Requirements at a glance
| Agency | Your Nebraska city licenses you (IAPMO lists Grand Island for mechanical); IAPMO gives the exam |
|---|---|
| Experience | Set by your city (Nebraska has no state mechanical license) |
| Exam | 125 multiple-choice questions, 4 hours; pass mark not published |
| Books allowed | Original, bound Uniform Mechanical Code, 2021 edition (no loose papers or notes) |
| Fees | IAPMO exam fee (not published), plus your city's license fees |
Mechanical contractors and technicians applying to a Nebraska city that uses the IAPMO exam (IAPMO lists Grand Island) for a master mechanical license. Nebraska has no state mechanical license, so your city sets the experience rules.
How to get licensed, step by step
Get your city's approval
Ask your city which exam it uses and what experience it requires. IAPMO will not let you test without approval.
IAPMO: Nebraska plumbing license testing (opens in a new tab)
Register with IAPMO
Register for the exam on IAPMO's online proctored platform.
IAPMO: Nebraska plumbing license testing (opens in a new tab)
Take the exam
The exam is open book with your bound UMC. A code book from the wrong year is turned away.
IAPMO: Nebraska plumbing license testing (opens in a new tab)
Get licensed
Send your city your results and license fee.
IAPMO: Nebraska plumbing license testing (opens in a new tab)
How to prepare
- Nebraska has no state mechanical license: your city licenses you. IAPMO lists only Grand Island for the mechanical exams, and it tests the 2021 UMC. Get your city's approval and confirm the code year before you buy a book.
- IAPMO only admits an original, bound UMC whose edition matches the exam's code year, with no loose papers or notes in it. Our questions follow the 2021 UMC.
- Exhaust systems (Chapter 5) is the largest chapter, then combustion air (Chapter 7) and general regulations (Chapter 3). Tab the Chapter 7 and 8 sizing methods for the combustion air sizing and vent sizing sections.
- The master exam weights exhaust systems (17), combustion air (12) and specific appliances (11) more heavily than the journeyman exam. Practice combustion air and vent sizing too.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the UMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Uniform Mechanical Code (UMC), 2021 Edition, IAPMOEssential
Open book: an original bound copy. IAPMO requires the edition to match the exam's code year (2021).
IAPMO store (opens in a new tab)Read free: 2021 UMC (IAPMO) (opens in a new tab)
Official reference list (as published by the testing agency)
- Uniform Mechanical Code (UMC), 2021 edition (IAPMO): an original, bound copy whose edition matches the exam's code year
What's on the exam
Official content outline from IAPMO (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Chapter 2: Definitions | 7 | |
| Chapter 3: General Regulations | 11 | |
| Chapter 4: Ventilation Air | 7 | |
| Chapter 5: Exhaust Systems | 17 | |
| Chapter 6: Duct Systems | 8 | |
| Chapter 7: Combustion Air | 12 | |
| Chapter 8: Chimneys and Vents | 9 | |
| Chapter 9: Installation of Specific Appliances | 11 | |
| Chapter 10: Boilers and Pressure Vessels | 8 | |
| Chapter 11: Refrigeration | 8 | |
| Chapter 12: Hydronics | 7 | |
| Chapter 13: Fuel Gas Piping | 8 | |
| Chapter 17: Referenced Standards | 2 | |
| Combustion Air Sizing | 4 | |
| Vent Sizing | 6 |
Exam day details
- Administered by IAPMO for Nebraska cities (Grand Island, Kearney and others).
- Fee: Paid to IAPMO when you register (amount not published). Your city's license fees are separate.
- 125 multiple-choice questions in 4 hours (240 minutes).
- Open book: only an original, bound UMC (no photocopies) whose edition matches the exam's code year (2021). Loose papers or notes in the book end the exam and are reported.
- Online proctored through IAPMO. You need your city's approval before you register; IAPMO does not print the exam fee or pass mark.
- Nebraska has no state mechanical license. IAPMO lists only Grand Island for the mechanical exams. Our questions follow the 2021 UMC with no state amendments.
Note: IAPMO does not publish the pass mark or fee, and the city sets any local amendments.
Frequently asked questions
What's on the Nebraska master mechanical exam?
125 questions from the 2021 UMC: exhaust systems (Chapter 5) 17, combustion air (Chapter 7) 12, general regulations 11, installation of specific appliances 11, chimneys and vents 9, then smaller sections on every other chapter plus vent sizing (6) and combustion air sizing (4).
Which UMC edition does it use?
The 2021 Uniform Mechanical Code. IAPMO only admits an original, bound code book whose edition matches the exam's year.
Free questions with answers
Show all 10 free questions and answers
Under the UMC definitions, a Type II hood is used to collect and remove which of the following?
Answer: Steam, vapor, heat or odors
A Type I hood collects and removes grease and smoke, while a Type II (general kitchen) hood removes steam, vapor, heat or odors. Type I is the one used over grease-producing appliances.
Reference: 2021 Uniform Mechanical Code, Chapter 2, Section 210.0 (Hood, Type I and Type II)
A central heating boiler that is not listed for closet or alcove installation has a volume of 30 cubic feet. What is the minimum volume of the room in which it may be installed under the UMC?
Answer: 480 cubic feet
A boiler not listed for closet or alcove installation needs a room volume of at least 16 times the boiler volume: 16 x 30 = 480 cubic feet. The 12-times factor (360) applies to unlisted furnaces, not boilers. Ceiling height above 8 feet is calculated as 8 feet.
Reference: 2021 Uniform Mechanical Code, Section 303.2
A domestic clothes dryer exhaust duct will have four 90-degree elbows, and the dryer manufacturer gives no longer-length allowance. What is the maximum total combined horizontal and vertical duct length under the UMC?
Answer: 10 feet
The base limit is 14 feet including two 90-degree elbows, and 2 feet are deducted for each elbow in excess of two. Four elbows means two extra elbows, so 14 - 2 x 2 = 10 feet. Choosing 14 ignores the deduction, and 12 deducts for only one elbow.
Reference: 2021 Uniform Mechanical Code, Section 504.4.2.1
What is the maximum length of a flexible air duct run under the UMC, and may it replace rigid elbows and fittings?
Answer: 5 feet, and it may not be used in lieu of rigid elbows or fittings
Flexible air ducts may not be longer than 5 feet and may not be used in place of rigid elbows or fittings, although a flexible duct may serve as the elbow at a terminal device. They must also be listed to UL 181 and be installed using the minimum length needed to make the connection.
Reference: 2021 Uniform Mechanical Code, Section 603.4.1
Where indoor spaces on the same story are connected for combustion air, how must the two openings be located, and what is the smallest dimension allowed?
Answer: One within 12 inches of the top and one within 12 inches of the bottom, with a minimum dimension of 3 inches
One permanent opening must start within 12 inches of the top of the enclosure and one within 12 inches of the bottom. No air opening may have a dimension smaller than 3 inches. Each opening is sized at 1 square inch per 1,000 Btu/h but not less than 100 square inches.
Reference: 2021 Uniform Mechanical Code, Section 701.5(1)
A residential-type chimney passes through a flat roof, and a taller part of the building sits 8 feet away horizontally. What minimum termination height does the UMC require?
Answer: At least 3 feet above where it passes through the roof and at least 2 feet higher than that building portion
A chimney for residential-type or low-heat appliances must extend at least 3 feet above the highest point where it passes through the roof and at least 2 feet higher than any portion of a building within 10 horizontal feet. The building portion here is within 10 feet, so both limits apply, and the higher of the two governs.
Reference: 2021 Uniform Mechanical Code, Section 802.5.4
A central furnace is not covered by the listed or unlisted furnace supply duct provisions of Section 603.13. What clearance from combustibles applies to its supply ducts?
Answer: 18 inches for the first 3 feet from the plenum, 6 inches for the next 3 feet, then 1 inch beyond 6 feet
For central furnaces other than those in Sections 603.13.2 and 603.13.3, supply ducts need 18 inches of clearance from the furnace plenum for the first 3 feet, then 6 inches for the next 3 feet, and 1 inch beyond 6 feet from the plenum.
Reference: 2021 Uniform Mechanical Code, Section 904.2.7
What is the minimum unobstructed passageway width around all sides of an installed boiler, unless the AHJ allows a smaller side clearance?
Answer: 18 inches
Passageways around all sides of boilers must have an unobstructed width of at least 18 inches. With AHJ approval, boilers may be installed with less side clearance if the lesser clearance does not inhibit inspection, maintenance or repair.
Reference: 2021 Uniform Mechanical Code, Section 1010.1
What is the maximum total quantity of refrigerant that may be stored in a machinery room in containers that do not have relief valves and piping per Section 1113.0?
Answer: 330 pounds
The total refrigerant stored in a machinery room in containers without relief valves and piping must not exceed 330 pounds, and it must be in approved containers. More must be stored in an approved storage facility.
Reference: 2021 Uniform Mechanical Code, Section 1105.12.1
Piping for other than dry gas must be sloped to prevent traps. What minimum slope does the UMC state?
Answer: 1/4 inch in 15 feet
Gas piping for other than dry gas conditions must be sloped not less than 1/4 inch in 15 feet to prevent traps, so condensate drains back toward a drip or the source.
Reference: 2021 Uniform Mechanical Code, Section 1310.3.3
Sources
Questions last verified November 7, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.