Requirements at a glance
| Agency | Mississippi State Board of Contractors (MSBOC); exams by PSI |
|---|---|
| License | Residential license (work over $10,000) |
| Exams | 80 questions, 4 hours, 70%, plus the Law and Business Management exam |
| Books allowed | 2021 IMC, 2018 Fuel Gas Code, Manual J, a ductulator, Modern Refrigeration and Air Conditioning, SMACNA and Residential Oil Burners |
| Fees | $120 per PSI exam portion (nonrefundable), plus the MSBOC application fee ($50 residential; $100 for each added classification) |
Qualifying individuals for a Mississippi residential HVAC license, which is part of the residential mechanical license with residential plumbing.
Official links
How to get licensed, step by step
Apply to the MSBOC
Send the application and fee to the Board. The firm names a qualifying individual who takes the exams.
MSBOC: contractor licenses (opens in a new tab)Mississippi State Board of Contractors (MSBOC) (opens in a new tab)
Schedule the Law and Business exam and the residential HVAC exam with PSI
After the Board approves you it notifies PSI. Book both exams ($120 per portion). You have 6 months from eligibility to pass, with unlimited retests in that window.
Schedule with PSI (Mississippi contractors) (opens in a new tab)PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)
Pass both exams at 70%
Both exams are open book and need 70% to pass.
PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)
Get licensed
The Board reviews applications weekly and issues the license in about 5 working days after approval. Licenses renew annually.
Mississippi State Board of Contractors (MSBOC) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's list: the 2020 NEC for electrical, the 2021 IPC, IMC and IFGC for commercial plumbing and mechanical, and the 2018 Fuel Gas Code with the 2021 IRC on the residential lists. Code questions use only the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight, underline and index them, but you can't write in them or add loose papers; sticky notes are removed.
- Mississippi licenses contractor firms, not individual tradespeople. These are the exams the firm's qualifying individual takes; journeyman and master cards are local.
- Ducts (14) is the biggest section; practice duct sizing with the ductulator and Manual J load calculations (6).
- Fuel gas, LP gas, fuel oil and piping together are 16 questions and use the 2018 IFGC.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IMC and the 2018 IFGC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 International Mechanical Code (IMC)Essential
Allowed in the exam room. The core of the mechanical, residential HVAC, refrigeration and boiler exams.
2018 International Fuel Gas Code (IFGC)Essential
PSI lists the 2018 edition for the residential plumbing and residential HVAC exams.
Modern Refrigeration and Air Conditioning, 22nd Edition (Goodheart-Willcox)
Allowed in the exam room. The 20th and 21st editions were dropped from PSI's list on 8/1/2026.
Official reference list (as published by the testing agency)
- 2021 International Mechanical Code (IMC)
- 2018 International Fuel Gas Code (IFGC)
- ACCA Manual J, a ductulator and Modern Refrigeration and Air Conditioning
- SMACNA (2020, 4th Edition) and Residential Oil Burners
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Insulation | 3 | |
| Hangers and Supports | 3 | |
| Sound Vibration and Seismic Control | 1 | |
| Heating and Cooling Principles | 6 | |
| Refrigerants | 4 | |
| Load Calculations | 6 | |
| Testing Adjusting and Balancing | 1 | |
| Controls | 4 | |
| A/C and Heat Pump Equipment | 6 | |
| Furnaces and Heaters | 5 | |
| Chimneys Flues and Vents | 3 | |
| Combustion Air | 3 | |
| Ducts | 14 | |
| Ventilation and Exhausts | 3 | |
| Safety | 2 | |
| Fuel Gas | 5 | |
| LP Gas | 4 | |
| Fuel Oil | 2 | |
| Piping | 5 |
Exam day details
- Administered by PSI Services for the Mississippi State Board of Contractors (MSBOC).
- Fee: $120 per exam portion to PSI, nonrefundable. MSBOC application and license fees are separate.
- 80 scored questions in 4 hours; 56 correct (70%) to pass. PSI adds about 10% unscored experimental items.
- Open book: bring only the exact editions on PSI's list for this exam. You may highlight, underline and index them with permanent tabs, but not write in them; sticky notes are removed. A silent, non-programmable calculator is allowed.
- After the MSBOC approves your application it notifies PSI, and you have 6 months from eligibility to pass; retests within that window are unlimited.
- Every Mississippi contractor license needs the Law and Business Management exam plus the trade exam for the classification.
- State-specific code rules override the national code, and code questions use only the listed edition.
Frequently asked questions
What's on the Mississippi Residential HVAC Exam?
80 scored questions: Ducts 14, heating and cooling principles 6, load calculations 6, a/c and heat pump equipment 6, furnaces and heaters 5, fuel gas 5, piping 5, refrigerants 4, controls 4, lp gas 4, insulation 3, hangers and supports 3, chimneys flues and vents 3, combustion air 3, ventilation and exhausts 3, safety 2, fuel oil 2, sound vibration and seismic control 1, testing adjusting and balancing 1.
Which books can I bring to the Mississippi Residential HVAC Exam?
The 2021 IMC, the 2018 IFGC, Manual J, a ductulator, Modern Refrigeration and Air Conditioning, SMACNA (2020, 4th Edition) and Residential Oil Burners.
Does Mississippi license individual tradespeople at the state level?
No. The MSBOC licenses contractor firms, and each firm names a qualifying individual who takes these exams. Journeyman and master cards are issued locally by cities.
Free questions with answers
Show all 10 free questions and answers
A flexible air connector (not a flexible air duct) is used to link a supply trunk to a ceiling diffuser in a house. Under IMC Section 603.6.2, what limits apply?
Answer: Maximum length of 14 feet, and it may not pass through a wall, floor or ceiling
IMC 603.6.2.1 limits flexible air connectors to 14 feet and 603.6.2.2 prohibits them from passing through any wall, floor or ceiling. Flexible air ducts (603.6.1.1) are a different product with no length limit, which is the usual source of confusion. Connectors must be listed Class 0 or Class 1.
Reference: 2021 International Mechanical Code, Sections 603.6.2.1 and 603.6.2.2
A low-pressure gas system in a house works at 0.5 psig (about 14 inches of water column). Under IFGC Section 406.4.1, what minimum test pressure applies?
Answer: 3 psig
1.5 x 0.5 = 0.75 psig, but 406.4.1 sets a minimum of 3 psig regardless of design pressure, so 3 psig governs. Choice 0.75 forgets the minimum.
Reference: 2018 International Fuel Gas Code, Section 406.4.1
Plastic pipe is proposed for an LP-gas yard line to a house. Under IFGC Section 404.17.1, what is the maximum operating pressure for plastic pipe carrying LP-gas, and where may it be installed?
Answer: 30 psig, outdoors underground only
Plastic pipe may be installed outdoors underground only, and operated at no more than 100 psig for natural gas or 30 psig for LP-gas. It is not allowed within or under a building or slab. The 100 psig figure is the natural gas limit.
Reference: 2018 International Fuel Gas Code, Section 404.17.1
A gas line to a furnace is run in smooth-wall copper tubing, 5/8 inch O.D., across the basement ceiling. Using IFGC Table 415.1, what is the maximum spacing between its supports?
Answer: 6 feet
The tubing columns of Table 415.1 give 4 feet for 1/2-inch O.D., 6 feet for 5/8- or 3/4-inch O.D., and 8 feet for 7/8- or 1-inch O.D. horizontal tubing, so the answer is 6 feet. 8 feet is the value for 3/4- or 1-inch steel pipe, and 10 feet is for horizontal steel pipe 1 1/4 inch and larger.
Reference: 2018 International Fuel Gas Code, Table 415.1
Which standard does IMC Section 1103.1 use to classify refrigerants by toxicity and flammability?
Answer: ASHRAE 34
1103.1 classifies refrigerants per ASHRAE 34 (Table 1103.1). ASME B31.5 is the refrigerant piping design standard cited in 1109.1, and UL 207 covers fittings.
Reference: 2021 International Mechanical Code, Section 1103.1
A gas-fired indoor air-conditioning appliance is being installed in a closet of a house. Which clearance rule applies to it under IFGC Section 308.3.1?
Answer: The manufacturer's installation instructions
IFGC 308.3.1 requires gas-fired air-conditioning appliances to be installed with clearances in accordance with the manufacturer's instructions; the code sets no flat inch figure. Reduced clearances to combustibles are allowed only with the protection of Table 308.2 and only where the manufacturer permits it (308.3.2). An all-electric heat pump air handler is outside the fuel gas code and follows IMC 304.1 and its listing instead.
Reference: 2018 International Fuel Gas Code, Sections 308.3.1 and 308.3.2
A volume damper is proposed in the air inlet to a furnace. What does IMC Section 918.3 say?
Answer: It may not be placed so it reduces required furnace air
Section 918.3 states volume dampers shall not be placed in the air inlet to a furnace in a manner that will reduce the required air to the furnace. Throttling the inlet could overheat the heat exchanger.
Reference: 2021 International Mechanical Code, Section 918.3
A residential air handler moves 1,400 cfm across a coil with an 18°F temperature difference. Using the sensible heat equation Q = 1.08 x cfm x TD, what is the sensible capacity?
Answer: 27,216 Btu/h
Q = 1.08 x 1,400 x 18 = 27,216 Btu/h. 25,200 drops the 1.08 factor, 30,240 uses 1.2 in place of 1.08, and 113,400 uses the 4.5 total-heat (enthalpy) factor, which belongs with an enthalpy difference, not a dry-bulb temperature difference.
Reference: General HVAC practice, Sensible heat equation (Q = 1.08 x cfm x TD)
A 200 square foot wall has an overall R-value of 13. Outdoor design temperature is 0°F and indoor is 50°F, so the temperature difference is 50°F. What is the conduction heat loss using Q = A x TD / R?
Answer: 769 Btu/h
Q = 200 x 50 / 13 = 769 Btu/h. 130,000 multiplies by R instead of dividing, 650 comes from 50 x 13, and 7,692 misplaces a decimal.
Reference: General HVAC practice, Conduction heat loss (Q = A x TD / R)
A supply duct attaches to a listed central heating furnace plenum. For what distance from the plenum must the duct keep the plenum's clearance to combustibles under IFGC Section 308.4.5?
Answer: 3 feet
308.4.5 requires supply ducts connecting to listed central heating furnaces to keep the same clearance to combustibles as the supply plenum for at least 3 feet from the plenum. No clearance is needed beyond that distance.
Reference: 2018 International Fuel Gas Code, Section 308.4.5
Sources
- PSI: Mississippi Contractors Candidate Information Bulletin (updated 11/11/2026) (opens in a new tab)
- Mississippi State Board of Contractors (MSBOC) (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.