Requirements at a glance
| Agency | New Mexico Regulation and Licensing Department, Construction Industries Division (CID); exams by PSI |
|---|---|
| Exam | Part 1 code: 50 questions, 145 minutes, open book. Part 2 theory: 50 questions, 120 minutes, closed book. 75% on each part, plus a practical exam |
| Books allowed | Part 1: NEC 2020 (or NEC Handbook) and New Mexico Electrical Code NMAC 14.10.4 (2020). Part 2 is closed book |
| Fees | Exam fees are paid to PSI (see the exam details above); license fees are separate. Check CID for current license fees. |
| Timing | Test within 6 months of becoming eligible. The exam fee and a passing score are each valid for 1 year. |
Electricians applying to Construction Industries Division for a journeyman (EE-98J) certificate. You also take a hands-on practical exam.
Official links
How to get licensed, step by step
Apply to CID through PSI
Candidates must be pre-approved before they can schedule. Submit your application and proof of qualifications through PSI's New Mexico construction page, or call PSI's approvals line at 877-663-9267.
PSI: apply and schedule New Mexico exams (opens in a new tab)New Mexico Construction Industries Division (CID) (opens in a new tab)
Get your references
Buy the exact code editions in PSI's bulletin. Books must be bound; highlighting, underlining and permanent tabs are allowed, but no loose notes or Post-its.
PSI Journeyman Candidate Information Bulletin (opens in a new tab)New Mexico Administrative Code (NMAC) titles (opens in a new tab)
Schedule and pay PSI
After approval, contact PSI to schedule a seat and pay. Test sites include Albuquerque, Farmington, Las Cruces, Roswell and Santa Fe.
PSI: apply and schedule New Mexico exams (opens in a new tab)
Pass and finish your license
You need 75%. You may not take the same exam more than twice in 30 days. Contractors also need the Business and Law exam; journeyman candidates take a hands-on practical exam too.
New Mexico Construction Industries Division (CID) (opens in a new tab)PSI Journeyman Candidate Information Bulletin (opens in a new tab)
How to prepare
- New Mexico tests the 2020 NEC. Do not study from a 2023 NEC; some rules changed between editions.
- Part 2 theory has no books in the room. Practice Ohm's law, voltage drop, motor and transformer basics and general knowledge (18 of its 50 questions).
- A hands-on practical exam (100 points, 120 minutes) is separate; our questions cover the written parts only.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2020 Edition (or the NEC Handbook)Essential
Bring your own, bound. New Mexico tests the 2020 edition, not 2023.
New Mexico Electrical Code (NMAC 14.10.4), 2020
State amendments; each exam has New Mexico State Code questions.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2020 edition, or the NEC Handbook
- New Mexico Electrical Code (NMAC 14.10.4), 2020
- National Electrical Safety Code (NESC), 2007 (Part 1)
- Part 2 theory is closed book; PSI lists American Electricians' Handbook (17th Edition) and Ugly's Electrical References (2008, 2011 or 2014) as references not allowed in the room
What's on the exam
Official content outline from PSI, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge and Electrical Installation Requirements | 22 | |
| Services, Feeders, and Branch Circuits | 12 | |
| Overcurrent Protection | 8 | |
| Grounding and Bonding | 11 | |
| Conductors and Cables | 8 | |
| Raceways and Boxes | 8 | |
| Hazardous Locations, Special Occupancies, and Special Equipment | 6 | |
| Lighting, Signs, and General-Use Equipment | 5 | |
| Motors, Transformers, and Generators | 5 | |
| New Mexico State Code | 4 | |
| Low Voltage, including Alarms | 11 |
The parts are timed and scored separately, and you must pass each one. Our simulations score each part the same way and give you the combined time (265 minutes).
Exam day details
- Administered by PSI, for the New Mexico Regulation and Licensing Department, Construction Industries Division (CID).
- Fee: $68.88 per part, paid to PSI. License and application fees are separate.
- Part 1 (code) is 50 questions in 145 minutes and open book. Part 2 (theory) is 50 questions in 120 minutes and closed book (PSI's exam sheet lists 135 minutes; the journeyman bulletin says 120). 75% to pass each part.
- Open book. Bring bound references; you may highlight, underline and index them with permanent tabs only. No loose papers, notes or Post-it tabs, and no writing in the books. This applies to Part 1 only.
- New Mexico tests the 2020 NEC plus NMAC 14.10.4, not the 2023 NEC.
- The journeyman license also needs a hands-on practical exam (100 points, 120 minutes, 75% to pass, $68.88). Our questions cover the written portion only.
- Get CID pre-approval through PSI first (PSI approvals line 877-663-9267). Once you are eligible you must test within 6 months, or reapply with the Division. Your exam fee is valid for 1 year and a passing score is valid for 1 year.
- You may not take the same exam more than twice in a 30-day period; after two fails you must wait 30 days from your first attempt.
Frequently asked questions
What's on the New Mexico journeyman electrician exam?
PSI's EE-98J outlines combined, 100 questions across Part 1 (code) and Part 2 (theory): General Knowledge and Electrical Installation Requirements 22; Services, Feeders, and Branch Circuits 12; Overcurrent Protection 8; Grounding and Bonding 11; Conductors and Cables 8; Raceways and Boxes 8; Hazardous Locations, Special Occupancies, and Special Equipment 6; Lighting, Signs, and General-Use Equipment 5; Motors, Transformers, and Generators 5; New Mexico State Code 4; Low Voltage, including Alarms 11.
Is the New Mexico journeyman electrician exam open book?
Part 1 (code) is open book with the 2020 NEC and NMAC 14.10.4. Part 2 (theory) is closed book. A separate hands-on practical exam is also required.
Who gives the New Mexico contractor and journeyman exams?
PSI, for the Construction Industries Division (CID) of the Regulation and Licensing Department. CID pre-approves your application, then you schedule with PSI at a New Mexico test center (Albuquerque, Farmington, Las Cruces, Roswell or Santa Fe) or an approved center elsewhere.
Free questions with answers
Show all 10 free questions and answers
Three resistors of 10, 15 and 25 ohms are connected in series across a 120-volt source. What is the circuit current?
Answer: 2.4 A
Series resistances add: 10 + 15 + 25 = 50 ohms. I = E / R = 120 / 50 = 2.4 A. Using only the 10-ohm resistor gives 12 A; 4.8 A comes from dividing by 25 ohms alone, and 0.42 A inverts the ratio.
Reference: General electrical theory: series circuits, Series circuit resistance
A dwelling has 2,400 square feet of floor area. What is the general lighting load before demand factors, using 3 VA per square foot?
Answer: 7,200 VA
NEC 2020 220.14(J) sets the dwelling general lighting load at 3 VA per square foot: 2,400 x 3 = 7,200 VA. (Table 220.12 covers non-dwelling occupancies only.) Under 220.11 the floor area is computed from the outside dimensions and excludes open porches, garages, and unused or unfinished spaces not adaptable for future use.
Reference: NFPA 70, National Electrical Code, 2020, 220.14(J); 220.11
A conductor with a calculated ampacity of 85 A supplies a non-receptacle load. What is the largest standard overcurrent device permitted to protect it under the next-size-up rule?
Answer: 90 A
Section 240.4(B) permits the next higher standard rating (240.6(A)) when the ampacity does not match a standard device, the circuit does not supply multioutlet receptacles for cord-and-plug loads, and the next size does not exceed 800 A. The next standard size above 85 A is 90 A.
Reference: NFPA 70, National Electrical Code, 2020, 240.4(B); 240.6(A)
What is the minimum size copper grounding electrode conductor for a service using 4/0 AWG copper ungrounded conductors, when the conductor connects to a metal underground water pipe electrode?
Answer: 2 AWG
Table 250.66 lists 2 AWG copper for service conductors over 3/0 through 350 kcmil. 4/0 AWG is in that range. 4 AWG is for 2/0 and 3/0, and 6 AWG is for 1 AWG and 1/0.
Reference: NFPA 70, National Electrical Code, 2020, Table 250.66
Using Table 310.16, what is the allowable ampacity of a 3 AWG copper THWN conductor (75 degrees C column)?
Answer: 100 A
Table 310.16 lists 3 AWG copper at 85 A (60 degrees C), 100 A (75 degrees C) and 115 A (90 degrees C). THWN is a 75 degrees C wet-rated type, so 100 A is used. The 2017 NEC printed this table as 310.15(B)(16).
Reference: NFPA 70, National Electrical Code, 2020, Table 310.16
Electrical metallic tubing must be supported at intervals no greater than what distance, and within what distance of each box or termination?
Answer: 10 ft and 3 ft
Section 358.30 requires EMT to be securely fastened at least every 10 ft and within 3 ft of each outlet box, junction box, cabinet or fitting. Longer unsupported spans are allowed only in the listed exceptions.
Reference: NFPA 70, National Electrical Code, 2020, 358.30(A)
In which location do ignitable concentrations of flammable gases or vapors exist under normal operating conditions?
Answer: Class I, Division 1
Section 500.5(B)(1) defines Class I, Division 1 as a location where ignitable concentrations of flammable gases or vapors exist under normal operating conditions (and in some cases from repair or leakage). Division 2 locations have them only under abnormal conditions, such as container failure.
Reference: NFPA 70, National Electrical Code, 2020, 500.5(B)(1)
What is the minimum clearance between a surface-mounted incandescent luminaire with a completely enclosed light source and the nearest point of storage space in a clothes closet?
Answer: 12 in.
Section 410.16(C)(1) requires 12 in. between a surface-mounted incandescent or LED luminaire with a completely enclosed light source and the storage space; surface fluorescent luminaires require 6 in. under 410.16(C)(2).
Reference: NFPA 70, National Electrical Code, 2020, 410.16(C)
A 10 hp, 460-volt, 3-phase induction motor has a full-load current of 14 A in Table 430.250. What is the minimum ampacity of the branch-circuit conductors to a single continuous-duty motor?
Answer: 17.5 A
Section 430.22 requires conductors to have at least 125 percent of the motor full-load current from the table: 14 x 1.25 = 17.5 A. 14 A ignores the 125 percent rule, and 35 A is the maximum inverse-time breaker size (250 percent), not a conductor ampacity.
Reference: NFPA 70, National Electrical Code, 2020, 430.6(A)(1); 430.22; Table 430.250
What is the minimum size of the bonding or grounding conductor from a communications primary protector to the grounding electrode system?
Answer: 14 AWG copper
Section 800.100(A) requires an insulated copper grounding conductor not smaller than 14 AWG, with current-carrying capacity approximately that of the protector grounding conductor. Intersystem bonding is covered in 250.94, which uses a 6 AWG minimum.
Reference: NFPA 70, National Electrical Code, 2020, 800.100(A)
Sources
- PSI: New Mexico Journeyman Candidate Information Bulletin (updated 4/13/2023) (opens in a new tab)
- New Mexico Construction Industries Division: Exams (opens in a new tab)
- PSI: New Mexico Construction Industries exams (opens in a new tab)
Questions last verified November 2, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.