Requirements at a glance
| Agency | New Hampshire Electricians' Board (OPLC); exam by Prov |
|---|---|
| Exam | 110 questions, 4.5 hours, open book, 70% to pass |
| Experience | 8,000 hours as an apprentice electrician and 600 hours of education (RSA 319-C:7) |
| Books allowed | 2020 NEC; 2023 NEC; Ugly's Electrical References (2020); NH Laws and Rules Elec 300-400 / RSA 319-C; American Electrician's Handbook 17th ed.; NH 2017 NEC amendments (210.12, HB85 Ch. 157, EL170217, EL170117) |
| Fees | $90 to Prov; board application and license fees are separate |
Electricians applying to the New Hampshire Electricians' Board for a journeyman license. State law (RSA 319-C:7) calls for 8,000 hours as an apprentice electrician, at least 600 hours of education and a passing exam score.
Official links
- New Hampshire Electricians' Board (OPLC) (opens in a new tab)
- Prov: New Hampshire Electrician Board Candidate Information Bulletin (opens in a new tab)
- Schedule with Prov (opens in a new tab)
- RSA 319-C (electricians) (opens in a new tab)
- Elec 100-400 (Electricians' Board rules) (opens in a new tab)
- 2020 NEC Amendments Bulletin (OPLC) (opens in a new tab)
- Electricians' Board resources (OPLC) (opens in a new tab)
How to get licensed, step by step
Meet the apprenticeship and education requirements
RSA 319-C:7 calls for 8,000 hours as a registered apprentice electrician and at least 600 hours of education that meet the board's criteria. The board can credit approved school courses or military experience.
New Hampshire Electricians' Board (OPLC) (opens in a new tab)RSA 319-C (electricians) (opens in a new tab)
Apply to the Electricians' Board
Send the application and fee to the board (OPLC, Concord). Check the board's page for the current forms.
New Hampshire Electricians' Board (OPLC) (opens in a new tab)
Register and schedule with Prov
Register at provexam.com/scheduler and choose "NH - New Hampshire Electrician Board" (4 New Hampshire centers, or remote through Examroom). If you fail, wait 30 days; there is no attempt limit. You can reschedule free up to 3 days ahead.
Schedule with Prov (opens in a new tab)Prov: New Hampshire Electrician Board Candidate Information Bulletin (opens in a new tab)
Get licensed
Prov grades the exam immediately and sends your result to the board, which issues the license.
New Hampshire Electricians' Board (OPLC) (opens in a new tab)
How to prepare
- General electrical knowledge (22) and motors and generators (19) are 41 of 110 questions.
- Tab your NEC for Chapter 9 tables, Article 310 ampacities, Article 430 motors and Article 250 grounding, and bring the New Hampshire amendments (printed copies are allowed).
- The exam is written to the 2020 NEC plus the state amendments. The Prov bulletin also allows the 2023 NEC open book (the state building code now adopts the 2023 NEC, with a concurrency period to Dec. 31, 2026). Answers follow the 2020 edition.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2020 National Electrical Code (NEC), NFPA 70Essential
Allowed in the exam room. Most of the electrician exam comes from it.
Ugly's Electrical References, 2020
Allowed in the exam room. Quick tables and formulas.
American Electrician's Handbook, 17th Edition
Allowed in the exam room. Tables, formulas and theory for the electrician exams.
Official reference list (as published by the testing agency)
- NFPA 70 National Electrical Code, 2020 (open book)
- NFPA 70 National Electrical Code, 2023 (open book; the exam is written to the 2020 edition)
- Ugly's Electrical References, 2020 (open book)
- New Hampshire Laws and Rules Elec 300-400 and RSA 319-C (open book; printed copies allowed)
- American Electrician's Handbook, 17th Edition, McGraw Hill (open book)
- New Hampshire amendments to the NEC: EL170117, EL170217, HB85 Chapter 157 and the 210.12 amendment (open book)
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 22 | |
| Equipment for General Use | 9 | |
| Motors and Generators | 19 | |
| Control Devices | 5 | |
| Special Conditions | 2 | |
| Special Equipment | 2 | |
| Special Occupancies | 2 | |
| Services and Service Equipment | 12 | |
| Branch Circuits and Conductors | 6 | |
| Feeders | 8 | |
| Wiring Methods & Materials | 14 | |
| Administrative | 9 |
Exam day details
- Administered by Prov, Inc. for the New Hampshire Office of Professional Licensure and Certification.
- Fee: $90 to Prov. Board application and license fees are separate.
- 110 questions in 4.5 hours; 77 correct (70%) to pass.
- Open book: the references above are permitted in the exam room.
- Register directly with Prov (choose "NH - New Hampshire Electrician Board"), then schedule at one of 4 New Hampshire test centers or remotely through Examroom.
- If you fail, wait 30 days to retake. There is no limit on attempts. You can reschedule free up to 3 days before your appointment.
Note: New Hampshire's building code (RSA 155-A:1) now adopts the 2023 NEC, with a concurrency period to December 31, 2026. The Prov bulletin (effective October 31, 2026) still writes this exam to the 2020 NEC but allows both the 2020 and 2023 NEC open book. We follow the 2020 edition. Check the current bulletin before your test date.
Frequently asked questions
What's on the New Hampshire journeyman electrician exam?
110 questions: general electrical knowledge 22, motors and generators 19, wiring methods and materials 14, services and service equipment 12, equipment for general use 9, administrative 9, feeders 8, branch circuits and conductors 6, control devices 5, and special conditions, special equipment and special occupancies 2 each.
Which NEC edition is on the exam?
The exam is written to the 2020 NEC plus New Hampshire's amendments. Prov's bulletin allows both the 2020 and the 2023 NEC open book; the state building code now adopts the 2023 NEC. Check the current bulletin before your test date.
Who gives the exam?
Prov. You register with Prov directly and pay the exam fee to Prov; the Electricians' Board handles your application and license.
Free questions with answers
Show all 10 free questions and answers
A 480Y/277-volt panelboard has exposed live parts behind its dead front when opened. The wall directly across the work aisle is grounded concrete, and nothing live is on that side. What minimum depth of clear working space does Table 110.26(A)(1) require in front of the panelboard?
Answer: 3 ft 6 in., because grounded parts are opposite the exposed live parts
Table 110.26(A)(1) for 151 to 600 volts to ground gives 3 ft (Condition 1: live parts on one side, nothing live or grounded opposite), 3 ft 6 in. (Condition 2: live parts on one side, grounded parts opposite) and 4 ft (Condition 3: exposed live parts on both sides). A grounded concrete wall is a grounded part, so Condition 2 applies. The 277-volt-to-ground value places it in the 151-600 V row.
Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, Table 110.26(A)(1)
Under RSA 319-C:7, II, a person applying for a New Hampshire journeyman electrician license must complete how many hours of service as an apprentice electrician?
Answer: 8,000 hours
RSA 319-C:7, II(a) requires 8,000 hours of service as an apprentice electrician (with limited credit for approved schooling or military experience), at least 600 hours of education under (b), and a passing exam under (c). The 2,000-hour figure is the journeyman experience needed before taking the master exam (Elec 304.01(f)).
Reference: New Hampshire RSA 319-C (Electricians), RSA 319-C:7, II(a)
Under the Article 100 definition, a motor disconnecting means that must be "in sight from" the motor has to be located how?
Answer: Visible from the motor and not more than 50 ft away
Article 100 defines in sight from as visible and not more than 50 ft (15 m) distant from the equipment. The term is used in Article 430 to locate the motor disconnecting means or controller disconnect relative to the motor.
Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, Article 100, In Sight From (Within Sight From, Within Sight)
Which luminaire type may be installed in a clothes closet under 410.16?
Answer: A surface-mounted luminaire with a completely enclosed light source
410.16(A) permits only surface-mounted or recessed incandescent or LED luminaires with completely enclosed light sources, surface-mounted or recessed fluorescent luminaires, and surface-mounted fluorescent or LED luminaires identified for the clothes closet storage space. 410.16(B) prohibits incandescent luminaires with open or partially enclosed lamps and pendant luminaires or lampholders.
Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 410.16(A), (B)
Under 430.75(A), what must be true of a motor control circuit when the motor disconnecting means is in the open position?
Answer: The control circuit is disconnected from all supply sources
Motor control circuits must be arranged so they are disconnected from all sources of supply when the disconnecting means is open. The disconnect may be two or more devices adjacent to each other, one for the motor and controller and one for the control circuit.
Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 430.75(A)
A legally required standby system under Article 701 serves a building's smoke-control fans. What is the maximum time allowed for the standby supply to be available after a normal power failure?
Answer: 60 seconds
701.12 requires a legally required standby system to have power available within 60 seconds of failure of the normal source. The 10-second limit applies to emergency systems under 700.12.
Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 701.12
Which service must have ground-fault protection of equipment under 230.95?
Answer: A 480Y/277-volt, 3-phase, 4-wire service with a 1,200-ampere disconnect
230.95 requires ground-fault protection of equipment for solidly grounded wye services of more than 150 volts to ground and not over 1,000 volts phase to phase where the service disconnect is rated 1,000 amperes or more. 480Y/277 volts qualifies at 1,200 A. 208Y/120 volts has only 120 volts to ground, and the 800 A service is below 1,000 A.
Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 230.95
Under the New Hampshire amendment to NEC 210.12, what is permitted for the AFCI devices required by 210.12(A), (B) and (C)?
Answer: They may be removed and replaced with non-AFCI devices as permitted by RSA 155-A:3-c
New Hampshire's amended 210.12 keeps the requirement that the arc-fault circuit interrupter be installed in a readily accessible location, and adds an exception allowing AFCI devices required by 210.12(A), (B) and (C) to be removed and replaced with non-AFCI devices as permitted by RSA 155-A:3-c (repeated unwanted tripping not caused by the branch circuit; outlets marked or occupants notified; NEMA tripping report within 5 working days). The amendment also strikes the 2020 guest room/guest suite AFCI rule, so (C) in the New Hampshire text is the branch-circuit extension rule.
Reference: New Hampshire 2020 NEC Amendments (OPLC Electricians' Board bulletin; NFPA 70, 2020 edition, as amended, eff. July 1, 2022), Amend Section 210.12 (EL-20-06-21); RSA 155-A:3-c
A feeder will carry 100 amperes of continuous load and 40 amperes of noncontinuous load. The breaker and terminations are rated 75 degrees C and the breaker is not listed for 100 percent continuous operation. Using Table 310.16, what is the smallest copper conductor?
Answer: 2/0 AWG
215.2(A)(1) requires ampacity of at least the noncontinuous load plus 125 percent of the continuous load: 100 x 1.25 + 40 = 125 + 40 = 165 A. In the 75 degree C column of Table 310.16, 1/0 AWG is 150 A (too small) and 2/0 AWG is 175 A, which meets 165 A. 4/0 AWG is larger than needed.
Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 215.2(A)(1); Table 310.16
Type UF cable supplies an outdoor 120-volt, 20-ampere GFCI-protected branch circuit at a one-family dwelling and is direct buried in a lawn. Using Table 300.5, what is the minimum cover?
Answer: 12 in.
Table 300.5 gives 12 in. of cover for residential branch circuits rated 120 volts or less, with GFCI protection and overcurrent protection not over 20 amperes (Column 4). The standard direct-burial depth for UF cable without those conditions is 24 in., and 18 in. applies to rigid nonmetallic conduit in open ground.
Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, Table 300.5, Column 4
Sources
- Prov: New Hampshire Electrician Board Candidate Information Bulletin (opens in a new tab)
- New Hampshire Electricians' Board (OPLC) (opens in a new tab)
- RSA 319-C (electricians) (opens in a new tab)
- 2020 NEC Amendments Bulletin (OPLC) (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.