Requirements at a glance
| Agency | Mississippi State Board of Contractors (MSBOC); exams by PSI |
|---|---|
| License | Commercial Certificate of Responsibility (projects of $50,000 or more) |
| Exams | 50 questions, 2 hours, 70%, plus the Law and Business Management exam |
| Books allowed | 2021 IMC, Industrial Refrigeration Handbook and Modern Refrigeration and Air Conditioning |
| Fees | $120 per PSI exam portion (nonrefundable), plus the MSBOC application fee ($400 commercial; $100 for each added classification) |
Qualifying individuals for a Mississippi unlimited commercial and industrial refrigeration contractor classification.
Official links
How to get licensed, step by step
Apply to the MSBOC
Send the application, fee and a CPA-reviewed financial statement to the Board. The firm names a qualifying individual who takes the exams.
MSBOC: contractor licenses (opens in a new tab)Mississippi State Board of Contractors (MSBOC) (opens in a new tab)
Schedule the Law and Business exam and the refrigeration exam with PSI
After the Board approves you it notifies PSI. Book both exams ($120 per portion). You have 6 months from eligibility to pass, with unlimited retests in that window.
Schedule with PSI (Mississippi contractors) (opens in a new tab)PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)
Pass both exams at 70%
Both exams are open book and need 70% to pass.
PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)
Get licensed
The Board reviews applications weekly and issues the license in about 5 working days after approval. Licenses renew annually.
Mississippi State Board of Contractors (MSBOC) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's list: the 2020 NEC for electrical, the 2021 IPC, IMC and IFGC for commercial plumbing and mechanical, and the 2018 Fuel Gas Code with the 2021 IRC on the residential lists. Code questions use only the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight, underline and index them, but you can't write in them or add loose papers; sticky notes are removed.
- Mississippi licenses contractor firms, not individual tradespeople. These are the exams the firm's qualifying individual takes; journeyman and master cards are local.
- Refrigeration and refrigerants (15) and components (10) are half of the exam. Know the cycle, superheat and subcooling.
- Tab IMC Chapter 11: refrigerant classification, machinery rooms, piping and testing.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 International Mechanical Code (IMC)Essential
Allowed in the exam room. The core of the mechanical, residential HVAC, refrigeration and boiler exams.
Modern Refrigeration and Air Conditioning, 22nd Edition (Goodheart-Willcox)
Allowed in the exam room. The 20th and 21st editions were dropped from PSI's list on 8/1/2026.
Official reference list (as published by the testing agency)
- 2021 International Mechanical Code (IMC)
- Industrial Refrigeration Handbook (Stoecker, 1995)
- Modern Refrigeration and Air Conditioning, 22nd Edition (20th and 21st dropped from the list 8/1/2026)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Refrigeration and Refrigerants | 15 | |
| Piping and Tubing | 6 | |
| Components | 10 | |
| Controls Valves and Wiring | 9 | |
| Tests Inspections and Maintenance | 6 | |
| Safety | 4 |
Exam day details
- Administered by PSI Services for the Mississippi State Board of Contractors (MSBOC).
- Fee: $120 per exam portion to PSI, nonrefundable. MSBOC application and license fees are separate.
- 50 scored questions in 2 hours; 35 correct (70%) to pass. PSI adds about 10% unscored experimental items.
- Open book: bring only the exact editions on PSI's list for this exam. You may highlight, underline and index them with permanent tabs, but not write in them; sticky notes are removed. A silent, non-programmable calculator is allowed.
- After the MSBOC approves your application it notifies PSI, and you have 6 months from eligibility to pass; retests within that window are unlimited.
- Every Mississippi contractor license needs the Law and Business Management exam plus the trade exam for the classification.
- State-specific code rules override the national code, and code questions use only the listed edition.
Frequently asked questions
What's on the Mississippi Refrigeration Exam?
50 scored questions: Refrigeration and Refrigerants 15, components 10, controls valves and wiring 9, piping and tubing 6, tests inspections and maintenance 6, safety 4.
Which books can I bring to the Mississippi Refrigeration Exam?
The 2021 IMC, the Industrial Refrigeration Handbook (Stoecker, 1995) and Modern Refrigeration and Air Conditioning.
Does Mississippi license individual tradespeople at the state level?
No. The MSBOC licenses contractor firms, and each firm names a qualifying individual who takes these exams. Journeyman and master cards are issued locally by cities.
Free questions with answers
Show all 10 free questions and answers
On a walk-in cooler, a technician measures 47°F on the suction line at the evaporator outlet. The suction gauge pressure corresponds to a saturated evaporating temperature of 34°F. What is the evaporator superheat?
Answer: 13°F
Superheat is the measured vapor temperature minus the saturation temperature at the same pressure: 47°F - 34°F = 13°F. Subtracting 32 gives 15°F (not meaningful here), 47°F is just the line temperature, and 81°F comes from adding the two readings.
Reference: General refrigeration practice, Concept: superheat calculation
On a reach-in freezer condensing unit, the high-side gauge corresponds to a saturated condensing temperature of 118°F and the liquid line temperature at the condenser outlet is 104°F. What is the subcooling?
Answer: 14°F
Subcooling is the saturation (condensing) temperature minus the actual liquid temperature: 118°F - 104°F = 14°F. Adding the readings gives 222°F, 104°F is only the liquid line temperature, and 24°F is a subtraction error.
Reference: General refrigeration practice, Concept: subcooling calculation
Which standard does IMC Section 1107.1 point to for piping materials and installation in R-717 (ammonia) systems?
Answer: IIAR 2
Section 1107.1 states that Section 1107 applies to refrigerants other than ammonia and that R-717 piping material and installation must comply with IIAR 2. ASTM B280 is a copper tube standard and UL 207 covers refrigerant fittings.
Reference: 2021 International Mechanical Code, Section 1107.1
A designer wants soldered joints on a refrigerant line. Under IMC Section 1108.3.3, which condition must be met?
Answer: Group A1 refrigerant at 200 psi or less
Section 1108.3.3 limits solder joints to refrigerant systems using Group A1 refrigerant at pressures less than or equal to 200 psi. Brazing is needed for higher pressures or other groups.
Reference: 2021 International Mechanical Code, Section 1108.3.3
Where is the sensing bulb of a thermostatic expansion valve normally attached?
Answer: To the suction line near the evaporator outlet
The bulb senses suction vapor temperature at the evaporator outlet. The valve compares that temperature with evaporator pressure to hold a set superheat. A bulb anywhere else would not measure the superheat the valve is meant to control.
Reference: General refrigeration practice, Concept: thermostatic expansion valve bulb
A TXV bulb is being clamped to a horizontal 1-1/8 inch O.D. suction line. Which position is the accepted practice?
Answer: About the 4 o'clock or 8 o'clock position on the tube
On lines 7/8 inch O.D. and larger, bulbs are placed at roughly 4 or 8 o'clock to avoid sensing oil that lies in the bottom of the line while still reading the tube wall temperature. On smaller lines the 10 or 2 o'clock position is commonly used. The bulb must be clamped tightly and insulated.
Reference: General refrigeration practice, Concept: TXV bulb mounting
In a pump-down refrigeration circuit with a liquid-line solenoid valve, what stops the compressor when the thermostat is satisfied?
Answer: The low-pressure control opens as suction pressure falls
When the thermostat is satisfied it de-energizes the liquid solenoid. The compressor keeps running and pumps the evaporator down until suction pressure drops to the low-pressure control's cut-out setting, which opens the contactor circuit. This keeps liquid out of the evaporator during the off cycle.
Reference: General refrigeration practice, Concept: pump-down control
An evaporator pressure regulating (EPR) valve is installed in a suction line. What does it do?
Answer: Holds the evaporator pressure from dropping below a set value
An EPR valve is placed at the evaporator outlet and throttles to keep the coil from running colder than its setting, which protects products such as produce from freezing on a multi-temperature rack. A crankcase pressure regulator, by contrast, limits suction pressure at the compressor.
Reference: General refrigeration practice, Concept: evaporator pressure regulator
Field-erected tubing not over 5/8 inch O.D. is being pressure tested. Under IMC Section 1110.3, what other test medium is allowed besides an inert gas?
Answer: The refrigerant on the equipment nameplate
Section 1110.3 permits systems erected on the premises with tubing of 5/8 inch O.D. or less to use the refrigerant named on the nameplate or marking as the test medium. Oxygen, air, combustible gases and mixtures containing them are not allowed.
Reference: 2021 International Mechanical Code, Section 1110.3
Before servicing the electrical components of a compressor, what should a technician do first?
Answer: Open and lock out the disconnect, then verify with a meter
Lockout and tagout of the disconnect, followed by checking that voltage is zero, protects against energization. A thermostat or contactor off position does not isolate the supply, and capacitors must be discharged as well.
Reference: General refrigeration practice, Concept: lockout and tagout
Sources
- PSI: Mississippi Contractors Candidate Information Bulletin (updated 11/11/2026) (opens in a new tab)
- Mississippi State Board of Contractors (MSBOC) (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.