Requirements at a glance
| Agency | City of Philadelphia Department of Licenses and Inspections; exam by ICC, delivered by Pearson VUE |
|---|---|
| Exam | ICC 249 Master Plumber: 100 questions, 4 hours, CLOSED book |
| Experience | 1 year as a registered Philadelphia journeyman plumber |
| Books allowed | None. The exam is closed book |
| Fees | $115 to Pearson VUE; Philadelphia Master Plumber license $303, renews $253 a year (L&I pages, check current fees) |
Plumbers applying for a Philadelphia Master Plumber license, which requires 1 year as a registered Philadelphia journeyman plumber.
Official links
How to get licensed, step by step
Check you qualify
You need to be a registered Philadelphia journeyman plumber with at least 1 year in that role.
City of Philadelphia: Licenses and Inspections (opens in a new tab)
Schedule exam 249 with Pearson VUE
Book through Pearson VUE ($115). If you fail, wait 10 days to retake.
Schedule with Pearson VUE (ICC exams) (opens in a new tab)ICC: Philadelphia Contractor/Trades Examination Information Bulletin (opens in a new tab)
Pass and apply to L&I
Send your results with your application and fee to Licenses and Inspections.
City of Philadelphia: Licenses and Inspections (opens in a new tab)
How to prepare
- Closed book: you can't look anything up, so memorize pipe sizing tables, fixture unit values, trap and vent distances and test requirements.
- Plan reading and analysis is 30% of the exam. Practice sizing drains, vents and water piping from a plan.
- The bulletin lists the Philadelphia Plumbing Code 2018. Philadelphia has adopted the 2021 I-Codes, so check the current bulletin before you test.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
Philadelphia Plumbing Code 2018 (2018 IPC with Philadelphia amendments)Essential
NOT allowed in the exam room (closed book). Study it, because the whole exam comes from it.
Official reference list (as published by the testing agency)
- Philadelphia Plumbing Code 2018 (the exam is closed book; no references are allowed in the room)
What's on the exam
Official content outline from International Code Council (ICC), delivered by Pearson VUE (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Plumbing Fixtures and Terminology | 6 | |
| Plumbing Fundamentals and Administrative | 8 | |
| Traps, Interceptors, and Cleanouts | 10 | |
| Special Requirements | 6 | |
| Drainage Requirements | 15 | |
| Venting Requirements | 15 | |
| Water Distribution | 10 | |
| Plan Reading and Analysis | 30 |
Exam day details
- Administered by International Code Council (ICC), delivered by Pearson VUE for the City of Philadelphia Department of Licenses and Inspections.
- Fee: $115 to Pearson VUE. City of Philadelphia license fees are separate.
- 100 questions in 4 hours. This is a CLOSED-book exam, so you must know the code without looking it up.
- The bulletin lists the Philadelphia Plumbing Code 2018 (the 2018 IPC with Philadelphia amendments). Philadelphia adopted the 2021 I-Codes in 2025, but the March 2026 exam bulletin still names the 2018 code. TODO(verify): check the current ICC bulletin for a change before your test date.
- Plan reading and analysis is 30% of the exam, with drainage and venting another 30%.
- ICC writes the exam and Pearson VUE delivers it. Every question is four-option multiple choice with one correct answer.
- If you fail, you must wait 10 days before you retake the exam.
- The ICC Philadelphia bulletin does not print a passing score. TODO(verify): confirm the passing score with ICC before you sit.
- Philadelphia's published exam results are valid for 12 months for applying, unless the code edition has changed.
Frequently asked questions
Is the Philadelphia master plumber exam open book?
No. ICC lists exams 249 and 250 as closed book.
Which code does it use?
The Philadelphia Plumbing Code 2018, per the ICC bulletin dated March 15, 2026.
What's on the exam?
Plan reading and analysis 30%, drainage 15%, venting 15%, traps, interceptors and cleanouts 10%, water distribution 10%, plumbing fundamentals and administrative 8%, plumbing fixtures and terminology 6% and special requirements 6%.
Free questions with answers
Show all 10 free questions and answers
A school toilet room requires 12 water closets. Using the maximum substitution allowed in assembly and educational occupancies, how many urinals may replace water closets?
Answer: 8 urinals
Section 424.2 limits urinal substitution to 67 percent of the required water closets in assembly and educational occupancies: 12 x 0.67 = 8.04, so 8 whole urinals. Six comes from applying the 50 percent limit that governs other occupancies.
Reference: Philadelphia Plumbing Code 2018, 424.2
A pipe passes through a foundation wall. How large must the sleeve built into the wall be compared with the pipe?
Answer: Two pipe sizes larger than the pipe
Section 305.3 requires a relieving arch or a pipe sleeve built into the foundation wall, with the sleeve two pipe sizes greater than the pipe passing through. One size would not give the clearance the section intends.
Reference: Philadelphia Plumbing Code 2018, 305.3
On which buildings does Philadelphia require a relief vent on the house drain ahead of the main house trap, and how large is it on an 8-inch house drain?
Answer: Buildings 75 feet or higher; 4 inches
Sections P-1002.6.3 and P-901.2.2 require the relief vent for buildings 75 feet or higher, connected to the nearest vent line. It is at least 4 inches on drains of 8 inches or less and at least 5 inches on drains of 10 inches and over.
Reference: Philadelphia Plumbing Code 2018, P-1002.6.3
A pump or ejector receives the discharge of water closets. What size of spherical solids must it be able to handle?
Answer: Up to and including 2 inches
Section 712.4.2 requires pumps and ejectors that receive water closet discharge to pass spherical solids up to 2 inches. Other pumps and ejectors need only pass 1/2-inch solids.
Reference: Philadelphia Plumbing Code 2018, 712.4.2
What is the minimum slope for a horizontal drain 4 inches in diameter, other than piping draining to a grease interceptor?
Answer: 1/8 inch per foot
Table P-704.1 sets 1/4 inch per foot for pipes 3 inches and smaller, 1/8 inch per foot for 4 to 6 inches, and 1/16 inch per foot for 8 inches and larger.
Reference: Philadelphia Plumbing Code 2018, Table P-704.1
What is the minimum slope for a 3-inch horizontal fixture branch?
Answer: 1/4 inch per foot
Pipes 3 inches or smaller require 1/4 inch per foot under Table P-704.1; the 1/8 inch per foot slope starts at 4-inch pipe.
Reference: Philadelphia Plumbing Code 2018, Table P-704.1
Under the Philadelphia amendments, how far must an open vent extend above a roof that is not used for any special purpose?
Answer: Not less than 24 inches
Philadelphia Section P-903.1 requires open vents through a roof to terminate at least 24 inches above the roof. The base IPC distance is shorter, so the Philadelphia value governs.
Reference: Philadelphia Plumbing Code 2018, P-903.1
At what static pressure must a pressure-reducing valve be installed in a building water supply?
Answer: Where static pressure exceeds 80 psi
Section 604.8 requires an ASSE 1003 pressure-reducing valve with strainer where static pressure exceeds 80 psi, limiting building pressure to 80 psi or less. Sill cock service lines are excepted.
Reference: Philadelphia Plumbing Code 2018, 604.8
On a floor plan at 1/4 inch = 1 foot, two wall-hung lavatories with no partition between them must meet the minimum center-to-center spacing. What is that spacing on the drawing?
Answer: 5/8 inch
Section 405.3.1 requires 30 inches (2.5 feet) between adjacent fixtures. At 1/4 inch per foot, 2.5 x 1/4 = 0.625 inch, or 5/8 inch. Three-quarters of an inch would be 36 inches.
Reference: Philadelphia Plumbing Code 2018, 405.3.1
On a plan the upstream invert of a 4-inch building drain is elevation 100.00 feet. The drain runs 48 feet at the minimum code slope. What is the downstream invert elevation?
Answer: 99.50 feet
At 1/8 inch per foot, 48 ft x 1/8 = 6 inches = 0.50 foot of fall, so 100.00 - 0.50 = 99.50. Using 1/4 inch per foot gives 1.00 foot (99.00), which is the slope for pipes 3 inches and smaller.
Reference: Philadelphia Plumbing Code 2018, Table P-704.1
Sources
- ICC: Philadelphia Contractor/Trades Examination Information Bulletin (3/15/2026) (opens in a new tab)
- Pearson VUE: ICC exams (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.