Requirements at a glance
| Agency | North Dakota State Electrical Board (NDSEB); board-run exam |
|---|---|
| Experience | 8,000 hours (at least 3 years) as a registered apprentice, with apprentice training completed |
| Exam | 1 hour closed book plus 3.5 hours open book; 70% to pass |
| Books allowed | Code books are supplied by the Board (NEC and the North Dakota Laws, Rules, Wiring and Conveyance Standards) |
| Fees | Application fee $40 (NDAC 24.1-03-01-01); exam fee not published; license fee set by the Board |
Electricians applying to the State Electrical Board for a journeyman license after 8,000 hours (at least 3 years) as a registered apprentice, with apprentice training completed.
Official links
How to get licensed, step by step
Apply to the Board
Send the Board your license application and fee. If approved, you receive an invite listing the exam dates then available.
North Dakota State Electrical Board (opens in a new tab)NDSEB: exam dates and information (opens in a new tab)
Pick a date and test
You must test within 6 months of the invite. A cancellation or no-show means a new application and fee.
Pass both parts
A 1-hour closed-book part and a 3.5-hour open-book part; the passing grade is 70%. The Board gives no exam reviews.
If you fail
Send a re-exam application and fee. Waits depend on your score: 60 to 69 none, 50 to 59 three months, 0 to 49 six months.
How to prepare
- Exams given in December 2026 and later are based on the 2026 NEC and the 2026 ND Laws, Rules, Wiring and Conveyance Standards. Our questions follow the 2026 NEC and cite the 2026 article number where one moved (for example Article 120, formerly 220).
- The Board publishes no outline or question counts, so our topic split is an estimate. Expect fundamental electricity, the NEC and the North Dakota wiring standards.
- The Board supplies the code books, calculators and pencils, so practice finding answers fast in the 2026 NEC and tab the North Dakota rules you know you will need.
- Wiring methods and materials and branch circuits and conductors are the biggest areas in our split: drill conductor ampacity, box fill, raceway fill and overcurrent protection.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2026 EditionEssential
The Board supplies code books in the exam room. Exams given from December 2026 are based on the 2026 NEC and the 2026 ND Laws, Rules, Wiring and Conveyance Standards.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), the edition in force at your exam date. Exams given in December 2026 and later are based on the 2026 NEC and the 2026 ND Laws, Rules, Wiring and Conveyance Standards.
- North Dakota Laws, Rules, Wiring and Conveyance Standards (NDAC 24.1)
- The Board provides code books, calculators and pencils; you do not bring your own.
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| General Knowledge | 6 | |
| Services and Service Equipment | 8 | |
| Feeders | 5 | |
| Branch Circuits and Conductors | 16 | |
| Wiring Methods and Materials | 18 | |
| Equipment and Devices | 10 | |
| Motors and Generators | 10 | |
| Special Occupancies, Equipment and Conditions | 12 | |
| North Dakota Laws, Rules and Wiring Standards | 15 |
Exam day details
- Administered by the North Dakota State Electrical Board (board-run exam).
- Fee: Exam fee not published. Application fees: $50 master and Class B, $40 journeyman (NDAC 24.1-03-01-01). License fees are separate.
- Closed book 1 hour plus open book 3.5 hours; 70% to pass. Question counts are not published; our practice exam uses 100 questions.
- The exam has a closed-book part (1 hour) and an open-book part (3.5 hours). The Board supplies the code books, calculators and pencils.
- Apply to the Board first. If approved you get an invite listing the available dates, and you must test within 6 months of the invite. A cancellation or no-show means a new application and fee.
- The passing grade is 70%. After a failed exam, send a re-exam application and fee. Waits depend on your score: 60 to 69 none, 50 to 59 three months, 0 to 49 six months. The Board gives no exam reviews.
- Our questions follow the 2026 NEC. Where an article was renumbered, we cite the 2026 number (for example Article 120, formerly 220). We could not read the 2026 NEC text itself, so questions use only rules confirmed unchanged from 2023 or confirmed in published change lists.
Note: The State Electrical Board does not publish question counts, a content outline or topic weights, so the question count and topic split here are our estimates. Exams from December 2026 are based on the 2026 NEC; we could not read the NFPA 2026 text, so confirm article numbers in the code book the Board provides.
Frequently asked questions
What's on the North Dakota journeyman electrician exam?
The Board says it covers fundamental electricity, the North Dakota Laws, Rules and Wiring Standards and the NEC. It publishes no outline, so our topic split is an estimate: wiring methods and materials, branch circuits and conductors and North Dakota rules carry the most weight.
Which NEC edition do the exams use?
Exams given in December 2026 and later use the 2026 NEC and the 2026 ND Laws, Rules, Wiring and Conveyance Standards. The 2023 NEC applied from July 1, 2024.
What if I fail?
Send a re-exam application and fee. The wait depends on your score: none at 60 to 69, 3 months at 50 to 59, 6 months at 0 to 49.
Free questions with answers
Show all 10 free questions and answers
A balanced three-phase, 208-volt load is rated 36 kVA. What is the line current, rounded to the nearest ampere?
Answer: 100 amperes
For three-phase loads I = VA / (E x 1.732) = 36,000 / (208 x 1.732) = 99.9, or 100 A. Leaving out 1.732 gives 173 A (36,000 / 208); using 240 V with the single-phase formula gives 150 A; dividing the 173 A figure by 3 gives 58 A. None of those is the three-phase formula.
Reference: NFPA 70, National Electrical Code (2026), General electrical theory: three-phase power
A commercial building's service will use a switchboard with a separate disconnecting means for each of several tenants. What is the maximum number of switches or circuit breakers that may serve as the disconnecting means for one service?
Answer: Six
Section 230.71 allows two to six service disconnecting means for each service, grouped together. A seventh disconnect would mean a separate service as allowed by 230.2, not a larger group on this service. Power monitoring, SPD and similar devices built into the equipment do not count toward the six.
Reference: NFPA 70, National Electrical Code (2026), 230.71
A feeder is protected by a 200-ampere overcurrent device and its copper grounded (neutral) conductor carries very little current. Using 215.2(B) and Table 250.122, what is the smallest copper size allowed for that grounded conductor?
Answer: 6 AWG
Section 215.2(B) says the feeder grounded conductor may not be smaller than the equipment grounding conductor required by 250.122. Table 250.122 gives 6 AWG copper for a 200 A device. 3 AWG would be the ungrounded size for about 100 A, not the minimum neutral. 10 AWG and 8 AWG are the sizes for 60 A and 100 A or less.
Reference: NFPA 70, National Electrical Code (2026), 215.2(B) and Table 250.122
A 20-ampere branch circuit supplies several receptacles in a workshop. What ampere rating may the receptacles have?
Answer: 15 or 20 amperes
Section 210.21(B)(2) and Table 210.21(B)(3) allow 15 A or 20 A receptacles on a 20 A circuit supplying two or more receptacles. A single receptacle on an individual circuit must be rated not less than the circuit (210.21(B)(1)), but this is a multiple-receptacle circuit.
Reference: NFPA 70, National Electrical Code (2026), 210.21(B)(2); Table 210.21(B)(3)
In a dwelling bathroom, where must the required receptacle outlet be located in relation to each sink?
Answer: Within 3 ft of the outside edge of the sink
Section 210.52(D) requires at least one receptacle within 3 ft of the outside edge of each sink, on an adjacent wall or partition, on the countertop, or on the side or face of the sink cabinet, no more than 12 in. below the top of the sink or countertop. It is measured from the sink edge, not its center or the door.
Reference: NFPA 70, National Electrical Code (2026), 210.52(D)
A 120-volt, 20-ampere residential branch circuit with GFCI protection is wired with Type UF cable buried directly in the ground. Using Table 300.5(A), what is the minimum cover?
Answer: 12 inches
Column 4 of Table 300.5(A) applies to residential branch circuits rated 120 volts or less with GFCI protection and a maximum 20 A overcurrent device: 12 in. for the usual locations. 24 in. is Column 1, the general direct-burial cable depth where those conditions are not met; 18 in. is the EMT or nonmetallic raceway depth in Column 3; 6 in. is rigid metal conduit in Column 2.
Reference: NFPA 70, National Electrical Code (2026), Table 300.5(A), Column 4
For motor disconnecting purposes, a controller disconnecting means is 'in sight from' the motor when it is visible and within what distance?
Answer: 50 feet
Article 100 defines 'in sight from' as visible and not more than 15 m (50 ft) distant. Section 430.102 requires a disconnecting means within sight of the controller and, unless an exception applies, within sight of the motor and driven machinery. A lockable disconnect farther away may serve where permitted by the exceptions.
Reference: NFPA 70, National Electrical Code (2026), Article 100, Definitions; 430.102
A 125-volt, 15-ampere nonlocking receptacle is installed under a roofed open porch where it is protected from beating rain. What does 406.9(A) require?
Answer: A listed weather-resistant type in an enclosure that is weatherproof when the cover is closed
Section 406.9(A) treats this as a damp location: the enclosure must be weatherproof when the receptacle is covered (plug not inserted, cover closed), and all 125- and 250-volt nonlocking 15 and 20 A receptacles in damp or wet locations must be listed weather-resistant. The 'while plugged in' rule is the stricter wet-location rule in 406.9(B).
Reference: NFPA 70, National Electrical Code (2026), 406.9(A)
Which hazardous-location class covers areas where flammable gases or vapors, such as gasoline vapor, may be present in ignitable concentrations?
Answer: Class I
Section 500.5 groups locations by the material: Class I is flammable gases, flammable liquid-produced vapors and combustible liquid-produced vapors; Class II is combustible dust; Class III is ignitable fibers or flyings. There is no Class IV in the NEC classification system.
Reference: NFPA 70, National Electrical Code (2026), 500.5(B)
Under the North Dakota standards, what minimum distance must overhead conductors keep from a water well or a known site where a water well may be drilled?
Answer: 20 feet in all directions
NDAC 24.1-06-01-10(4) says overhead conductors may not cross over water wells or known well sites, and a minimum distance of twenty feet in all directions must be maintained.
Reference: NDAC Title 24.1, North Dakota Laws, Rules and Wiring Standards (2026), NDAC 24.1-06-01-10(4)
Sources
- North Dakota State Electrical Board: exam dates and information (opens in a new tab)
- North Dakota State Electrical Board (qualifications, laws and rules) (opens in a new tab)
Questions last verified November 7, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.