New Hampshire licensing exam

New Hampshire Electrical Re-Licensing Exam (2020 NEC): Practice Test & Licensing Guide

The Prov re-licensing exam for New Hampshire electricians: 25 open-book questions in 125 minutes on the 2020 NEC. 70% to pass.

Questions
25
Time limit
2.0833333333333335 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Electrical Knowledge

Unguarded 480-volt (between ungrounded conductors) live parts in a room are to be protected against accidental contact by elevation above the floor instead of by an enclosure. What is the minimum elevation under 110.27(A)?

Requirements at a glance

AgencyNew Hampshire Electricians' Board (OPLC); exam by Prov
Exam25 questions, 125 minutes, open book, 70% to pass
Who takes itMaster or journeyman electricians whose license lapsed more than one year; Elec 402.01(a) requires them to pass the licensing examination or apply for the exam that matches the expired license
Books allowed2020 NEC
Fees$70 to Prov; relicensing application fee is $25 (Elec 305.04); license fees are separate

Master and journeyman electricians whose New Hampshire license has lapsed. Elec 402.01(a) says: "Any master or journeyman electrician whose license is not renewed within one year of the expiration date of the license shall: (1) Meet the requirements of this section and pass the licensing examination set forth in Elec 305; or (2) Apply to take the master or journeyman examination, as determined by the expired license." Elec 305.01(e) says the relicensing examination consists of questions based on the NEC. Lapse of more than one year also brings continuing education (a 15-hour NEC course for 1 to 3 years, with more hours or out-of-state work for longer lapses), and a lapse of 10 years or more without licensure in another state means retaking the initial exam. The board decides which exam you take, so confirm with the Electricians' Board.

How to get licensed, step by step

  1. Check what your lapse requires

    Elec 402.01 sets continuing education by length of lapse: a 15-hour NEC course for 1 to 3 years, more hours (or out-of-state work) for 3 to 10 years, and the initial exam after 10 years without licensure in another state. Ask the board which exam applies to you.

    New Hampshire Electricians' Board (OPLC) (opens in a new tab)Elec 100-400 (Electricians' Board rules) (opens in a new tab)

  2. Apply to the Electricians' Board

    Send the relicensing application, a statement of previous licensure and proof of continuing education. Check the board's page for the current forms.

    New Hampshire Electricians' Board (OPLC) (opens in a new tab)

  3. Register and schedule with Prov

    Register at provexam.com/scheduler and choose "NH - New Hampshire Electrician Board" (4 New Hampshire centers, or remote through Examroom). If you fail, wait 30 days; there is no attempt limit. You can reschedule free up to 3 days ahead.

    Schedule with Prov (opens in a new tab)Prov: New Hampshire Electrician Board Candidate Information Bulletin (opens in a new tab)

  4. Get licensed

    Prov grades the exam immediately and sends your result to the board.

    New Hampshire Electricians' Board (OPLC) (opens in a new tab)

How to prepare

  • Only 25 questions, spread across nine NEC areas: general electrical knowledge and control devices are 4 each.
  • Elec 305.01(e) describes the relicensing exam as NEC questions only, so there is no separate practical or law section.
  • New Hampshire's building code now adopts the 2023 NEC (concurrency period to Dec. 31, 2026), but the Prov bulletin lists only the 2020 NEC for the master exam. Confirm the edition before you buy a book.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2020 National Electrical Code (NEC), NFPA 70Essential

    Allowed in the exam room. Most of the electrician exam comes from it.

    NFPA (opens in a new tab)

Official reference list (as published by the testing agency)
  • NFPA 70 National Electrical Code, 2020 (open book; the only reference the bulletin lists)

What's on the exam

Official content outline from Prov, Inc. (number of questions per topic):

TopicQuestions
General Electrical Knowledge4
Equipment for General Use3
Motors and Generators2
Control Devices4
Special Conditions2
Services and Service Equipment3
Branch Circuits and Conductors2
Feeders2
Wiring Methods & Materials3

Exam day details

  • Administered by Prov, Inc. for the New Hampshire Office of Professional Licensure and Certification.
  • Fee: $70 to Prov. The board's relicensing application fee ($25 under Elec 305.04) and license fees are separate.
  • 25 questions in 125 minutes; 18 correct (70%) to pass.
  • Open book: the 2020 NEC is permitted in the exam room.
  • Register directly with Prov (choose "NH - New Hampshire Electrician Board"), then schedule at one of 4 New Hampshire test centers or remotely through Examroom.
  • If you fail, wait 30 days to retake. There is no limit on attempts. You can reschedule free up to 3 days before your appointment.

Note: New Hampshire's building code (RSA 155-A:1) now adopts the 2023 NEC, with a concurrency period to December 31, 2026, but the Prov bulletin (effective October 31, 2026) still lists the 2020 NEC for this exam. We follow the printed bulletin. Check the current bulletin before your test date. Elec 305.01(e) describes the relicensing exam as 20 NEC questions; Prov's bulletin prints 25, and we follow the bulletin.

Frequently asked questions

Who takes the New Hampshire electrical re-licensing exam?

Electricians whose license lapsed more than one year past its expiration date and who must pass an exam to be relicensed (Elec 402.01). The board decides which exam applies to you, so check with the Electricians' Board first.

What's on the exam?

25 questions: general electrical knowledge 4, control devices 4, equipment for general use 3, services and service equipment 3, wiring methods and materials 3, and motors and generators, special conditions, branch circuits and conductors, and feeders 2 each.

Which NEC edition is on the exam?

The Prov bulletin names the 2020 NEC, and that is the only open-book reference it lists. The state building code now adopts the 2023 NEC, so check the current bulletin before your test date.

Free questions with answers

Show all 10 free questions and answers
  1. Unguarded 480-volt (between ungrounded conductors) live parts in a room are to be protected against accidental contact by elevation above the floor instead of by an enclosure. What is the minimum elevation under 110.27(A)?

    Answer: 8 ft 6 in.

    110.27(A) lets live parts be guarded by elevation: 8 ft for 50 to 300 volts between ungrounded conductors and 8 ft 6 in. for 301 to 600 volts. A 480-volt system is in the higher band, so 8 ft is not enough. 6 ft 6 in. is the minimum working-space headroom, a different rule.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 110.27(A)(4)

  2. Which of these pieces of equipment is NOT required by 110.16(A) to carry an arc-flash hazard warning marking?

    Answer: A panelboard in a single-family dwelling unit

    110.16(A) applies to equipment such as switchboards, panelboards, industrial control panels, meter socket enclosures and motor control centers in other than dwelling units that is likely to be examined or serviced while energized. A dwelling-unit panelboard is excluded by the words 'other than dwelling units'.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 110.16(A)

  3. After installation, a duplex receptacle is mounted in a metal faceplate. Under 406.5(D), where must the receptacle face sit relative to the plate?

    Answer: Projecting at least 0.015 in. from the metal faceplate

    406.5(D) requires receptacle faces to be flush with or project from insulating faceplates and to project a minimum of 0.015 in. (0.4 mm) from metal faceplates. Flush is acceptable only for insulating plates, and a recessed face is not permitted. The 1/4 in. figure is not in the rule.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 406.5(D)

  4. Under 430.14(A), how must a motor be located with respect to ventilation and maintenance?

    Answer: Where ventilation is adequate and servicing is easy

    430.14(A) requires motors to be located so adequate ventilation is provided and maintenance such as lubricating bearings and replacing brushes can be done readily. The exception is submersible motors, which need no ventilation. Sealing a motor from air or fixing a standoff distance is not a Code requirement.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 430.14(A)

  5. In a three-way switch circuit, in which conductor must the switching take place under 404.2(A)?

    Answer: Only in the ungrounded circuit conductor

    404.2(A) requires three-way and four-way switches to be wired so that all switching is done only in the ungrounded (hot) circuit conductor. Switching the grounded conductor would leave the luminaire energized when off. The equipment grounding conductor must never be switched. Where wiring is in metal raceways or armored cable, 300.20(A) also applies.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 404.2(A)

  6. A building has an on-site generator that serves as the emergency source. Under 700.7(A), what sign must be placed at the service-entrance equipment?

    Answer: A sign indicating the type and location of each on-site emergency power source

    700.7(A) requires a sign at the service-entrance equipment indicating the type and location of each on-site emergency power source. Fuel capacity, test dates, contractor names and the utility's phone number are not part of the required sign.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 700.7(A)

  7. A service uses 500-kcmil copper conductors. A single ground rod is the only grounding electrode, and the grounding electrode conductor runs straight to the rod with no other connection. Under 250.66(A), what is the largest copper grounding electrode conductor the Code requires for this connection?

    Answer: 6 AWG

    Table 250.66 would give 1/0 AWG copper for 500-kcmil service conductors, but 250.66(A) says that the part of the grounding electrode conductor that is the sole connection to a rod, pipe or plate electrode is not required to be larger than 6 AWG copper. 4 AWG is the concrete-encased limit in 250.66(B), and 8 AWG is smaller than the minimum.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 250.66(A); Table 250.66

  8. Under New Hampshire's amended 210.8(A)(5), which of these dwelling receptacles must be GFCI protected?

    Answer: A 125-volt, 20-ampere receptacle in an unfinished basement

    New Hampshire amends 210.8(A) to the 125-volt, single-phase, 15- and 20-ampere wording and changes item (5) to read 'unfinished basements'. A receptacle in an unfinished basement therefore needs GFCI protection, while a finished family room, a dining room, or a 250-volt dryer receptacle is not covered by that list in New Hampshire.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, NH Amend Section 210.8(A) (EL-20-02-21), item (5)

  9. A 120/240-volt, single-phase, 3-wire feeder has these calculated loads: 85 amperes of 120-volt load connected to one ungrounded conductor, 60 amperes of 120-volt load connected to the other, and 40 amperes of 240-volt load. Under 220.61(A), what is the calculated neutral load (the maximum unbalanced load)?

    Answer: 85 amperes

    220.61(A) defines the maximum unbalanced load as the maximum net calculated load between the neutral conductor and any one ungrounded conductor. The 240-volt load is not connected to the neutral, so it is left out, and the heavier leg has 85 amperes of line-to-neutral load. The calculation assumes the other leg's loads may be off, so the 85 - 60 = 25 ampere difference is not used. 145 adds both legs, and 65 mixes the 240-volt load into the unbalance.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 220.61(A)

  10. A multiwire branch circuit's shared neutral runs through several receptacles in a daisy chain on a work wall. At each box the incoming and outgoing neutrals are landed on the two silver terminal screws of the receptacle, with no splice or pigtail. Which rule do the connections violate?

    Answer: 300.13(B), neutral continuity may not depend on devices

    300.13(B) says that in multiwire branch circuits, the continuity of a grounded conductor shall not depend on device connections such as receptacles or lampholders where removal of the device would interrupt the continuity. The neutral should be spliced with a pigtail to the device so that removing a receptacle leaves the neutral intact for the other circuit.

    Reference: NFPA 70, National Electrical Code (NEC), 2020 edition, 300.13(B)

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.