Requirements at a glance
| Agency | Minnesota Department of Labor and Industry (DLI); Board of Electricity sets the rules |
|---|---|
| Experience | 60 months of experience (12 of them installing), or an electrical engineering degree, or 1 year as a journeyworker |
| Exam | 80 questions, 5.5 hours, 70% to pass |
| Books allowed | None of your own: DLI supplies the 2026 NEC (without tabs), the laws-and-rules booklet and a calculator |
| Fees | $50 per personal-license exam (Minn. Stat. 326B.092), plus application and license fees |
Electricians applying to DLI for a Class A master license after 60 months of experience (12 months installing), an electrical engineering degree, or 1 year as a journeyworker.
Official links
How to get licensed, step by step
Apply to DLI
Send DLI your Class A master application, proof of experience and the $50 exam fee. Journeyworkers with 1 year of licensed experience can apply.
Minnesota Department of Labor and Industry (DLI) (opens in a new tab)DLI: electrical license basics (opens in a new tab)
Schedule your exam
After DLI approves your application, you schedule the exam in DLI's iMS system. DLI gives exams at its St. Paul office (Tuesday to Thursday) and at outstate sites including Duluth, Mankato, Rochester and St. Cloud.
Take the exam
You have 5.5 hours and need 70%. The exam is open book with DLI-supplied references; no personal books, notes or electronic devices.
DLI: electrical license basics (opens in a new tab)DLI: electrical code and 2026 NEC fact sheet (opens in a new tab)
Results and retakes
DLI mails results in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
How to prepare
- Exams from September 8, 2026 are based on the 2026 NEC, adopted in Minnesota without amendments. Our questions follow the 2026 NEC and cite the 2026 article number where one moved.
- DLI's Electrical License Examination Guide gives 80 questions and lists the knowledge areas by NEC chapter but no weights, so our topic split is an estimate. Expect the NEC from Article 90 through the whole code plus applied electrical theory.
- Every DLI exam is open book, but with DLI-supplied references only: a code book without tabs, the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, so practice finding answers fast rather than relying on tabs.
- DLI publishes no topic weights, so our topic split is an estimate. Several versions of each exam are in use, and some questions ask for more than one answer or the choice that does not apply.
- Master questions lean on load calculations, service and feeder sizing and Minnesota Statutes 326B and Rules 3800: know licensing classes, the master's responsibilities and permit and inspection rules.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2026 EditionEssential
DLI supplies the code book in the exam room. Exams from September 8, 2026 are based on the 2026 NEC, adopted in Minnesota without amendments.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2026 edition. Minnesota exams are based on the 2026 NEC from September 8, 2026; it is adopted without Minnesota amendments (DLI supplies the code book).
- Minnesota Statutes 326B.31 to 326B.399 and Minnesota Rules chapters 3800 and 3801 (in the DLI laws-and-rules booklet)
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Electrical Theory and Calculations | 10 | |
| General Requirements and Definitions (NEC Articles 90 to 110) | 8 | |
| Wiring and Protection (NEC Chapter 2) | 18 | |
| Wiring Methods and Materials (NEC Chapter 3) | 14 | |
| Equipment for General Use (NEC Chapter 4) | 14 | |
| Special Occupancies, Equipment and Conditions (NEC Chapters 5 to 7) | 14 | |
| Communications Systems (NEC Chapter 8) | 4 | |
| Minnesota Statutes 326B and Rules 3800 | 18 |
Exam day details
- Administered by the Minnesota Department of Labor and Industry (DLI), which gives its own exams.
- Fee: $50 per personal-license exam (Minn. Stat. 326B.092). Application and license fees are separate.
- 5.5 hours, open book with DLI-supplied references; 70% to pass. DLI's Electrical License Examination Guide gives 80 questions.
- Open book with DLI-supplied references: you get the code book (without tabs), the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, notes or electronic devices.
- DLI gives the exam at its St. Paul office and outstate sites, scheduled after DLI approves your application. The time limit is 5.5 hours; the passing score is 70%.
- Results are mailed in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
- Some questions ask you to pick more than one answer (the question says how many) or the one choice that does not apply. Several versions of each exam are in use.
- DLI's Electrical License Examination Guide gives 80 questions for both the journeyworker and master exams and lists the knowledge areas by NEC chapter, but it publishes no topic weights, so our topic split is an estimate.
- Our questions follow the 2026 NEC. We could not read the 2026 NEC text, so questions use rules confirmed unchanged from 2023 or confirmed in published change lists; check article numbers in the code book DLI provides.
Note: DLI's Electrical License Examination Guide gives the question count (80) and a knowledge-area outline but no topic weights, so our topic weights here are estimates. Exams from September 8, 2026 use the 2026 NEC; we could not read the NFPA 2026 text, so confirm article numbers in the code book DLI provides.
Frequently asked questions
How is the master exam different from the journeyworker exam?
Third-party sources rate it harder (2.5 to 3.5 against 1.5 to 2.5). Expect more load calculations, service and feeder sizing and Minnesota law and rule questions.
Which NEC edition is tested?
The 2026 NEC, adopted in Minnesota without amendments, for exams from September 8, 2026.
How much does the exam cost?
The DLI exam fee is $50 (Minn. Stat. 326B.092). Application and license fees are separate.
Free questions with answers
Show all 10 free questions and answers
A 240-volt heating element has a resistance of 12 ohms. What current does it draw?
Answer: 20 amperes
Ohm's law: I = E / R = 240 / 12 = 20 A. 2,880 is E x R, 0.05 is R / E inverted, and 252 adds the two numbers.
Reference: Basic electrical theory, Ohm's law
A 277/480-volt (277 volts to ground) switchboard has exposed live parts on the front and a grounded concrete wall on the opposite side of the working space. What is the minimum working space depth?
Answer: 3-1/2 feet
Table 110.26(A)(1): for 151 to 600 volts to ground, Condition 2 (exposed live parts on one side and grounded parts on the other, including concrete, brick or tile walls) requires 3-1/2 ft. 3 ft is Condition 1 (no live or grounded parts opposite) and 4 ft is Condition 3 (live parts on both sides).
Reference: 2026 NEC (NFPA 70), Table 110.26(A)(1)
A branch circuit supplies a 24-ampere continuous load and an 8-ampere noncontinuous load. What is the minimum conductor ampacity before any adjustment or correction factors?
Answer: 38 amperes
Section 210.19(A)(1): minimum ampacity = 125 percent of the continuous load plus 100 percent of the noncontinuous load = (24 x 1.25) + 8 = 30 + 8 = 38 A. 32 A adds the loads without the 125 percent, 40 A applies 125 percent to everything (32 x 1.25), and 30 A ignores the noncontinuous load.
Reference: 2026 NEC (NFPA 70), Section 210.19(A)(1)
A 125-ampere noncontinuous load is fed by copper THHN conductors terminating on equipment with 75 degrees C terminations. What is the smallest conductor size permitted?
Answer: 1 AWG
Terminations of circuits over 100 A are evaluated at the 75 degrees C column (110.14(C)(1)(b)). In Table 310.16 at 75 degrees C, 1 AWG copper is 130 A, while 2 AWG is only 115 A. 2 AWG would be accepted only by using its 90 degrees C value of 130 A, which the termination does not allow. 1/0 AWG (150 A) is larger than needed.
Reference: 2026 NEC (NFPA 70), Table 310.16 and Section 110.14(C)(1)(b)
What is the minimum cover for Schedule 40 PVC conduit buried under a lawn, for a general installation (not a GFCI-protected 120-volt residential branch circuit)?
Answer: 18 inches
The minimum cover table for underground installations (Table 300.5 in 2023, moved to 300.7 in the 2026 NEC, as the Minnesota DLI 2026 inspection checklist shows) requires 18 in. for nonmetallic raceways listed for direct burial without concrete encasement. Rigid metal conduit needs only 6 in. Direct-buried cables require 24 in., and 12 in. is the reduced cover for 120-volt residential branch circuits rated 20 A or less with GFCI protection at the source.
Reference: 2026 NEC (NFPA 70), Section 300.7 minimum cover table (Table 300.5 in the 2023 NEC; Article 300 renumbered in 2026)
A 25-horsepower, 460-volt, 3-phase squirrel-cage motor (full-load current 34 A from Table 430.250) is protected by an inverse-time circuit breaker. Applying the Table 430.52(C)(1) percentage and the rule permitting the next higher standard rating when the result is not a standard size, what is the maximum breaker rating?
Answer: 90 amperes
Table 430.52(C)(1) permits an inverse-time breaker up to 250 percent of the full-load current: 34 x 2.5 = 85 A. Because 85 A is not a standard rating, 430.52(C)(1) permits the next higher standard rating from 240.6(A), which is 90 A. 80 A rounds down, 70 A is near 200 percent (68 A), and 100 A skips past the next standard size.
Reference: 2026 NEC (NFPA 70), Section 430.52(C)(1), Table 430.52(C)(1), Section 240.6(A)
Which wiring method is permitted in a Class I, Division 1 location without special permission?
Answer: Threaded rigid metal conduit or threaded intermediate metal conduit
Section 501.10(B)(1) allows threaded rigid metal conduit, threaded steel intermediate metal conduit, and in some cases Type MI, MC-HL and PLTC cable with listed fittings. EMT and NM cable are wiring methods for ordinary locations. Threaded fittings ensure explosionproof joints.
Reference: 2026 NEC (NFPA 70), Section 501.10(B)(1)
An aluminum bonding conductor for a receiving-station antenna is run outside to the grounding electrode. What is the closest it may be installed to the earth?
Answer: 18 inches above the earth
The Article 810 bonding rules permit aluminum or copper-clad aluminum bonding conductors, but they may not be used where in direct contact with masonry or the earth or where subject to corrosive conditions. If installed outside, they may not be within 18 in. of the earth. Copper is acceptable for direct burial and does not have this restriction. (This is 810.21(A) in the 2023 NEC; because the 2026 NEC reorganizes Chapter 8, the rule is cited by heading.)
Reference: 2026 NEC (NFPA 70), Article 810, receiving equipment, bonding conductors and grounding electrode conductors, material (810.21(A) in the 2023 NEC)
Which of the following satisfies the experience route for a Class A master electrician license, in addition to passing the examination?
Answer: At least one year of acceptable experience as a licensed journeyworker electrician
Minn. Stat. 326B.33, subd. 1, clause (1) lets an applicant qualify with a four-year electrical degree, or at least one year of acceptable experience as a licensed journeyworker, or at least five years of acceptable experience in planning, laying out, supervising and installing electrical work. Six months and a two-year course alone do not qualify.
Reference: Minnesota Statutes chapter 326B, Minn. Stat. 326B.33, subd. 1, clause (1)
Under the experience schedule for a Class A master electrician, what is the minimum total experience and the minimum amount that must be in wiring for and installing electrical wiring, apparatus and equipment?
Answer: 60 months total, with at least 12 months installing
Minn. R. 3800.3520, subp. 5(A) sets the Class A master minimum at 60 months total, including at least 12 months of wiring for and installing (maximum credit 48 months), and at least 2 months each in planning, laying out and supervising. 48 months is the journeyworker total (subp. 5(B)).
Reference: Minnesota Rules chapter 3800, Minn. R. 3800.3520, subp. 5(A)
Sources
- DLI Electrical License Examination Guide (opens in a new tab)
- Minnesota DLI: electrical license basics (opens in a new tab)
- Minnesota DLI: electrical code (2026 NEC fact sheet) (opens in a new tab)
- Minnesota DLI: license exam schedule (opens in a new tab)
Questions last verified November 9, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.