Texas licensing exam

Texas Journeyman Electrician Exam: Practice Test & Licensing Guide

TDLR's two-part Journeyman Electrician exam on the 2026 NEC: an NEC Knowledge part and a Calculations part, 70% on each.

Questions
85
Time limit
4 hours
Passing score
70% per part

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Services, Service Equipment and Separately Derived Systems

A new one-family dwelling is being wired under the 2026 NEC. Where must the service disconnect be located?

Requirements at a glance

License before thisApprentice Electrician (TDLR)
Experience7,000 hours of on-the-job training under a Texas master electrician to test; 8,000 for the license
ExamTwo parts: NEC Knowledge (59 items, 130 min) + Calculations (26 items, 110 min), 70% on each
Code book2026 NEC (soft-bound, publisher tabs only)
Fees$30 TDLR application + $78 PSI exam (both parts)

Apprentice electricians with at least 7,000 hours of on-the-job training under a Texas master electrician (8,000 hours are required for the license itself).

How to get licensed, step by step

  1. Work as a licensed apprentice

    Get an Apprentice Electrician license from TDLR and log on-the-job training under a Texas master electrician.

    TDLR: Apprentice Electrician license (opens in a new tab)

  2. Apply to TDLR

    With at least 7,000 hours, mail the Journeyman Electrician application with Experience Verification Forms signed by each supervising master, plus the $30 fee.

    TDLR: apply for a Journeyman Electrician license (opens in a new tab)

  3. Schedule with PSI

    Once TDLR approves you, schedule both parts at a PSI test center. You have one year from your application to pass. The exam is offered in English and Spanish.

    Schedule with PSI (TDLR exams) (opens in a new tab)PSI candidate bulletin (2026 NEC) (opens in a new tab)

  4. Pass both parts

    NEC Knowledge (59 items, 130 minutes) and Calculations (26 items, 110 minutes), 70% on each. If you fail a part, you retake it for $78.

    TDLR: electrician exam information (opens in a new tab)

  5. Get your license

    TDLR issues the license once you pass and have 8,000 hours. Electrician licenses renew every year.

How to prepare

  • Bring your own soft-bound 2026 NEC. You can highlight and write notes in it beforehand, but only publisher-made permanent tabs are allowed: no homemade tabs, no NEC Handbook, no loose paper.
  • Use the 2026 NEC. The exam switched editions on September 1, 2026, and some articles moved (for example, load calculations are now in Article 120). Study guides written for the 2023 NEC will send you to the wrong place.
  • Practice each part under its own clock. Time doesn't carry over from the NEC Knowledge part to the Calculations part, and you must pass both.
  • Read the bulletin's rules: assume copper conductors and ignore code exceptions and optional calculation methods unless the question tells you to use them.
  • Only about 1 in 4 attempts passes each part (TDLR, fiscal 2025). Branch circuits, wiring methods and equipment are 30 of the 56 scored knowledge questions; know Chapters 2 through 4 cold.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2026 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC), 2026 Edition (bring your own soft-bound copy)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
NEC Knowledge(59 items, 56 scored · 130 min)
Definitions, Theory and Plans3
Services, Service Equipment and Separately Derived Systems6
Feeders3
Branch Circuits and Conductors10
Wiring Methods and Materials10
Equipment and Devices10
Motors and Generators5
Control Devices and Disconnecting Means1
Special Occupancies, Equipment and Conditions6
Renewable Energy (PV and EV Charging)2
Calculations(26 items, 24 scored · 110 min)
Electrical Theory Calculations2
Service and Transformer Calculations4
Feeder Calculations3
Branch Circuit and Conductor Calculations4
Raceway and Box Fill Calculations2
Equipment and Appliance Calculations2
Motor and Generator Calculations2
Disconnecting Means Calculations1
Special Occupancy Calculations3
EV Charging and PV Calculations1

The parts are timed and scored separately, and you must pass each one. Our simulations score each part the same way and give you the combined time (240 minutes).

Exam day details

  • Administered by PSI Services for the Texas Department of Licensing and Regulation (TDLR).
  • Fee: $78 for both parts (PSI), plus TDLR's $30 application fee. Retakes are $78.
  • Since September 1, 2026 the exam is based on the 2026 NEC. Earlier study material written for the 2023 NEC uses different article and section numbers in places.
  • Two parts: NEC Knowledge (59 items, 3 unscored, 130 minutes) and Calculations (26 items, 2 unscored, 110 minutes). Unused time doesn't carry over, and you must score 70% on each part.
  • Open book: bring your own soft-bound NEC. It may be highlighted and noted beforehand and tabbed only with publisher-made permanent tabs. The NEC Handbook, homemade tabs and loose paper aren't allowed.
  • Unless a question says otherwise, all conductors are copper, and you shouldn't apply code exceptions or optional calculation methods.
  • In TDLR's fiscal year 2025, only 24% of NEC Knowledge attempts and 21% of Calculations attempts passed.
  • Offered in English and Spanish at PSI test centers across Texas. You have one year from your application to pass.

Frequently asked questions

What NEC edition is the Texas journeyman exam based on?

The 2026 National Electrical Code, since September 1, 2026. You bring your own soft-bound copy; it can be highlighted and noted in advance but only tabbed with the publisher's permanent tabs.

How many questions are on the Texas Journeyman Electrician exam?

85 items in two parts: NEC Knowledge (59 items, 130 minutes) and Calculations (26 items, 110 minutes). A few items in each part are unscored. You need 70% on each part.

How hard is the Texas journeyman electrician exam?

Hard. In fiscal year 2025, about 24% of NEC Knowledge attempts and 21% of Calculations attempts passed (TDLR statistics). Most people who fail aren't short on knowledge; they run out of time finding things in the code.

How many hours do I need to take the exam?

At least 7,000 hours of on-the-job training under a Texas master electrician to sit for the exam, and 8,000 hours for the license.

Free questions with answers

Show all 10 free questions and answers
  1. A new one-family dwelling is being wired under the 2026 NEC. Where must the service disconnect be located?

    Answer: In a readily accessible outdoor location on or within sight of the dwelling

    Section 230.70(A)(1), new in the 2026 NEC, requires service disconnects for one- and two-family dwellings to be in a readily accessible outdoor location, either on the dwelling or within sight of it (110.29). The 2026 edition deleted 230.85 and folded the emergency-disconnect rules into 230.70. The only exception allows the service disconnect elsewhere when an emergency disconnect is installed under 225.41, so a warning label alone never satisfies the rule. "Inside nearest the point of entrance" is the rule in 230.70(A)(2) for buildings other than one- and two-family dwellings.

    Reference: 2026 National Electrical Code (NFPA 70), Section 230.70(A)(1)

  2. A 480Y/277-volt, solidly grounded wye system has a feeder disconnect rated 1200 amperes. Under Section 215.10(A), what protection is required for this feeder disconnect?

    Answer: Ground-fault protection of equipment in accordance with 230.95

    Section 215.10(A) requires ground-fault protection of equipment, in accordance with 230.95, on each feeder disconnect rated 1000 amperes or more on a solidly grounded wye system of more than 150 volts to ground but not more than 1000 volts phase-to-phase. A 480Y/277-volt system is 277 volts to ground, and the disconnect is 1200 amperes, so GFPE is required. Exceptions cover continuous industrial processes and GFPE already provided upstream.

    Reference: 2026 National Electrical Code (NFPA 70), Section 215.10(A)

  3. At a dwelling, a 120/240-volt, single-phase, 60-ampere branch circuit supplies an outdoor receptacle outlet used for a portable welder. Under the 2026 NEC outdoor-outlet rule, is GFCI protection required for this outlet?

    Answer: Yes, the 2026 NEC covers outdoor outlets on branch circuits rated 60 amperes or less, 150 volts or less to ground

    In the 2026 NEC, Section 210.8(F) requires GFCI protection for dwelling outdoor outlets supplied by single-phase branch circuits rated 150 volts or less to ground and 60 amperes or less. Earlier editions stopped at 50 amperes, which is the tempting wrong answer. A 120/240-volt system is 120 volts to ground, so this 60-ampere outlet is covered. Separate exceptions cover lighting outlets and listed HVAC equipment.

    Reference: 2026 National Electrical Code (NFPA 70), Section 210.8(F)

  4. A switchboard rated 1600 amperes and 8 ft wide contains overcurrent devices. What does Section 110.26(C)(2) require for access to its working space?

    Answer: One entrance at least 24 in. wide and 6 1/2 ft high at each end of the working space

    Section 110.26(C)(2) applies to equipment rated 1200 amperes or more that is over 6 ft wide and contains OCPDs, switching devices, or control devices. It requires an entrance to and egress from the working space at least 24 in. wide and 6 1/2 ft high at each end. Exceptions allow a single entrance where there is a continuous, unobstructed way out, or where the working space is double the depth required by 110.26(A)(1).

    Reference: 2026 National Electrical Code (NFPA 70), Section 110.26(C)(2)

  5. A 10-hp, 230-volt, three-phase motor has a nameplate full-load current of 26 amperes. Which value must be used to size its branch-circuit conductors?

    Answer: The full-load current from Table 430.250

    Section 430.6(A)(1) requires the table values (Tables 430.247 through 430.250) to be used instead of the nameplate current when sizing conductor ampacity, switch ratings, and branch-circuit short-circuit and ground-fault protection. The nameplate current is used for overload protection under 430.32. Locked-rotor current is used for things like disconnect horsepower equivalents, not for conductor ampacity.

    Reference: 2026 National Electrical Code (NFPA 70), Section 430.6(A)(1)

  6. At a permanently installed swimming pool, 125-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to ground need GFCI protection when they are located within what distance of the inside walls of the pool?

    Answer: 20 ft

    Section 680.22(A)(4) requires GFCI protection for all receptacles within 20 ft of the inside walls of a pool. For circuits rated 150 volts or less to ground, this covers single-phase circuits up to 60 amperes and three-phase circuits up to 100 amperes. 6 ft is the minimum distance from the pool wall for receptacles, which is a different rule.

    Reference: 2026 National Electrical Code (NFPA 70), Section 680.22(A)(4)

  7. A portable EV charger plugs into a new 50-ampere, 125/250-volt receptacle in a garage. What does the 2026 NEC require of that 50-ampere receptacle?

    Answer: It must be listed and marked for EVSE use

    Section 625.44(A), revised in the 2026 NEC, requires 30-, 50-, and 60-ampere receptacles that supply portable EVSE to be listed and marked for EVSE (and WPTE) use. The change responds to receptacle failures from long hours of continuous high current. 15- and 20-ampere receptacles do not need this marking. Locking receptacles are required only for certain 277/480-volt connections.

    Reference: 2026 National Electrical Code (NFPA 70), Section 625.44(A)

  8. A 1800 ft² one-family dwelling (120/240 V) has two small-appliance circuits, one laundry circuit, a 12-kW range, a 5.5-kW dryer, a 1.2-kW dishwasher, a 0.9-kW disposal, a 4.5-kW water heater, a 10-kW electric furnace, and a 5-kVA air conditioner. Using the 2026 NEC standard method, what is the calculated service load in amperes?

    Answer: 145.4 A

    Lighting = 1800 x 2 VA = 3600 VA. Add small-appliance (3000 VA) and laundry (1500 VA) for 8100 VA. Table 120.45: 3000 + (5100 x 0.35) = 4785 VA. Fastened-in-place appliances: 1200 + 900 + 4500 = 6600 VA at 100%, because there are fewer than four (120.53). Dryer = 5500 VA (120.54). Range = 8000 VA (Table 120.55, Col. C). Heat and AC are noncoincident, so only the larger 10,000 VA is counted (120.6). Total = 34,885 VA / 240 V = 145.4 A. Using 3 VA/ft² gives 148.0 A. Adding both heat and AC gives 166.2 A. Applying 75% to only three appliances gives 138.5 A.

    Reference: 2026 National Electrical Code (NFPA 70), Section 120.41, Table 120.45, Section 120.53, Section 120.54, Table 120.55, Section 120.6

  9. Six current-carrying 12 AWG THHN copper conductors are in one EMT raceway at a normal 30°C ambient. Using the 90°C column of Table 310.16 and the adjustment factors of Table 310.15(C)(1), what is the adjusted ampacity of each conductor?

    Answer: 24 A

    Table 310.16 gives 12 AWG THHN at 30 A (90°C column). Table 310.15(C)(1) requires an 80 percent adjustment for 4-6 current-carrying conductors. 30 x 0.80 = 24 A. 20 A is the OCPD limit for 12 AWG copper in 240.4(D), not the adjusted ampacity. 25 A is the 60°C column value.

    Reference: 2026 National Electrical Code (NFPA 70), Table 310.16 and Table 310.15(C)(1)

  10. A 4 in. x 1 1/2 in. square metal box (21.0 in³ from Table 314.16(A)) will contain only 12 AWG conductors, with no devices, clamps, or fittings. What is the maximum number of 12 AWG conductors permitted?

    Answer: 9

    Table 314.16(B)(1) assigns 2.25 in³ to each 12 AWG conductor. 21.0 / 2.25 = 9.33, so 9 conductors is the maximum (always round down). Table 314.16(A) also lists this box as holding 9 No. 12 conductors. 10 is the answer for 14 AWG (21.0 / 2.0 = 10.5).

    Reference: 2026 National Electrical Code (NFPA 70), Table 314.16(A) and Table 314.16(B)(1)

Sources

Questions last verified October 7, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.