 x 0.1111 = 0.08727 sq ft and volume = 0.08727 x 120 = 10.47 cu ft. Gallons = 10.47 x 7.48 = 78.3 gal. Weight = 78.3 x 8.34 = 653 pounds. 78 is the gallons, not the weight. 87 multiplies the cubic feet by 8.34 and skips the gallon conversion. 2,613 uses pi x D squared without dividing by 4, which gives four times the true area.
Reference: Plumbing math (cylinder volume and weight of water), V = 0.7854 x D^2 x L; 1 cu ft = 7.48 gal; 1 gal = 8.34 lb
A crew is working in a trench 6 feet deep. Under OSHA's excavation rules, a ladder, stairway, ramp or other safe means of egress must be placed so that workers travel no more than how far laterally to reach it?
Answer: 25 feet
29 CFR 1926.651(c)(2) requires a stairway, ladder, ramp or other safe means of egress in trench excavations 4 feet or more deep, located so that employees need no more than 25 feet of lateral travel. The 4-foot depth is what triggers the rule; 25 feet is the maximum travel distance. 15 feet is the maximum bottom width that still counts as a trench, not an egress distance.
Reference: 29 CFR Part 1926, Subpart P, 1926.651(c)(2)
A clay soil tests at 2.0 tsf unconfined compressive strength, but the trench runs beside a highway and the soil is subject to vibration from heavy traffic. How must the soil be classified?
Answer: Type B
Appendix A says no soil is Type A if it is fissured, subject to vibration from heavy traffic or pile driving, or previously disturbed. The Type B definition specifically includes soil that meets the Type A strength requirement but is fissured or subject to vibration. It is not Type C because it is not submerged, granular, or below 0.5 tsf.
Reference: 29 CFR Part 1926, Subpart P, Appendix A, (b) Definitions - Type A and Type B
Under the 2012 TAS, the centerline of an accessible water closet (not in an ambulatory compartment) must be how far from the side wall or partition?
Answer: 16 to 18 inches
2012 TAS 604.2 sets the centerline of the water closet 16 inches minimum to 18 inches maximum from the side wall or partition. The 17 to 19 inch range applies only in an ambulatory accessible compartment under 604.8.2, which is why it is a tempting distractor. 17 to 19 inches is also the seat height range in 604.4.
Reference: 2012 Texas Accessibility Standards, 604.2
A master plumber is asked by a second plumbing company to also serve as its Responsible Master Plumber. Under 22 TAC §367.5, for how many persons may a master plumber act as RMP of record at one time?
Answer: One
22 TAC §367.5(a) says a Master Plumber may act as the RMP of record for only one person at a time. The RMP definition in §361.1 also says the RMP allows the Master Plumber License to be used by only one plumbing company. Separate insurance does not change the limit.
Reference: 22 TAC Part 17 (TSBPE Rules), §367.5(a)
Underground metallic piping runs from an LP-gas storage container to a house. Under the 2018 IFGC, what isolation is required, and where must it be installed?
Answer: A dielectric fitting, installed above ground outdoors
2018 IFGC Section 404.10 requires metallic pipe or tubing carrying gas from an LP-gas container to have an approved dielectric fitting that electrically isolates the underground portion from the above-ground portion entering the building. The fitting must be installed above ground, outdoors. A bonding jumper does the opposite job and is not what this section requires.
Reference: 2018 International Fuel Gas Code, Section 404.10
Sources
- Pearson VUE: TSBPE Candidate Handbook (Aug 2025) (opens in a new tab)
- TSBPE: Master Plumber license (opens in a new tab)
- TSBPE: Master Plumber review course (opens in a new tab)
Questions last verified October 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.