Requirements at a glance
| Agency | New Mexico Regulation and Licensing Department, Construction Industries Division (CID); exams by PSI |
|---|---|
| Exam | 80 questions, 180 minutes, 75% to pass, open book |
| Books allowed | NEC 2020 (or NEC Handbook) and New Mexico Electrical Code NMAC 14.10.4 (2020) |
| Fees | Exam fees are paid to PSI (see the exam details above); license fees are separate. Check CID for current license fees. |
| Timing | Test within 6 months of becoming eligible. The exam fee and a passing score are each valid for 1 year. |
Contractors applying to Construction Industries Division for an ER-1 residential electrical license. You also need the Business and Law exam.
Official links
How to get licensed, step by step
Apply to CID through PSI
Candidates must be pre-approved before they can schedule. Submit your application and proof of qualifications through PSI's New Mexico construction page, or call PSI's approvals line at 877-663-9267.
PSI: apply and schedule New Mexico exams (opens in a new tab)New Mexico Construction Industries Division (CID) (opens in a new tab)
Get your references
Buy the exact code editions in PSI's bulletin. Books must be bound; highlighting, underlining and permanent tabs are allowed, but no loose notes or Post-its.
PSI Contractor Candidate Information Bulletin (opens in a new tab)New Mexico Administrative Code (NMAC) titles (opens in a new tab)
Schedule and pay PSI
After approval, contact PSI to schedule a seat and pay. Test sites include Albuquerque, Farmington, Las Cruces, Roswell and Santa Fe.
PSI: apply and schedule New Mexico exams (opens in a new tab)
Pass and finish your license
You need 75%. You may not take the same exam more than twice in 30 days. Contractors also need the Business and Law exam; journeyman candidates take a hands-on practical exam too.
New Mexico Construction Industries Division (CID) (opens in a new tab)PSI Contractor Candidate Information Bulletin (opens in a new tab)
How to prepare
- New Mexico tests the 2020 NEC. Do not study from a 2023 NEC; some rules changed between editions.
- General knowledge (17) and services, feeders and branch circuits (17) are 34 of 80 questions: know dwelling load calculations and Article 210 and 230 rules.
- 6 questions are New Mexico State Code, so tab NMAC 14.10.4. You also need the Business and Law exam.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2020 Edition (or the NEC Handbook)Essential
Bring your own, bound. New Mexico tests the 2020 edition, not 2023.
New Mexico Electrical Code (NMAC 14.10.4), 2020
State amendments; each exam has New Mexico State Code questions.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2020 edition, or the NEC Handbook
- New Mexico Electrical Code (NMAC 14.10.4), 2020
- PSI lists American Electricians' Handbook (17th Edition) and Ugly's Electrical References (2008, 2011 or 2014) as references not allowed in the room
What's on the exam
Official content outline from PSI, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge and Electrical Installation Requirements | 17 | |
| Services, Feeders, and Branch Circuits | 17 | |
| Overcurrent Protection | 4 | |
| Grounding and Bonding | 8 | |
| Conductors and Cables | 9 | |
| Raceways and Boxes | 9 | |
| Special Occupancies and Special Equipment, including Pools | 3 | |
| Lighting and General-Use Equipment | 3 | |
| New Mexico State Code | 6 | |
| Low Voltage | 4 |
Exam day details
- Administered by PSI, for the New Mexico Regulation and Licensing Department, Construction Industries Division (CID).
- Fee: $107.63, paid to PSI. License and application fees are separate.
- 80 questions in 180 minutes; 75% to pass (60 points).
- Open book. Bring bound references; you may highlight, underline and index them with permanent tabs only. No loose papers, notes or Post-it tabs, and no writing in the books.
- New Mexico tests the 2020 NEC plus NMAC 14.10.4, not the 2023 NEC.
- Get CID pre-approval through PSI first (PSI approvals line 877-663-9267). Once you are eligible you must test within 6 months, or reapply with the Division. Your exam fee is valid for 1 year and a passing score is valid for 1 year.
- You may not take the same exam more than twice in a 30-day period; after two fails you must wait 30 days from your first attempt.
- General knowledge and installation requirements (17) and services, feeders and branch circuits (17) are 34 of the 80 questions; 6 are New Mexico State Code.
Frequently asked questions
What's on the New Mexico ER-1 exam?
PSI's outline, 80 questions: General Knowledge and Electrical Installation Requirements 17; Services, Feeders, and Branch Circuits 17; Overcurrent Protection 4; Grounding and Bonding 8; Conductors and Cables 9; Raceways and Boxes 9; Special Occupancies and Special Equipment, including Pools 3; Lighting and General-Use Equipment 3; New Mexico State Code 6; Low Voltage 4.
Which code editions does the New Mexico exam use?
PSI's bulletin pins the editions: for electrical, the 2020 NEC plus the New Mexico Electrical Code (NMAC 14.10.4); for plumbing and gas, the 2021 UPC and UMC plus the New Mexico plumbing and mechanical codes (NMAC 14.8.2 and 14.9.2); for building, the 2021 IRC or IBC plus NMAC 14.7.3 or 14.7.2. Code questions use only the listed edition.
Who gives the New Mexico contractor and journeyman exams?
PSI, for the Construction Industries Division (CID) of the Regulation and Licensing Department. CID pre-approves your application, then you schedule with PSI at a New Mexico test center (Albuquerque, Farmington, Las Cruces, Roswell or Santa Fe) or an approved center elsewhere.
Free questions with answers
Show all 10 free questions and answers
A homeowner wants a storage shelf directly above a new indoor panelboard. Under the dedicated equipment space rule, how far above the panelboard must the space equal to its width and depth be kept clear of foreign equipment?
Answer: 6 ft above the equipment or to the structural ceiling, whichever is lower
110.26(E)(1)(a) reserves the space equal to the width and depth of the equipment from the floor to 6 ft above the equipment or to the structural ceiling, whichever is lower, for electrical installations only. A storage shelf in that zone is not allowed. 6 ft 6 in. is the working-space headroom in 110.26(A)(3), a different rule.
Reference: NFPA 70, National Electrical Code, 2020, 110.26(E)(1)(a)
A one-family dwelling has 2,200 sq ft of livable floor area. What is the general lighting load before demand factors?
Answer: 6,600 VA
In the 2020 NEC the dwelling unit load is in 220.14(J) (Table 220.12 now lists non-dwelling occupancies only): 3 VA per sq ft, so 2,200 x 3 = 6,600 VA. 4,400 VA uses 2 VA/sq ft, 5,500 VA uses 2.5 VA/sq ft and 7,700 VA uses 3.5 VA/sq ft.
Reference: NFPA 70, National Electrical Code, 2020, 220.14(J)
Where does the NEC prohibit locating a dwelling's panelboard because of nearby easily ignitible material?
Answer: In a clothes closet
240.24(D) says overcurrent devices may not be located in the vicinity of easily ignitible material, such as in clothes closets. Garages, basements and exterior walls are common, permitted panel locations if working-space rules in 110.26 are met.
Reference: NFPA 70, National Electrical Code, 2020, 240.24(D)
A dwelling service uses 2/0 AWG copper service-entrance conductors. The grounding electrode conductor runs to a metal underground water pipe. Using Table 250.66, what is the minimum copper GEC size?
Answer: 4 AWG
Table 250.66 requires 4 AWG copper for 2/0 or 3/0 AWG copper service conductors. 6 AWG is for 1 or 1/0 AWG, 2 AWG is for over 3/0 through 350 kcmil, and 8 AWG is for 2 AWG or smaller. The water-pipe electrode does not get the size cap that rods and concrete-encased electrodes get.
Reference: NFPA 70, National Electrical Code, 2020, Table 250.66
Six current-carrying 12 AWG copper THHN conductors (30 A at 90 degrees C) share one raceway at 30 degrees C. What is their adjusted ampacity?
Answer: 24 amperes
Table 310.15(C)(1) requires 80% for 4 to 6 current-carrying conductors: 30 x 0.80 = 24 A. 21 A uses the 70% factor for 7 to 9 conductors, and 15 A uses 50% for 10 to 20. The 20-A overcurrent limit of 240.4(D) still applies to 12 AWG copper.
Reference: NFPA 70, National Electrical Code, 2020, 310.15(C)(1); Table 310.15(C)(1)
A metal device box contains two 14-2 NM cables with ground (four insulated 14 AWG conductors and two grounds), one single-pole switch and internal cable clamps. Using 2.00 cu in. per 14 AWG, what is the minimum box volume required?
Answer: 16.0 cu in.
314.16(B): four insulated conductors = 4; all equipment grounding conductors together = 1; the switch (one yoke) = 2; internal clamps (one or more) = 1. Total 8 x 2.00 = 16.0 cu in. 18.0 counts each ground separately, 14.0 omits the clamps, and 12.0 also counts the switch as one.
Reference: NFPA 70, National Electrical Code, 2020, 314.16(B); Table 314.16(B)
A permanently installed swimming pool is added at a dwelling. Where must the required general-purpose 125-volt, 15- or 20-ampere receptacle be located?
Answer: 6 ft to 20 ft from the pool's inside wall
680.22(A)(2) requires at least one 125-volt, 15- or 20-ampere receptacle on a general-purpose branch circuit located not less than 6 ft from and not more than 20 ft from the inside wall of a permanently installed pool at a dwelling, and not more than 6 1/2 ft above the floor or grade. Receptacles closer than 6 ft are not permitted except as allowed for pump motors.
Reference: NFPA 70, National Electrical Code, 2020, 680.22(A)(2)
A surface-mounted LED luminaire with a completely enclosed light source is installed on the ceiling of a bedroom clothes closet. What is the minimum clearance to the defined storage space?
Answer: 12 in.
410.16(C)(1) requires 12 in. between the storage space and surface-mounted incandescent or LED luminaires with a completely enclosed light source on the wall above the door or on the ceiling. Recessed luminaires and surface-mounted fluorescent luminaires need only 6 in., and LED or fluorescent luminaires identified for use within the storage space have their own rule in 410.16(C)(5).
Reference: NFPA 70, National Electrical Code, 2020, 410.16(C)(1)
A doorbell transformer's Class 2 secondary wires are to enter a 120-volt switch box that has no barrier. What does the NEC say?
Answer: Not allowed in the same enclosure without a barrier
725.136(A) says Class 2 cables and conductors may not be placed in any cable, cable tray, compartment, enclosure, manhole, outlet box, device box, raceway or similar fitting with conductors of electric light, power or Class 1 circuits, unless permitted by 725.136(B) through (I), such as separation by a barrier. Insulation rating, taping or box grounding is not an exception.
Reference: NFPA 70, National Electrical Code, 2020, 725.136(A), (B)
Under the New Mexico Electrical Code, how must smoke detectors in a new single-family dwelling be supplied and connected?
Answer: Individual branch circuit, interconnected by multi-conductor cable
NMAC 14.10.4.17 requires smoke detectors in new single-family dwellings to be served by an individual branch circuit, and where two or more are required they must be interconnected with a multi-conductor cable assembly. Location and battery backup follow the adopted New Mexico residential building code.
Reference: NMAC 14.10.4 (2020 NEC as amended), 14.10.4.17
Sources
- PSI: New Mexico Contractor Candidate Information Bulletin (updated 4/3/2026) (opens in a new tab)
- New Mexico Construction Industries Division: Exams (opens in a new tab)
- PSI: New Mexico Construction Industries exams (opens in a new tab)
Questions last verified November 3, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.