Requirements at a glance
| Experience | 8,000 hours under a responsible master plumber (as an apprentice or Tradesman) |
|---|---|
| Training | 48 hours: two 6-hour courses + OSHA 10 + 8 hours residential + 18 hours commercial code (or an approved apprenticeship or AAS degree) |
| Exams | Written: 100 questions, 120 min, closed book, 70%. Practical: 6 tasks, 240 min (Tradesman licensees skip it). |
| Codes | Study either the 2018 IPC + IFGC or the 2018 UPC; the exam works with either |
| Fees | $40 TSBPE application + $68.50 Pearson VUE written exam; $40 license |
Plumber's apprentices or Tradesman plumbers with 8,000 hours under a responsible master plumber and 48 hours of required training.
Official links
How to get licensed, step by step
Log 8,000 hours and finish the training
Work under a responsible master plumber and complete the 48 hours of required training, unless you're exempt through a DOL apprenticeship or an approved degree.
Apply to TSBPE
Submit the Journeyman exam application with employer certification forms and the $40 fee.
Pass the written exam at Pearson VUE
100 questions in 120 minutes, closed book. Pick one code to study (IPC/IFGC or UPC).
Schedule with Pearson VUE (TSBPE) (opens in a new tab)Pearson VUE TSBPE candidate handbook (opens in a new tab)
Pass the practical (if you're not a Tradesman)
The Tradesman practical plus brazed copper, at TSBPE's Austin or Waco center within a year of the written. Then pay the $40 license fee.
How to prepare
- Pick one code and stick with it. TSBPE writes the exam so either the IPC/IFGC or the UPC gets you the right answer.
- It's closed book with less than a minute and a half per question, so you need values memorized: trap seals, slopes, vent heights, relief valve settings, air gaps and test pressures.
- Commercial work is on this exam: grease interceptors, indirect waste for food equipment, storm drainage and accessible fixtures.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
2018 International Plumbing Code (IPC) + 2018 International Fuel Gas Code (IFGC)Essential
One of the two code choices. Study this set or the UPC, not both.
ICC store (IPC) (opens in a new tab)Read IPC free (opens in a new tab)
2018 Uniform Plumbing Code (UPC)
The other code choice. It includes fuel gas in Chapter 12.
Texas Plumbing License Law and TSBPE Board Rules
The review course lists the exact sections that are tested.
Official reference list (as published by the testing agency)
- 2018 International Plumbing Code + 2018 International Fuel Gas Code, OR the 2018 Uniform Plumbing Code (study one; the exam isn't specific to either)
- Texas Plumbing License Law (Occupations Code Chapter 1301) and TSBPE Board Rules (22 TAC Part 17), sections listed in the TSBPE review course
- Manufacturers' installation instructions for PVC, copper (soldered and brazed), threaded steel and no-hub cast iron joints
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Definitions | 6 | |
| General Regulations | 10 | |
| Fixtures | 9 | |
| Water Heaters | 14 | |
| Water Supply and Distribution | 14 | |
| Sanitary Drainage | 12 | |
| Indirect Waste, Interceptors and Storm Drainage | 6 | |
| Vents | 11 | |
| Traps | 5 | |
| Fuel Gas | 7 | |
| Plumbing License Law and Board Rules | 6 |
Exam day details
- Administered by Pearson VUE for the Texas State Board of Plumbing Examiners (TSBPE).
- Fee: $68.50 written exam (Pearson VUE) + $40 TSBPE exam application fee; $40 license fee after you pass.
- Written exam: 100 multiple-choice questions in 120 minutes, closed book, at a Pearson VUE test center. 70% to pass.
- TSBPE says the exam isn't specific to either plumbing code: study the 2018 IPC and IFGC, or the 2018 UPC, not both. Our questions are written to have the same answer under both codes; where the codes differ, the question says which code it uses.
- Practical exam (TSBPE, Austin or Waco): the Tradesman tasks plus brazed copper. Current Tradesman licensees skip the practical.
- Up to 5 written attempts within a year of authorization, with waits of 30, 60 and then 90 days after each failure.
- TSBPE doesn't publish question counts per topic; the weights shown are our estimate from its review course and required training hours.
Note: TSBPE doesn't publish how many questions come from each topic, so our topic weights are estimates based on its review course and required training hours.
Frequently asked questions
Do I study the IPC or the UPC for the Texas journeyman plumbing exam?
Either one. TSBPE says the exam isn't specific to any one code: study the 2018 IPC with the 2018 IFGC, or the 2018 UPC. Questions are written so the answer is the same under both.
Is the Texas Journeyman Plumber exam open book?
No. It's 100 questions in 120 minutes with no books or notes, so you need the common code values (slopes, trap seals, vent heights, relief valve settings, test pressures) memorized.
Do I have to take the practical if I'm already a Tradesman plumber?
No. Current Tradesman Plumber-Limited licensees take only the written Journeyman exam.
Free questions with answers
Show all 10 free questions and answers
A journeyman's license expired 60 days ago. Under the Plumbing License Law, how can the license be renewed?
Answer: By paying 1-1/2 times the normally required renewal fee
Occupations Code §1301.403(b) lets a person whose license has been expired 90 days or less renew by paying 1-1/2 times the normal renewal fee. If it has been expired more than 90 days but less than two years, §1301.403(c) sets the fee at two times the normal fee. After two years or more, §1301.403(d) says it cannot be renewed and the person must meet the requirements for an original license, including the exam.
Reference: Texas Occupations Code ch. 1301 (Plumbing License Law), §1301.403(b)-(d)
What is the maximum vertical distance permitted from a lavatory's waste outlet down to the weir of its trap?
Answer: 24 inches
Both codes limit the vertical drop between the fixture outlet and the trap weir (the tailpiece length) to 24 inches (IPC 1002.1; UPC 1001.2). A longer tailpiece lets the waste build up speed and can siphon the trap. The 30-inch figure is the IPC's horizontal limit from outlet to trap inlet and the spacing limit for outlets sharing one trap, not the vertical limit.
Reference: 2018 IPC / 2018 UPC, IPC 1002.1; UPC 1001.2
A gas-fired water heater that is not listed as flammable-vapor ignition resistant is installed in a residential garage. How high above the floor must its burners and ignition source be?
Answer: 18 inches
Both the IFGC and the UPC require the ignition source of an appliance in a garage to be at least 18 inches above the floor (IFGC 305.3; UPC 507.13). Gasoline vapors are heavier than air and collect near the floor. The requirement does not apply to appliances listed as flammable-vapor ignition resistant (FVIR).
Reference: 2018 IFGC / 2018 UPC, IFGC 305.3; UPC 507.13
Static water pressure at a new building is measured at 95 psi. What does the code require?
Answer: A pressure-reducing valve to bring the static pressure in the building down to 80 psi or less
Both codes require an approved pressure-reducing valve (regulator) with a strainer where static pressure exceeds 80 psi, reducing the building's static pressure to 80 psi or less (IPC 604.8; UPC 608.2). There is no 100-psi threshold and the code does not require 60 psi. Once a PRV is installed, thermal expansion control is also needed, but an expansion tank alone does not lower supply pressure.
Reference: 2018 IPC / 2018 UPC, IPC 604.8; UPC 608.2
What is the minimum slope for a 2-inch horizontal drainage pipe?
Answer: 1/4 inch per foot
A 2-inch horizontal drain needs at least 1/4 inch per foot (2 percent) slope under both codes (IPC Table 704.1, which applies 1/4 inch to pipe 2-1/2 inches and smaller; UPC 708.1). The flatter 1/8-inch slope is allowed only for larger pipe: 3 to 6 inches in the IPC, and 4 inches and larger with AHJ approval in the UPC.
Reference: 2018 IPC / 2018 UPC, IPC Table 704.1; UPC 708.1
A horizontal branch vent will run across a wall to connect to the rest of the venting system. It serves a group of lavatories whose flood-level rims are 31 inches above the finished floor. What is the lowest height above the floor at which the horizontal section of vent may run?
Answer: 37 inches
Both codes require a vent to rise at least 6 inches above the flood-level rim of the highest fixture served before it runs horizontally or connects to another vent (IPC 905.4, 905.5; UPC 905.3). 31 + 6 = 37 inches above the floor. A horizontal vent any lower could fill with waste if the drain backs up and stop working as a vent. 35 inches applies only a 4-inch rise, and 43 inches adds 12 inches.
Reference: 2018 IPC / 2018 UPC, IPC 905.4, 905.5; UPC 905.3
Which type of control valve is required for an individual shower or tub-shower combination?
Answer: A pressure-balance, thermostatic, or combination pressure-balance/thermostatic valve meeting ASSE 1016 (or ASME A112.18.1/CSA B125.1)
Both codes require individual shower and tub-shower valves to be pressure-balance, thermostatic or combination types conforming to ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1, installed at the point of use (IPC 412.3; UPC 408.3). These valves protect against scalding and thermal shock when pressure changes. The water heater thermostat is not an acceptable control.
Reference: 2018 IPC / 2018 UPC, IPC 412.3; UPC 408.3
An appliance connector supplies a gas range. Where must the appliance shutoff valve be located?
Answer: Within 6 feet of the appliance and upstream of the connector
Both codes require each appliance to have an accessible manual shutoff valve within 6 feet of the appliance, installed upstream of the connector (IFGC 409.5.1; UPC 1212.6). The IFGC also requires the valve to be in the same room as the appliance. A valve downstream of the connector wouldn't let you shut off a leaking connector.
Reference: 2018 IFGC / 2018 UPC, IFGC 409.5.1; UPC 1212.6
A new copper water distribution system is ready for its pressure test. Which test meets both codes?
Answer: Water at not less than the system's working pressure, or air at not less than 50 psi, held at least 15 minutes
Both codes test water supply piping with water at a pressure not less than the working pressure, or (for non-plastic piping) air at not less than 50 psi, held for at least 15 minutes without leaks (IPC 312.5; UPC 609.4). The 5-psi air test and the 10-foot water head test are the DWV tests, not water supply tests.
Reference: 2018 IPC / 2018 UPC, IPC 312.5; UPC 609.4
A commercial kitchen has a grease interceptor. Which fixture is prohibited from discharging into it?
Answer: A food waste disposer
Both codes prohibit a food waste disposer from discharging into a grease interceptor (IPC 1003.3.2; UPC 1014.1.3, which also bars dishwashers). The ground-up food solids would fill the interceptor and reduce its grease-separating capacity. Pot sinks, prerinse sinks and floor sinks serving cooking equipment are the grease-laden sources the interceptor is meant to serve.
Reference: 2018 IPC / 2018 UPC, IPC 1003.3.2; UPC 1014.1.3
Sources
- Pearson VUE: TSBPE Candidate Handbook (Aug 2025) (opens in a new tab)
- TSBPE: examinations and required training (opens in a new tab)
- TSBPE: Journeyman Plumber license (opens in a new tab)
- Pearson VUE: TSBPE Journeyman review course (opens in a new tab)
Questions last verified October 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.