Nebraska licensing exam

Nebraska Journeyman Mechanical Exam: Practice Test & Licensing Guide

The IAPMO exam used for a journeyman mechanical license in Grand Island, Nebraska: 100 multiple-choice questions on the 2021 Uniform Mechanical Code. Open book.

Questions
100
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Chapter 2: Definitions

A chimney is designed for residential-type appliances whose combustion gases do not exceed 1000 degrees F measured at the appliance flue outlet. Which UMC chimney classification is that?

Requirements at a glance

AgencyYour Nebraska city licenses you (IAPMO lists Grand Island for mechanical); IAPMO gives the exam
ExperienceSet by your city (Nebraska has no state mechanical license)
Exam100 multiple-choice questions, 3 hours; pass mark not published
Books allowedOriginal, bound Uniform Mechanical Code, 2021 edition (no loose papers or notes)
FeesIAPMO exam fee (not published), plus your city's license fees

Mechanical contractors and technicians applying to a Nebraska city that uses the IAPMO exam (IAPMO lists Grand Island) for a journeyman mechanical license. Nebraska has no state mechanical license, so your city sets the experience rules.

How to get licensed, step by step

  1. Get your city's approval

    Ask your city which exam it uses and what experience it requires. IAPMO will not let you test without approval.

    IAPMO: Nebraska plumbing license testing (opens in a new tab)

  2. Register with IAPMO

    Register for the exam on IAPMO's online proctored platform.

    IAPMO: Nebraska plumbing license testing (opens in a new tab)

  3. Take the exam

    The exam is open book with your bound UMC. A code book from the wrong year is turned away.

    IAPMO: Nebraska plumbing license testing (opens in a new tab)

  4. Get licensed

    Send your city your results and license fee.

    IAPMO: Nebraska plumbing license testing (opens in a new tab)

How to prepare

  • Nebraska has no state mechanical license: your city licenses you. IAPMO lists only Grand Island for the mechanical exams, and it tests the 2021 UMC. Get your city's approval and confirm the code year before you buy a book.
  • IAPMO only admits an original, bound UMC whose edition matches the exam's code year, with no loose papers or notes in it. Our questions follow the 2021 UMC.
  • Exhaust systems (Chapter 5) is the largest chapter, then combustion air (Chapter 7) and general regulations (Chapter 3). Tab the Chapter 7 and 8 sizing methods for the combustion air sizing and vent sizing sections.
  • Combustion air sizing (4) and vent sizing (6) are separate exam sections: practice working the Chapter 7 and Chapter 8 methods from a described appliance.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the UMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • Uniform Mechanical Code (UMC), 2021 edition (IAPMO): an original, bound copy whose edition matches the exam's code year

What's on the exam

Official content outline from IAPMO (number of questions per topic):

TopicQuestions
Chapter 2: Definitions6
Chapter 3: General Regulations11
Chapter 4: Ventilation Air6
Chapter 5: Exhaust Systems14
Chapter 6: Duct Systems6
Chapter 7: Combustion Air8
Chapter 8: Chimneys and Vents6
Chapter 9: Installation of Specific Appliances8
Chapter 10: Boilers and Pressure Vessels6
Chapter 11: Refrigeration6
Chapter 12: Hydronics5
Chapter 13: Fuel Gas Piping6
Chapter 17: Referenced Standards2
Combustion Air Sizing4
Vent Sizing6

Exam day details

  • Administered by IAPMO for Nebraska cities (Grand Island, Kearney and others).
  • Fee: Paid to IAPMO when you register (amount not published). Your city's license fees are separate.
  • 100 multiple-choice questions in 3 hours (180 minutes).
  • Open book: only an original, bound UMC (no photocopies) whose edition matches the exam's code year (2021). Loose papers or notes in the book end the exam and are reported.
  • Online proctored through IAPMO. You need your city's approval before you register; IAPMO does not print the exam fee or pass mark.
  • Nebraska has no state mechanical license. IAPMO lists only Grand Island for the mechanical exams. Our questions follow the 2021 UMC with no state amendments.

Note: IAPMO does not publish the pass mark or fee, and the city sets any local amendments.

Frequently asked questions

What's on the Nebraska journeyman mechanical exam?

100 questions from the 2021 UMC: exhaust systems (Chapter 5) 14, general regulations 11, combustion air (Chapter 7) 8, installation of specific appliances 8, then vent sizing and Chapter 8 chimneys and vents 6 each, and smaller sections on definitions, ventilation air, ducts, boilers, refrigeration, hydronics, fuel gas piping, combustion air sizing and referenced standards.

Which UMC edition does it use?

The 2021 Uniform Mechanical Code. IAPMO only admits an original, bound code book whose edition matches the exam's year.

Free questions with answers

Show all 10 free questions and answers
  1. A chimney is designed for residential-type appliances whose combustion gases do not exceed 1000 degrees F measured at the appliance flue outlet. Which UMC chimney classification is that?

    Answer: Residential appliance-type chimney

    A residential appliance-type chimney serves residential appliances with flue gases not above 1000 degrees F (538 C). A high-heat appliance-type chimney is for gases above 2000 degrees F (1093 C).

    Reference: 2021 Uniform Mechanical Code, Section 203.0 (Chimney, Residential Appliance-Type)

  2. A cooling system rated at 30 tons of refrigeration drains condensate from one coil to a single waste pipe. What is the minimum condensate waste pipe size per the UMC table?

    Answer: 1 inch

    Table 310.3 lists 21 to 40 tons at a 1 inch minimum. Up to 20 tons is 3/4 inch, and 41 to 90 tons is 1-1/4 inch. The table assumes a slope of 1/8 inch per foot.

    Reference: 2021 Uniform Mechanical Code, Table 310.3

  3. Required outdoor air intakes must be covered with a screen. What opening size range does the UMC allow for the screen?

    Answer: Not less than 1/4 inch and not more than 1/2 inch

    Section 402.4 calls for a screen with openings not smaller than 1/4 inch and not larger than 1/2 inch. Finer screens clog, and larger openings admit birds and debris.

    Reference: 2021 Uniform Mechanical Code, Section 402.4

  4. Unless the dryer manufacturer or AHJ allows otherwise, what is the maximum combined horizontal and vertical length of a domestic dryer exhaust duct including two 90 degree elbows?

    Answer: 14 feet

    Section 504.4.2.1 caps the duct at 14 feet total combined length including two 90 degree elbows. Extra elbows reduce the allowable length further.

    Reference: 2021 Uniform Mechanical Code, Section 504.4.2.1

  5. At what maximum intervals must horizontal runs and vertical risers of flexible air duct be supported?

    Answer: Horizontal runs 4 feet, vertical risers 6 feet

    The flexible air duct installation list requires horizontal runs supported at not more than 4 feet and vertical risers at not more than 6 feet. Supports must be rigid and at least 1-1/2 inches wide at the duct.

    Reference: 2021 Uniform Mechanical Code, Section 603.4

  6. When two rooms on the same story are connected by indoor openings to share combustion air volume, what is the minimum free area of each opening?

    Answer: 1 square inch per 1000 Btu/h but not less than 100 square inches

    Section 701.5(1) requires each opening to have at least 1 square inch per 1000 Btu/h of total input and not less than 100 square inches, one commencing within 12 inches of the top and one within 12 inches of the bottom of the enclosure.

    Reference: 2021 Uniform Mechanical Code, Section 701.5

  7. A chimney serves a medium-heat gas appliance. How high must it extend relative to nearby buildings?

    Answer: At least 10 feet above any portion of a building within 25 feet

    Section 802.5.4.1 requires medium-heat appliance chimneys to extend at least 10 feet higher than any portion of a building within 25 feet. The 3 foot and 2 foot rule applies to residential-type and low-heat chimneys.

    Reference: 2021 Uniform Mechanical Code, Section 802.5.4.1

  8. An unlisted central heating furnace's supply ducts (not covered by Section 603.13.2 or 603.13.3) need what clearances to combustibles measured from the furnace plenum?

    Answer: 18 inches for the first 3 feet, 6 inches for the next 3 feet, then 1 inch beyond 6 feet

    Section 904.2.7 sets 18 inches from the plenum for the first 3 feet, 6 inches for the next 3 feet and 1 inch beyond 6 feet. Mixing up the stepdown pattern is the common error.

    Reference: 2021 Uniform Mechanical Code, Section 904.2.7

  9. A closed-type expansion tank is installed on a hot water system. For what hydrostatic test pressure must the tank be designed?

    Answer: 2-1/2 times the allowable working pressure

    Section 1004.3 requires closed-type tanks to be designed for a hydrostatic test pressure of two and one-half times the allowable working pressure of the system, with ASME BPVC Section VIII applying for systems above 30 psi.

    Reference: 2021 Uniform Mechanical Code, Section 1004.3

  10. What size unobstructed opening and passageway must be maintained to a compressor or valve needing routine maintenance?

    Answer: 36 inches wide and 80 inches high

    Section 1105.3 requires an unobstructed readily accessible opening and passageway not less than 36 inches wide and 80 inches high to the compressor, required valves or other parts needing routine maintenance.

    Reference: 2021 Uniform Mechanical Code, Section 1105.3

Sources

Questions last verified November 7, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.