Requirements at a glance
| Experience | 48 months under a licensed ACR contractor in the past 72 months, or 12 months as a certified technician + 36 months |
|---|---|
| Exam | Class A: 120 scored items, 240 min, $74. Class B: 100 scored items, 180 min, $60. 70% to pass. |
| Books | 2024 IMC or UMC, 2024 IFGC, ACCA Manuals J/D/S, Modern Refrigeration, Texas ACR law and rules |
| After passing | Certificate of general liability insurance (higher limits for Class A) |
| Fees | $115 TDLR application + PSI exam fee |
Anyone who runs an HVAC contracting business in Texas: 48 months of supervised ACR experience in the past 72 months (or 12 months as a certified technician plus 36 months of experience).
Official links
- TDLR: apply for an ACR contractor license (opens in a new tab)
- TDLR: ACR exam information (opens in a new tab)
- PSI ACR candidate bulletin (opens in a new tab)
- Schedule with PSI (TDLR exams) (opens in a new tab)
- Texas Occupations Code Chapter 1302 (opens in a new tab)
- TDLR ACR rules (16 TAC Chapter 75) (opens in a new tab)
How to get licensed, step by step
Choose Class A or Class B
Class A covers any size equipment. Class B is limited to cooling systems of 25 tons or less and heating systems of 1.5 million Btu/h or less. The Environmental Air endorsement covers comfort heating and cooling.
TDLR: apply for an ACR contractor license (opens in a new tab)
Apply to TDLR
Submit the contractor application with your experience verification and the $115 fee. You must pass the exam within one year of applying.
TDLR: apply for an ACR contractor license (opens in a new tab)
Schedule with PSI
Once approved, schedule at a PSI test center. The exam is open book and offered in English and Spanish. Retakes are unlimited during your eligibility year.
Schedule with PSI (TDLR exams) (opens in a new tab)PSI ACR candidate bulletin (opens in a new tab)
Send proof of insurance
After you pass, send TDLR a certificate of commercial general liability insurance to get your license. Licenses renew every year.
TDLR: apply for an ACR contractor license (opens in a new tab)
How to prepare
- Bring the code books for the 2024 editions. The exam switched from the 2021 codes on September 1, 2026; the bulletin's itemized list still shows 2021, but the 2024 notice on its cover is what applies.
- Air distribution (duct design) is the biggest topic. Know how to use Manual D friction rate, total effective length and the ADI duct calculator, and the IMC duct construction and installation rules.
- Tab the Texas ACR law (Occupations Code 1302) and rules (16 TAC 75). They're 6 easy points if you can find them fast.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2024 IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2024 International Mechanical Code (IMC)Essential
Equipment access, condensate, exhaust (including dryer ducts), duct construction and refrigeration.
ICC store (opens in a new tab)Read free (opens in a new tab)
2024 International Fuel Gas Code (IFGC)
Combustion air, venting and gas pipe sizing.
ICC store (opens in a new tab)Read free (opens in a new tab)
ACCA Manual J (8th), Manual D (3rd), Manual S (2nd) and the ACCA duct slide rule
Load calculations, duct design and equipment selection.
Modern Refrigeration and Air Conditioning, 22nd Edition (Goodheart-Willcox)
Refrigeration cycle, troubleshooting, piping and controls.
Texas ACR law and rules: Occupations Code Chapter 1302 and 16 TAC Chapter 75
The source of the Texas Laws and Rules questions. Print them, tab them and bring them.
Official reference list (as published by the testing agency)
- 2024 International Mechanical Code (IMC) or 2024 Uniform Mechanical Code (UMC)
- 2024 International Fuel Gas Code (IFGC)
- ACCA Manual J (8th Ed.), Manual D and Manual S
- Modern Refrigeration and Air Conditioning, 22nd Edition (Goodheart-Willcox)
- Texas Occupations Code Chapter 1302 and 16 Texas Administrative Code Chapter 75
- OSHA 29 CFR Part 1904 (injury recordkeeping)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Air Distribution | 18 | |
| Equipment Requirements and Design | 14 | |
| Service | 12 | |
| Testing | 12 | |
| HVAC Systems | 11 | |
| Basic Refrigeration Components | 6 | |
| Combustion Air | 6 | |
| Controls | 6 | |
| Piping | 6 | |
| Refrigeration Principles | 6 | |
| Safety | 6 | |
| Texas Laws and Rules | 6 | |
| Ventilation | 6 | |
| Venting | 5 |
The outline totals 120; the other items on the 125-question exam are unscored or unassigned.
Exam day details
- Administered by PSI Services for the Texas Department of Licensing and Regulation (TDLR).
- Fee: $74 for Class A or $60 for Class B (PSI), plus TDLR's $115 license application fee.
- Class A (any size equipment): 120 scored items plus 5 unscored, 240 minutes, $74. Class B (cooling up to 25 tons, heating up to 1.5 million Btu/h): 100 scored items plus 5 unscored, 180 minutes, $60. The topic outline is the same; Class B has about 5/6 as many questions per topic. Our simulation follows Class A.
- Since September 1, 2026 the code questions are based on the 2024 IMC, UMC and IFGC.
- Open book: bound or binder-held references, highlighted and noted beforehand, permanent tabs only, no marking during the exam. A silent non-programmable calculator is allowed.
- There's no separate business and law exam; Texas law and rules are 6 questions (5 on Class B) inside this exam.
- In TDLR's fiscal year 2025, 36% of Environmental Air Class A attempts and 26% of Class B attempts passed.
- Offered in English and Spanish. Retakes are unlimited during your one-year eligibility period.
Frequently asked questions
What's the difference between the Texas ACR Class A and Class B exams?
Class A licenses any size equipment; Class B is limited to cooling systems of 25 tons or less and heating systems of 1.5 million Btu/h or less. Both Environmental Air exams use the same topic outline: Class A has 120 scored questions in 240 minutes and Class B has 100 in 180 minutes.
Is the Texas ACR exam open book?
Yes. You can bring the IMC or UMC, the IFGC, ACCA Manuals J, D and S, Modern Refrigeration and Air Conditioning, and the Texas ACR law and rules. Books can be highlighted and tabbed with permanent tabs beforehand.
What's the pass rate for the Texas ACR contractor exam?
In fiscal year 2025, about 36% of Environmental Air Class A attempts and 26% of Class B attempts passed (TDLR statistics). Air distribution (duct design) is the largest topic.
Free questions with answers
Show all 10 free questions and answers
Under the 2024 IMC, what is the minimum number of sheet metal screws or rivets required to mechanically fasten a joint in round metallic duct?
Answer: Three
IMC Section 603.4.1 requires round metallic ducts to be mechanically fastened with at least three sheet metal screws or rivets, spaced equally around the joint. If part of the joint can't be reached, the three fasteners still go on the exposed portion, spaced so the joint can't hinge. Two fasteners would leave exactly the hinge effect the rule is meant to prevent.
Reference: 2024 International Mechanical Code, Section 603.4.1
A 12-inch round supply duct carries air at an average velocity of 800 feet per minute. What is the approximate airflow?
Answer: 628 cfm
Airflow (cfm) = velocity (fpm) × area (sq ft). A 12-inch duct has a radius of 0.5 ft, so area = π × 0.5² = 0.785 sq ft, and 800 × 0.785 = 628 cfm. Treating the duct as 1 square foot (12 × 12 in.) gives 800 cfm. Using π × r without squaring gives 1,257 cfm. Using the 1-ft diameter as the radius gives 2,513 cfm.
Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 28: Air Movement and Measurement
An air handler moves 1,200 cfm of standard air, and the dry-bulb temperature drops 20°F across the coil. What is the sensible cooling capacity being delivered?
Answer: 25,920 Btu/h
Sensible heat for standard air is Q = 1.08 × cfm × ΔT = 1.08 × 1,200 × 20 = 25,920 Btu/h. The 16,320 answer uses the latent factor (0.68), which goes with a change in grains of moisture, not temperature. The 108,000 answer uses the total-heat factor (4.5), which goes with an enthalpy difference in Btu/lb. The 24,000 answer leaves out the 1.08 constant.
Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 32: Heating and Cooling Loads
On a split air conditioner, the suction line temperature at the service valve is 52°F. The suction pressure converts on the P/T chart to a saturation temperature of 40°F. What is the superheat?
Answer: 12°F
Superheat = actual suction line temperature - saturated suction (evaporating) temperature = 52 - 40 = 12°F. Superheat is how much the vapor has been heated above its boiling point after all the liquid has boiled off. The 92°F answer adds the two temperatures, and 40°F and 52°F are just the two inputs. Compare the result with the manufacturer's target superheat for the indoor wet-bulb and outdoor dry-bulb conditions.
Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 12: Working with Refrigerants
On a TXV-equipped R-410A system, the liquid line pressure converts to a saturated condensing temperature of 110°F. The liquid line temperature is 98°F, and outdoor air is 95°F. What is the subcooling?
Answer: 12°F
Subcooling = saturated condensing temperature - actual liquid line temperature = 110 - 98 = 12°F. Subcooling shows how far the liquid has been cooled below its condensing temperature. The 15°F answer (110 - 95) is the condenser approach or split over ambient, not subcooling. The 3°F answer compares the liquid line to outdoor air. On TXV systems, subcooling is the main charging check.
Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 12: Working with Refrigerants
A gas furnace has an input of 100,000 Btu/h and an output of 80,000 Btu/h. The measured temperature rise is 50°F. What is the approximate airflow through the furnace?
Answer: 1,481 cfm
Airflow from temperature rise: cfm = output Btu/h ÷ (1.08 × ΔT) = 80,000 ÷ (1.08 × 50) = 80,000 ÷ 54 = 1,481 cfm. Use the output (heat actually delivered to the air), not the input. Using the input gives 1,852 cfm. Leaving out the 1.08 factor gives 1,600 or 2,000 cfm.
Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 33: Gas-Fired Heating Systems
A 100,000 Btu/h furnace and a 40,000 Btu/h water heater, both natural-draft, share a 20 ft × 15 ft × 8 ft mechanical room. Using the 2024 IFGC standard method, how much indoor volume is required?
Answer: 7,000 cubic feet
Total input = 100,000 + 40,000 = 140,000 Btu/h. Required volume = 140 × 50 cu ft = 7,000 cu ft (IFGC Section 304.5.1). The room is only 20 × 15 × 8 = 2,400 cu ft, so it doesn't qualify on its own. Combustion air must come from adjoining spaces (Section 304.5.3) or from outdoors (Section 304.6). The 5,000 answer counts only the furnace, and 14,000 uses 100 cu ft per 1,000 Btu/h.
Reference: 2024 International Fuel Gas Code, Sections 304.5 and 304.5.1
Under Texas Occupations Code Chapter 1302, what is the largest cooling capacity a Class B air conditioning and refrigeration contractor may work on?
Answer: 25 tons
Section 1302.253(c) limits a Class B license to systems, products or equipment of no more than 25 tons cooling capacity or 1.5 million Btu/h output heating capacity. A Class A license has no size limit (1302.253(b)). Section 1302.002(9) defines cooling capacity as nominal compressor tonnage based on 40°F suction and 105°F condensing temperatures.
Reference: Texas Occupations Code Chapter 1302, §1302.253
A new 2,000-square-foot single-family home has 3 bedrooms. Under 2024 IMC Equation 4-9, what is the minimum continuous outdoor airflow for whole-house mechanical ventilation?
Answer: 90 cfm
IMC Section 403.3.2.1, Equation 4-9: Q = 0.03 × floor area + 7.5 × (bedrooms + 1) = 0.03 × 2,000 + 7.5 × (3 + 1) = 60 + 30 = 90 cfm. Leaving out the "+1" gives 82.5 cfm. Using an older 0.01-cfm-per-square-foot factor gives 50 cfm. Using the 0.06 cfm per square foot rate for common areas gives 150 cfm.
Reference: 2024 International Mechanical Code, Section 403.3.2.1, Equation 4-9
Under the 2024 IMC specified-length method, a domestic dryer exhaust duct has two 6-inch radius smooth 90-degree elbows and one 6-inch radius smooth 45-degree elbow, and the dryer manufacturer's instructions give no length. What is the maximum developed length of straight duct allowed?
Answer: 30.5 feet
IMC Section 504.9.4.1 sets a 35-foot maximum from the transition duct connection to the outlet terminal, reduced by the fitting equivalent lengths in Table 504.9.4.1. A 6-inch radius smooth 90° elbow counts as 1 ft 9 in (1.75 ft), and a 6-inch radius smooth 45° elbow counts as 1 ft. So 35 - (2 × 1.75) - 1 = 30.5 feet. The 22.5-foot answer uses the 4-inch mitered values (5 ft and 2.5 ft). The UMC has a different dryer-duct length rule, so this question is specific to the IMC.
Reference: 2024 International Mechanical Code, Section 504.9.4.1 and Table 504.9.4.1
Sources
- PSI: TDLR Air Conditioning and Refrigeration Candidate Information Bulletin (opens in a new tab)
- TDLR: ACR exam information (opens in a new tab)
- TDLR: Apply for an ACR contractor license (opens in a new tab)
- TDLR: FY2025 ACR exam statistics (opens in a new tab)
Questions last verified October 7, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.