New Hampshire licensing exam

New Hampshire Journeyman Plumber Exam: Practice Test & Licensing Guide

The Prov exam for New Hampshire's journeyman plumber license: 85 open-book questions in 3 hours on venting, drainage, water distribution, fixtures, traps and calculations from the 2018 IPC. 70% to pass.

Questions
85
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Venting Regulations (Journey Level)

An individual vent serves a fixture whose drain is 3 inches in diameter, and the vent's developed length is 25 feet. What is the smallest vent pipe permitted?

Requirements at a glance

AgencyNew Hampshire Mechanical Safety and Licensing Board (OPLC); exam by Prov
Exam85 questions, 3 hours, open book, 70% to pass
ExperienceApprenticeship completion certificate, 600 hours of education and 8,000 on-the-job hours; or an out-of-state journeyman license (Mec 305.01(b))
Books allowed2018 IPC; Purpose and Scope of Administrative Rules of the Board
Fees$90 to Prov; initial 2-year license fee is $198 (Plc 1002.25)

Plumbers applying to the New Hampshire Mechanical Safety and Licensing Board for a journeyman license. You need an apprenticeship completion certificate with 600 hours of education and 8,000 on-the-job hours (or an out-of-state journeyman license) before the board approves you to test (Mec 305.01(b)).

How to get licensed, step by step

  1. Qualify with the board

    Finish your apprenticeship with at least 600 hours of education and 8,000 hours of on-the-job experience (or hold an out-of-state journeyman license), then apply to the Mechanical Safety and Licensing Board. An apprentice license needs a sponsoring master plumber (Mec 304.04(c)), and each plumbing licensee may employ no more than 2 apprentices (RSA 153:27, XV).

    New Hampshire Mechanical Safety and Licensing Board (OPLC) (opens in a new tab)Mec 100-600 (Mechanical Licensing Board rules) (opens in a new tab)

  2. Get pre-approved

    The board must approve you and pass your registration to Prov before you can schedule.

    New Hampshire Mechanical Safety and Licensing Board (OPLC) (opens in a new tab)

  3. Schedule with Prov

    After the board pre-approves you, book at provexam.com/scheduler (New Hampshire centers, or remote through Examroom). There is no waiting period between attempts. You can reschedule free up to 3 days ahead.

    Schedule with Prov (opens in a new tab)Prov: New Hampshire Mechanical Board (Gas & Plumbing) Candidate Information Bulletin (opens in a new tab)

  4. Get licensed

    Prov sends your result to the board, which issues the license.

    New Hampshire Mechanical Safety and Licensing Board (OPLC) (opens in a new tab)

How to prepare

  • Venting (20) and drainage (15) are 35 of 85 questions; tab IPC Chapters 3, 5, 6 and 9.
  • Ten questions are calculations: practice pipe and fixture-unit sizing with the 2018 IPC tables.
  • New Hampshire's building code now adopts the 2024 IPC, but the Prov bulletin still lists the 2018 IPC. Study the edition the bulletin names.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Plumbing Code 2018, ICC (open book)
  • Purpose and Scope of Administrative Rules of the Board (open book)

What's on the exam

Official content outline from Prov, Inc. (number of questions per topic):

TopicQuestions
Venting Regulations (Journey Level)20
Drainage Requirements (Journey Level)15
Water Distribution (Journey Level)10
Fixtures and Faucets (Journey Level)10
Plumbing Fundamentals (Journey Level)10
Traps and Interceptors (Journey Level)10
Calculations (Journey Level)10

Exam day details

  • Administered by Prov, Inc. for the New Hampshire Office of Professional Licensure and Certification.
  • Fee: $90 to Prov. Board application and license fees are separate.
  • 85 questions in 3 hours; 60 correct (70%) to pass.
  • Open book: the references above are permitted in the exam room.
  • The Mechanical Board must pre-approve you; Prov then lets you schedule at a New Hampshire test center or remotely through Examroom.
  • There is no required waiting period between attempts. You can reschedule free up to 3 days before your appointment.

Note: New Hampshire's building code (RSA 155-A:1) now adopts the 2024 IPC, but the Prov bulletin still lists the 2018 IPC for this exam. We follow the printed bulletin. Check the current bulletin before your test date.

Frequently asked questions

What's on the New Hampshire journeyman plumber exam?

85 questions: venting 20, drainage 15, water distribution 10, fixtures and faucets 10, plumbing fundamentals 10, traps and interceptors 10 and calculations 10.

Which plumbing code is on the exam?

Prov's bulletin lists the 2018 International Plumbing Code, even though the state building code now adopts the 2024 IPC. Check the current bulletin before you buy a book.

Do I need approval before I schedule?

Yes. The Mechanical Safety and Licensing Board pre-approves you and gives Prov your registration information.

Free questions with answers

Show all 10 free questions and answers
  1. An individual vent serves a fixture whose drain is 3 inches in diameter, and the vent's developed length is 25 feet. What is the smallest vent pipe permitted?

    Answer: 1-1/2 inches

    Individual vents must be at least one-half the required diameter of the drain served, and never less than 1-1/4 inches. Half of 3 inches is 1-1/2 inches. At 25 feet the 40-foot increase does not apply. A full-size 3-inch vent is not required.

    Reference: 2018 International Plumbing Code, 906.2

  2. A 3-inch fixture drain is installed at 1/8 inch per foot. What is the maximum total fall in this drain allowed by the vent rules, and what is the code's limit on trap-to-vent distance for it?

    Answer: 3 inches of fall; 12 feet

    The total fall in a fixture drain due to slope may not exceed the drain diameter, so 3 inches for a 3-inch drain. Table 909.1 lists 12 feet for a 3-inch trap at 1/8 inch per foot. The 16-foot value is for 4-inch traps and 8 feet for 2-inch traps.

    Reference: 2018 International Plumbing Code, 909.2; Table 909.1

  3. What is the minimum slope for a 4-inch horizontal drainage pipe inside a building?

    Answer: 1/8 inch per foot

    Table 704.1 requires 1/4 inch per foot for pipes 2-1/2 inches or smaller, 1/8 inch per foot for 3 through 6 inches, and 1/16 inch per foot for 8 inches and larger. A 4-inch pipe falls in the 1/8 inch group.

    Reference: 2018 International Plumbing Code, Table 704.1

  4. A 4-inch drainage stack has a horizontal offset. A horizontal branch is to connect to that offset. How far downstream of the upper stack must the connection be made?

    Answer: At least 40 inches

    Horizontal branches must connect to the base of a stack, or to a horizontal stack offset, at least 10 times the diameter of the drainage stack downstream. 10 x 4 inches = 40 inches.

    Reference: 2018 International Plumbing Code, 704.3

  5. What is the smallest permitted diameter for a water service pipe?

    Answer: 3/4 inch

    The water service pipe must be sized for the required quantities and pressures, and may not be less than 3/4 inch in diameter. 1/2 inch is allowed for some fixture supplies, but not for the service.

    Reference: 2018 International Plumbing Code, 603.1

  6. What is the maximum temperature that a tempered water supply from a limiting device may deliver?

    Answer: 110 degrees F

    Tempered water must be supplied through a temperature limiting device conforming to ASSE 1070 that limits the tempered water to 110 degrees F or less. A water heater thermostat does not count as the limiting means.

    Reference: 2018 International Plumbing Code, 607.1.2

  7. What maximum temperature setting must an individual shower valve be able to be limited to?

    Answer: 120 degrees F, field adjusted per the manufacturer

    Individual shower and tub-shower valves must be pressure balancing, thermostatic or combination valves at the point of use, with a means to limit the maximum setting to 120 degrees F, adjusted in the field. A water heater thermostat does not satisfy this, and in-line thermostatic valves may not be used.

    Reference: 2018 International Plumbing Code, 412.3

  8. What liquid seal depth is required for a fixture trap?

    Answer: Not less than 2 inches and not more than 4 inches

    Each fixture trap must have a liquid seal of at least 2 inches and no more than 4 inches, or deeper for special designs relating to accessible fixtures.

    Reference: 2018 International Plumbing Code, 1002.4

  9. What is the maximum horizontal support spacing for steel pipe?

    Answer: 12 feet

    Table 308.5 allows steel pipe 12 feet horizontally and 15 feet vertically. 10 feet is the horizontal value for brass pipe and large copper tubing.

    Reference: 2018 International Plumbing Code, Table 308.5

  10. A single-family house has two bathroom groups (each with a 1.6 gpf water closet), a kitchen sink with a dishwasher, a residential clothes washer and a laundry tray. Using Table 709.1, what is the total drainage fixture unit load?

    Answer: 16 dfu

    Table 709.1 values: bathroom group with a 1.6 gpf closet = 5 each; kitchen sink, domestic, with dishwasher = 2 (the table lists the combination as one entry); residential clothes washer = 2; laundry tray = 2. Total = 5 + 5 + 2 + 2 + 2 = 16 dfu. 14 omits the laundry tray, and 18 adds the dishwasher separately (2 more) even though the sink entry already includes it.

    Reference: 2018 International Plumbing Code, Table 709.1

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.