North Dakota licensing exam

North Dakota Class B Electrician Exam: Practice Test & Licensing Guide

The North Dakota State Electrical Board Class B exam for farmstead and residential wiring: NEC and the North Dakota wiring standards, a 1-hour closed-book part and a 3.5-hour open-book part. 70% to pass.

Questions
Not published by North Dakota
Time limit
4.5 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge

A 20-ohm resistor and a 5-ohm resistor are connected in parallel across a supply. What is the total resistance of the pair?

Requirements at a glance

AgencyNorth Dakota State Electrical Board (NDSEB); board-run exam
Experience18 months and 3,000 hours of farmstead or residential wiring in one- and two-family dwellings (commercial hours do not count)
Exam1 hour closed book plus 3.5 hours open book; 70% to pass
Books allowedCode books are supplied by the Board (NEC and the North Dakota Laws, Rules, Wiring and Conveyance Standards)
FeesApplication fee $50 (NDAC 24.1-03-01-01); exam fee not published; license fee set by the Board

Electricians applying to the State Electrical Board for a Class B license after 18 months and 3,000 hours of farmstead or residential wiring in one- and two-family dwellings. A Class B license is contracting status only and covers farmstead and residential work in a city of 2,500 people or fewer.

How to get licensed, step by step

  1. Apply to the Board

    Send the Board your license application and fee. If approved, you receive an invite listing the exam dates then available.

    North Dakota State Electrical Board (opens in a new tab)NDSEB: exam dates and information (opens in a new tab)

  2. Pick a date and test

    You must test within 6 months of the invite. A cancellation or no-show means a new application and fee.

    NDSEB: exam dates and information (opens in a new tab)

  3. Pass both parts

    A 1-hour closed-book part and a 3.5-hour open-book part; the passing grade is 70%. The Board gives no exam reviews.

    NDSEB: exam dates and information (opens in a new tab)

  4. If you fail

    Send a re-exam application and fee. Waits depend on your score: 60 to 69 none, 50 to 59 three months, 0 to 49 six months.

    NDSEB: exam dates and information (opens in a new tab)

How to prepare

  • Exams given in December 2026 and later are based on the 2026 NEC and the 2026 ND Laws, Rules, Wiring and Conveyance Standards. Our questions follow the 2026 NEC and cite the 2026 article number where one moved (for example Article 120, formerly 220).
  • The Board publishes no outline or question counts, so our topic split is an estimate. Expect fundamental electricity, the NEC and the North Dakota wiring standards.
  • The Board supplies the code books, calculators and pencils, so practice finding answers fast in the 2026 NEC and tab the North Dakota rules you know you will need.
  • A Class B license is contracting status only and limited to farmstead and residential work in a city of 2,500 or fewer. Drill dwelling branch circuits, receptacle and GFCI rules and grounding.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC), the edition in force at your exam date. Exams given in December 2026 and later are based on the 2026 NEC and the 2026 ND Laws, Rules, Wiring and Conveyance Standards.
  • North Dakota Laws, Rules, Wiring and Conveyance Standards (NDAC 24.1)
  • The Board provides code books, calculators and pencils; you do not bring your own.

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
General Knowledge8
Services and Service Equipment12
Feeders6
Branch Circuits and Conductors18
Wiring Methods and Materials12
Equipment and Devices8
Special Occupancies, Equipment and Conditions6
North Dakota Laws, Rules and Wiring Standards10

Exam day details

  • Administered by the North Dakota State Electrical Board (board-run exam).
  • Fee: Exam fee not published. Application fees: $50 master and Class B, $40 journeyman (NDAC 24.1-03-01-01). License fees are separate.
  • Closed book 1 hour plus open book 3.5 hours; 70% to pass. Question counts are not published; our practice exam uses 80 questions.
  • The exam has a closed-book part (1 hour) and an open-book part (3.5 hours). The Board supplies the code books, calculators and pencils.
  • Apply to the Board first. If approved you get an invite listing the available dates, and you must test within 6 months of the invite. A cancellation or no-show means a new application and fee.
  • The passing grade is 70%. After a failed exam, send a re-exam application and fee. Waits depend on your score: 60 to 69 none, 50 to 59 three months, 0 to 49 six months. The Board gives no exam reviews.
  • Our questions follow the 2026 NEC. Where an article was renumbered, we cite the 2026 number (for example Article 120, formerly 220). We could not read the 2026 NEC text itself, so questions use only rules confirmed unchanged from 2023 or confirmed in published change lists.

Note: The State Electrical Board does not publish question counts, a content outline or topic weights, so the question count and topic split here are our estimates. Exams from December 2026 are based on the 2026 NEC; we could not read the NFPA 2026 text, so confirm article numbers in the code book the Board provides.

Frequently asked questions

What's on the North Dakota Class B electrician exam?

The Board says it covers fundamental electricity, the North Dakota Laws, Rules and Wiring Standards and the NEC. It publishes no outline, so our split is an estimate weighted toward residential branch circuits, services and North Dakota rules.

What can a Class B electrician do?

Farmstead and residential wiring in a city with a population of 2,500 or fewer, in contracting status only. Commercial hours do not count toward the license.

Which NEC edition do the exams use?

Exams given in December 2026 and later use the 2026 NEC and the 2026 ND Laws, Rules, Wiring and Conveyance Standards.

Free questions with answers

Show all 10 free questions and answers
  1. A 20-ohm resistor and a 5-ohm resistor are connected in parallel across a supply. What is the total resistance of the pair?

    Answer: 4 ohms

    For two resistors in parallel, R = (R1 x R2) / (R1 + R2) = (20 x 5) / 25 = 4 ohms. The total is always smaller than the smallest branch. Adding gives 25 (the series answer), averaging gives 12.5, and the product alone is 100.

    Reference: Basic electrical theory: Ohm's law and power relationships, Parallel resistance: R = (R1 x R2) / (R1 + R2)

  2. Overhead service conductors (120/240 volts) cross a farm lane used by trucks and combines to reach a cultivated field. What is the minimum clearance above the lane?

    Answer: 18 feet

    Section 230.24(B)(4) requires 18 ft over public streets, alleys, roads, parking areas subject to truck traffic, driveways on other than residential property and other land traversed by vehicles such as cultivated, grazing, forest and orchard land. The 12 ft value is for residential property and driveways only.

    Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), 230.24(B)(4)

  3. Open individual service conductors are run on a house wall beside a porch. What is the minimum clearance required from the porch?

    Answer: 3 feet

    Section 230.9(A) requires open service conductors to be at least 3 ft from windows designed to be opened, doors, porches, balconies, ladders, stairs, fire escapes and similar locations. The exception allows less only above the top level of a window.

    Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), 230.9(A)

  4. A feeder supplies 120 amperes of continuous load and 60 amperes of noncontinuous load, and its overcurrent device is not rated for 100 percent continuous operation. What is the smallest standard overcurrent device rating that satisfies 215.3?

    Answer: 225 amperes

    Section 215.3 requires a rating of at least the noncontinuous load plus 125 percent of the continuous load: 60 + (120 x 1.25) = 60 + 150 = 210 A. The next standard size in 240.6(A) at or above 210 A is 225 A. 200 A is too small, 250 A is larger than needed, and 210 A is not a standard rating.

    Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), 215.3 and 240.6(A)

  5. A homeowner wants the 20-ampere laundry receptacle circuit to also supply a hall light on the second floor. Does the NEC allow that?

    Answer: No, the laundry circuit may not supply any other outlets

    Section 210.11(C)(2) requires at least one additional 20-ampere circuit for the laundry receptacle outlet(s) required by 210.52(F), and says it shall have no other outlets. A light is an outlet, so it cannot share the circuit no matter the wire size or floor.

    Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), 210.11(C)(2)

  6. Type NM-B cable is stapled along the side of floor joists in an unfinished basement. What is the maximum spacing between cable supports?

    Answer: 4 1/2 feet

    Section 334.30 requires NM cable to be secured at intervals not exceeding 4 1/2 ft and within 12 in. of every box, cabinet or fitting. The 3 ft and 6 ft values belong to other wiring methods and 2 ft is not a requirement for NM.

    Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), 334.30

  7. What is the maximum spacing between supports for 1 1/2 inch trade size rigid PVC conduit run horizontally on a wall?

    Answer: 5 feet

    Table 352.30(B) allows 3 ft for 1/2 through 1 in., 5 ft for 1 1/4 through 2 in., 6 ft for 2 1/2 through 3 in., 7 ft for 3 1/2 through 5 in. and 8 ft for 6 in. trade size. A 1 1/2 in. conduit falls in the 5 ft group. 10 ft is the EMT figure.

    Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), 352.30(B), Table 352.30(B)

  8. An electrician mounts a 42-circuit panelboard on a basement wall of a house. With the top breaker handle in its highest position, the center of its grip may be no higher than what height above the floor?

    Answer: 6 feet 7 inches

    Section 240.24(A) requires the center of the grip of the operating handle, when in its highest position, to be not more than 2.0 m (6 ft 7 in.) above the floor or working platform. A panel mounted higher needs a working platform.

    Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), 240.24(A)

  9. A ceiling-suspended paddle fan will hang over an outdoor residential pool deck, within 5 feet horizontally of the inside wall of the pool. What is the minimum height of the fan above the maximum water level for a new installation?

    Answer: 12 feet

    Section 680.22(B)(1) requires luminaires, lighting outlets and ceiling-suspended paddle fans installed over the pool, or within 5 ft horizontally of its inside walls, to be at least 12 ft above the maximum water level, unless the specific exceptions are met. The 14 1/2 ft value is the diving-platform clearance in Table 680.9(A), and 10 ft is the figure for communications cables.

    Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), 680.22(B)(1)

  10. A contractor plans to run 8 AWG aluminum conductors for a 40-ampere residential branch circuit. What do the North Dakota wiring standards say about this?

    Answer: Not allowed, since aluminum smaller than 6 AWG is limited to Class 2 and Class 3 circuits

    NDAC 24.1-06-01-10(6) says aluminum or copper-clad aluminum conductors smaller than 6 AWG must be used only for Class 2 and Class 3 circuits. Terminal markings and a larger neutral do not remove the limit, but aluminum of 6 AWG and larger is not prohibited.

    Reference: NDAC Title 24.1, North Dakota Laws, Rules and Wiring Standards (2026), NDAC 24.1-06-01-10(6)

Sources

Questions last verified November 7, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.