Texas licensing exam

Texas Residential Wireman Exam: Practice Test & Licensing Guide

TDLR's Residential Wireman exam on the 2026 NEC: 80 scored questions on dwelling wiring, 70% to pass.

Questions
85
Time limit
4.333333333333333 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Branch Circuit Calculations and Conductors

Under the 2026 NEC, what is the minimum number of 120-volt, 15-ampere general lighting branch circuits required for a 2,600 ft² dwelling unit?

Requirements at a glance

ScopeElectrical work in single-family and multifamily dwellings up to four stories
Experience4,000 hours under a Texas master electrician or residential wireman, or an approved career and technology education program
Exam85 items (80 scored), 260 minutes, 70% to pass
Code book2026 NEC (soft-bound, publisher tabs only)
Fees$20 TDLR application + $64 PSI exam

Electricians who wire houses and multifamily dwellings up to four stories: 4,000 hours of on-the-job training under a Texas master electrician or residential wireman, or an approved career and technology education program.

How to get licensed, step by step

  1. Work as a licensed apprentice

    Get an Apprentice Electrician license from TDLR and log 4,000 hours on residential work, or finish an approved career and technology education (CTE) program.

    TDLR: Apprentice Electrician license (opens in a new tab)

  2. Apply to TDLR

    Mail the Residential Wireman application with Experience Verification Forms (or CTE proof) and the $20 fee.

    TDLR: apply for a Residential Wireman license (opens in a new tab)

  3. Schedule with PSI

    Once TDLR approves you, schedule at a PSI test center. You have one year from your application to pass. The exam is offered in English and Spanish.

    Schedule with PSI (TDLR exams) (opens in a new tab)PSI candidate bulletin (2026 NEC) (opens in a new tab)

  4. Pass the exam

    80 scored questions in 240 minutes (plus 5 unscored with 20 extra minutes), 70% to pass.

    TDLR: electrician exam information (opens in a new tab)

How to prepare

  • Bring your own soft-bound 2026 NEC. You can highlight and write notes in it beforehand, but only publisher-made permanent tabs are allowed: no homemade tabs, no NEC Handbook, no loose paper.
  • Use the 2026 NEC. The exam switched editions on September 1, 2026, and some articles moved (for example, load calculations are now in Article 120). Study guides written for the 2023 NEC will send you to the wrong place.
  • Read the bulletin's rules: assume copper conductors and ignore code exceptions and optional calculation methods unless the question tells you to use them.
  • Services (16) and branch circuits (14) are 30 of the 80 questions. Know dwelling load calculations in Article 120, GFCI and AFCI rules in 210.8 and 210.12, and receptacle placement in 210.52.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2026 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC), 2026 Edition (bring your own soft-bound copy)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Definitions, Calculations, Theory and Plans8
Services, Service Equipment and Separately Derived Systems16
Feeders7
Branch Circuit Calculations and Conductors14
Wiring Methods and Materials10
Equipment and Devices12
Motors and Generators2
Control Devices and Disconnecting Means2
Special Occupancies, Equipment and Conditions7
Renewable Energy (PV and EV Charging)2

The outline totals 80; the other items on the 85-question exam are unscored or unassigned.

Exam day details

  • Administered by PSI Services for the Texas Department of Licensing and Regulation (TDLR).
  • Fee: $64 (PSI), plus TDLR's $20 application fee.
  • Since September 1, 2026 the exam is based on the 2026 NEC.
  • One part: 80 scored items in 240 minutes, plus 5 unscored items with 20 extra minutes.
  • Open book with the same rules as the journeyman exam: your own soft-bound NEC, highlighted or noted beforehand, publisher tabs only, no NEC Handbook.
  • A Residential Wireman may only do electrical work in single-family and multifamily dwellings up to four stories.
  • Unless a question says otherwise, all conductors are copper, and you shouldn't apply code exceptions or optional calculation methods.
  • In TDLR's fiscal year 2025, 30% of Residential Wireman attempts passed.

Frequently asked questions

What can a Texas Residential Wireman do?

Electrical work in single-family and multifamily dwellings up to four stories, under an electrical contractor. Commercial work needs a Journeyman Electrician license.

How many questions are on the Texas Residential Wireman exam?

85 items (80 scored, 5 unscored) in 260 minutes, open book with the 2026 NEC. You need 70%. Services and branch circuits are 30 of the 80 scored questions.

How many hours do I need for the Residential Wireman license?

4,000 hours of on-the-job training under a Texas master electrician or residential wireman, or completion of an approved career and technology education program.

Free questions with answers

Show all 10 free questions and answers
  1. Under the 2026 NEC, what is the minimum number of 120-volt, 15-ampere general lighting branch circuits required for a 2,600 ft² dwelling unit?

    Answer: 5

    New Section 120.13 requires a unit load of at least 3 VA/ft² when calculating the minimum number of dwelling branch circuits. 2,600 x 3 = 7,800 VA; 7,800 / 120 V = 65 A; 65 / 15 A = 4.33, which must be rounded up to 5 circuits. Using the 2 VA/ft² service/feeder value (120.41) gives only 3 circuits, and dividing by 20-A circuits gives 4. Never round a circuit count down.

    Reference: 2026 National Electrical Code (NFPA 70), Section 120.13

  2. A 200-ampere, 120/240-volt single-phase service supplies the entire load of a one-family dwelling. No correction or adjustment factors apply, and the copper service conductors are rated 75°C. Under 310.12(A), what is the minimum conductor size?

    Answer: 2/0 AWG

    Section 310.12(A) allows dwelling service conductors for a 100-400 A service supplying the entire dwelling load to have an ampacity of not less than 83% of the service rating: 200 A x 0.83 = 166 A. In the 75°C copper column of Table 310.16, 1/0 AWG is 150 A (too small) and 2/0 AWG is 175 A, so 2/0 AWG is the minimum. 3/0 AWG (200 A) is what you would get without the 83% allowance. The 2026 text limits the table method to conductors or cables rated 75°C or higher.

    Reference: 2026 National Electrical Code (NFPA 70), Section 310.12(A) and Table 310.16

  3. In a dwelling kitchen, an electrician wants to put a receptacle on the end panel of an island base cabinet, 10 in. below the countertop surface. Under the 2026 NEC, is this permitted?

    Answer: No, unless it is installed in a drawer, because receptacles beneath countertops are not permitted within 24 in. of the countertop

    New 210.52(C)(4) prohibits receptacle outlets on cabinet sides and wall surfaces below countertops and work surfaces within 24 in. of the countertop, to keep appliance cords from hanging over the edge. Exception No. 1 permits receptacles installed in a drawer. GFCI protection or a separate circuit does not cure the location problem, and islands may have receptacles on or above the work surface (or must have electrical provisions for future ones under 210.52(C)(2)).

    Reference: 2026 National Electrical Code (NFPA 70), Section 210.52(C)(4)

  4. A nonmetallic device box with no internal cable clamps contains three 14/2 NM cables with ground (two insulated 14 AWG conductors in each cable) and one single-pole switch. The splices use twist-on connectors. Using 314.16(B), what minimum box volume is required?

    Answer: 18.0 in³

    Count 14 AWG volume units: 6 insulated conductors = 6; all equipment grounding conductors together = 1 [314.16(B)(5)]; the switch yoke = 2 [314.16(B)(4)]. Total 9 x 2.00 in³ (Table 314.16(B)(1), 14 AWG) = 18.0 in³. The 2026 text of 314.16(B) confirms splicing connectors need no allowance. Counting each ground separately gives 11 units (22.0 in³), counting the switch as 1 gives 16.0 in³, and 20.25 in³ uses the 12 AWG volume of 2.25 in³.

    Reference: 2026 National Electrical Code (NFPA 70), Section 314.16(B) and Table 314.16(B)(1)

  5. A permanently connected EVSE in a dwelling garage has a maximum load of 42 amperes. What is the minimum standard rating of the overcurrent device for its branch circuit?

    Answer: 60 A

    Section 625.41 treats EV charging as a continuous load, so the overcurrent device must be rated at least 125% of the maximum load: 42 A x 1.25 = 52.5 A. The next standard size in Table 240.6(A) above 52.5 A is 60 A. 50 A is below 52.5 A, 45 A ignores the 125% factor, and 70 A is larger than the minimum.

    Reference: 2026 National Electrical Code (NFPA 70), Section 625.41 and Table 240.6(A)

  6. A 2,200 ft² one-family dwelling (120/240 V) has two small-appliance circuits, one laundry circuit, a 12-kW range, a 5-kW dryer, and four fastened-in-place appliances: 1.2-kW dishwasher, 0.9-kW disposal, 4.5-kW water heater and 1.5-kW built-in microwave. Heat is a 10-kW electric furnace and cooling is a 4.8-kVA air conditioner. Using the 2026 NEC standard method, what is the calculated service load?

    Answer: 142.3 A

    Lighting 2,200 x 2 VA = 4,400 VA (120.41) + 3,000 VA small-appliance + 1,500 VA laundry = 8,900 VA. Table 120.45: 3,000 + (5,900 x 0.35) = 5,065 VA. Four fastened-in-place appliances total 8,100 VA x 75% (120.53) = 6,075 VA. Range 8,000 VA (Table 120.55, Col. C). Dryer 5,000 VA (120.54). Heat and A/C are noncoincident, so only the larger 10,000 VA counts (120.6). Total 34,140 VA / 240 V = 142.3 A. Skipping the 75% factor gives 150.7 A, adding both heat and A/C gives 162.3 A, and using 3 VA/ft² gives 145.5 A.

    Reference: 2026 National Electrical Code (NFPA 70), Section 120.41, Table 120.45, Section 120.53, Section 120.54, Table 120.55, Section 120.6

  7. Under 210.8(A), which of these dwelling receptacles must have GFCI protection?

    Answer: A 125-volt receptacle in a garage

    Section 210.8(A)(2) lists garages as a location where all 125-volt through 250-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to ground need GFCI protection. Bedrooms, hallways and living rooms are not on the 210.8(A) list unless another item (such as a sink within 6 ft) applies; those areas fall under the AFCI rule in 210.12(B) instead.

    Reference: 2026 National Electrical Code (NFPA 70), Section 210.8(A)(2)

  8. A homeowner wants the main panel installed high on a garage wall where it can only be reached by standing on a portable ladder. Under the Article 100 definition, is the panel readily accessible?

    Answer: No, because reaching it requires a portable ladder

    Article 100 defines readily accessible as capable of being reached quickly for operation, renewal, or inspection without those requiring ready access having to use tools other than keys, climb over or under, remove obstacles, or resort to portable ladders. The 2026 edition reworded the definition for readability but kept these conditions. Needing a ladder fails the definition even though no tools are needed.

    Reference: 2026 National Electrical Code (NFPA 70), Article 100, Accessible, Readily (Readily Accessible)

  9. At a dwelling, a 125-volt, 20-ampere receptacle is 15 ft from the inside wall of a permanently installed pool. What does 680.22(A)(4) require?

    Answer: GFCI protection, because it is within 20 ft of the pool

    Section 680.22(A)(4) requires GFCI protection complying with 680.5(B) for all receptacles within 20 ft of the inside walls of a pool when supplied by branch circuits rated 150 volts or less to ground and 60 amperes or less single-phase (or 100 amperes or less 3-phase). At 15 ft the receptacle is inside that zone. The 10 ft distance applies to spas and hot tubs in 680.43(A)(2).

    Reference: 2026 National Electrical Code (NFPA 70), Section 680.22(A)(4) and Section 680.5(B)

  10. A six-unit apartment building has one 5.5-kW electric clothes dryer in each unit, all on the same feeder. Using 120.54 and Table 120.54 in the 2026 NEC, what is the dryer demand load?

    Answer: 24,750 W

    Each dryer is counted at its nameplate rating or 5,000 W, whichever is larger: 5,500 W x 6 = 33,000 W. The 2026 Table 120.54 demand factor for 6 dryers is 75%: 33,000 x 0.75 = 24,750 W. 26,400 W uses the 80% factor for 3-5 dryers; 33,000 W uses no demand factor; 22,500 W wrongly uses 5,000 W per dryer.

    Reference: 2026 National Electrical Code (NFPA 70), Section 120.54 and Table 120.54

Sources

Questions last verified October 8, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.