Requirements at a glance
| Agency | Minnesota Department of Labor and Industry (DLI); Board of Electricity sets the rules |
|---|---|
| Experience | 48 months of experience, 24 of them wiring or installing |
| Exam | 80 questions, 5.5 hours, 70% to pass |
| Books allowed | None of your own: DLI supplies the 2026 NEC (without tabs), the laws-and-rules booklet and a calculator |
| Fees | $50 per personal-license exam (Minn. Stat. 326B.092), plus application and license fees |
Electricians applying to DLI for a Class A journeyworker license after 48 months of experience (24 months of it wiring or installing).
Official links
How to get licensed, step by step
Apply to DLI
Send DLI your Class A journeyworker application, proof of experience and the $50 exam fee. Registered unlicensed individuals can register with DLI for a $14 fee.
Minnesota Department of Labor and Industry (DLI) (opens in a new tab)DLI: electrical license basics (opens in a new tab)
Schedule your exam
After DLI approves your application, you schedule the exam in DLI's iMS system. DLI gives exams at its St. Paul office (Tuesday to Thursday) and at outstate sites including Duluth, Mankato, Rochester and St. Cloud.
Take the exam
You have 5.5 hours and need 70%. The exam is open book with DLI-supplied references; no personal books, notes or electronic devices.
DLI: electrical license basics (opens in a new tab)DLI: electrical code and 2026 NEC fact sheet (opens in a new tab)
Results and retakes
DLI mails results in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
How to prepare
- Exams from September 8, 2026 are based on the 2026 NEC, adopted in Minnesota without amendments. Our questions follow the 2026 NEC and cite the 2026 article number where one moved.
- DLI's Electrical License Examination Guide gives 80 questions and lists the knowledge areas by NEC chapter but no weights, so our topic split is an estimate. Expect the NEC from Article 90 through the whole code plus applied electrical theory.
- Every DLI exam is open book, but with DLI-supplied references only: a code book without tabs, the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, so practice finding answers fast rather than relying on tabs.
- DLI publishes no topic weights, so our topic split is an estimate. Several versions of each exam are in use, and some questions ask for more than one answer or the choice that does not apply.
- Wiring methods and materials (Chapter 3) and wiring and protection (Chapter 2) are the biggest areas in our split: drill ampacity, box and raceway fill, overcurrent protection and grounding.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2026 EditionEssential
DLI supplies the code book in the exam room. Exams from September 8, 2026 are based on the 2026 NEC, adopted in Minnesota without amendments.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2026 edition. Minnesota exams are based on the 2026 NEC from September 8, 2026; it is adopted without Minnesota amendments (DLI supplies the code book).
- Minnesota Statutes 326B.31 to 326B.399 and Minnesota Rules chapters 3800 and 3801 (in the DLI laws-and-rules booklet)
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Electrical Theory and Calculations | 10 | |
| General Requirements and Definitions (NEC Articles 90 to 110) | 8 | |
| Wiring and Protection (NEC Chapter 2) | 18 | |
| Wiring Methods and Materials (NEC Chapter 3) | 18 | |
| Equipment for General Use (NEC Chapter 4) | 14 | |
| Special Occupancies, Equipment and Conditions (NEC Chapters 5 to 7) | 12 | |
| Communications Systems (NEC Chapter 8) | 4 | |
| Minnesota Statutes 326B and Rules 3800 | 16 |
Exam day details
- Administered by the Minnesota Department of Labor and Industry (DLI), which gives its own exams.
- Fee: $50 per personal-license exam (Minn. Stat. 326B.092). Application and license fees are separate.
- 5.5 hours, open book with DLI-supplied references; 70% to pass. DLI's Electrical License Examination Guide gives 80 questions.
- Open book with DLI-supplied references: you get the code book (without tabs), the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, notes or electronic devices.
- DLI gives the exam at its St. Paul office and outstate sites, scheduled after DLI approves your application. The time limit is 5.5 hours; the passing score is 70%.
- Results are mailed in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
- Some questions ask you to pick more than one answer (the question says how many) or the one choice that does not apply. Several versions of each exam are in use.
- DLI's Electrical License Examination Guide gives 80 questions for both the journeyworker and master exams and lists the knowledge areas by NEC chapter, but it publishes no topic weights, so our topic split is an estimate.
- Our questions follow the 2026 NEC. We could not read the 2026 NEC text, so questions use rules confirmed unchanged from 2023 or confirmed in published change lists; check article numbers in the code book DLI provides.
Note: DLI's Electrical License Examination Guide gives the question count (80) and a knowledge-area outline but no topic weights, so our topic weights here are estimates. Exams from September 8, 2026 use the 2026 NEC; we could not read the NFPA 2026 text, so confirm article numbers in the code book DLI provides.
Frequently asked questions
Which NEC edition is on the Minnesota journeyworker exam?
The 2026 NEC, for exams given from September 8, 2026. Minnesota adopted it without amendments.
Can I bring my own code book?
No. DLI supplies the code book (without tabs), the laws-and-rules booklet and a calculator for the whole exam.
What if I fail?
Wait 30 days after you receive your results, then reapply. Results come by mail in about 2 weeks.
Free questions with answers
Show all 10 free questions and answers
What is the minimum total experience, acceptable to the commissioner, that an applicant needs to sit for the Class A journeyworker electrician license?
Answer: Four years (48 months) of wiring for, installing and repairing electrical equipment
Section 326B.33, subd. 2(b) requires at least four years of experience in wiring for, installing and repairing electrical wiring, apparatus or equipment; Rule 3800.3520, subp. 5, item B shows the 48-month minimum. Five years with planning, layout and supervision is the Class A master path. One year of credit may be allowed for an approved two-year post-high-school electrical course.
Reference: Minnesota Statutes 326B.33, Subd. 2(b); Minn. R. 3800.3520, subp. 5(B)
Under Rule 3800.3520, subp. 5, how many of a Class A journeyworker applicant's 48 months must be spent specifically wiring for and installing electrical wiring, apparatus and equipment?
Answer: At least 24 months
Subp. 5, item B(4) sets a minimum of 24 months in wiring for and installing, with a maximum credit allowance of 48 months. The master electrician schedule (item A) is the one that requires 12 months in that category, plus 2 months each in planning, layout and supervising.
Reference: Minnesota Rules 3800, 3800.3520, subp. 5(B)(4)
A resistive load draws 12 amperes when connected to a 240-volt supply. What is its resistance?
Answer: 20 ohms
Ohm's law: R = E / I = 240 V / 12 A = 20 ohms. Multiplying volts by amperes gives 2,880, which is watts, not ohms; inverting the formula gives 0.05; adding the values is meaningless.
Reference: Basic electrical theory (Ohm's law), E = I x R
A 480Y/277-volt panelboard has exposed live parts on one side of its working space and a grounded concrete wall on the opposite side (Condition 2). What is the minimum depth of working space in front of the panel?
Answer: 3 ft 6 in.
The voltage to ground on a 480Y/277 system is 277 V, which falls in the 151-600 V row of Table 110.26(A)(1). Condition 2 (live parts on one side, grounded parts, including concrete, on the other) requires 1.0 m (3 ft 6 in.). 3 ft is the Condition 1 value, 4 ft is Condition 3, and 5 ft applies only to 601-1000 V Condition 3.
Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), Table 110.26(A)(1)
A branch circuit serves 12 amperes of continuous load and 5 amperes of noncontinuous load, using an overcurrent device not listed for operation at 100 percent. What is the minimum rating of the overcurrent device?
Answer: 20 amperes
Section 210.20(A): the overcurrent device must be at least the noncontinuous load plus 125 percent of the continuous load. 12 A x 1.25 = 15 A; 15 + 5 = 20 A. Adding the loads without the 125 percent (17 A) or sizing only to the continuous load (15 A) is undersized; 30 A is larger than needed.
Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), Section 210.20(A)
Six current-carrying 10 AWG copper THHN conductors are installed together in a conduit more than 24 in. long. Using the 90 degrees C ampacity of 40 amperes from Table 310.16, what is the adjusted ampacity?
Answer: 32 amperes
Table 310.15(C)(1) gives 80 percent for 4 to 6 current-carrying conductors: 40 A x 0.80 = 32 A. No adjustment (40 A) is wrong because more than three conductors are carrying current; 70 percent (28 A) applies to 7 to 9 conductors, and 50 percent (20 A) to 10 to 20.
Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), Section 310.14(C); Table 310.15(C)(1)
What is the maximum total bend allowed in an EMT run between pull points, such as between boxes?
Answer: 360 degrees, the equivalent of four quarter bends
Section 358.26 limits EMT to not more than the equivalent of four quarter bends (360 degrees total), including bends at offsets and any located immediately at the box, between pull points. The same 360-degree limit appears for RMC, IMC and FMC. Adding more bends makes pulling conductors damage the insulation.
Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), Section 358.26
A 15 horsepower, 230-volt, three-phase squirrel-cage motor (table full-load current 42 amperes) is protected by an inverse-time circuit breaker. What is the maximum rating that may be used for short-circuit and ground-fault protection, using the standard-size allowance?
Answer: 110 amperes
Table 430.52(C)(1) allows an inverse-time breaker at 250 percent of full-load current: 42 A x 2.5 = 105 A. Section 430.52(C)(1)(a) permits the next higher standard rating in 240.6(A) when the value does not match a standard size; the next standard size above 105 A is 110 A. 100 A is lower than allowed but not the maximum, 105 A is not a standard size, and 125 A is too high without the further increases of 430.52(C)(1)(b) for motors that will not start.
Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), Section 430.52(C)(1)(a); Table 430.52(C)(1); Section 240.6(A)
Which location is a Class I, Division 1 location?
Answer: One where ignitible concentrations of flammable gases or vapors can exist under normal operating conditions
Section 500.5(B)(1) classifies a Class I, Division 1 location as one where ignitible concentrations of flammable gases, flammable liquid-produced vapors or combustible liquid-produced vapors can exist under normal operating conditions, or frequently because of repair, maintenance or leakage, or where equipment failure could release them and also cause ignition. The ruptured-container condition describes Division 2. Fibers and dusts belong to Class III and Class II.
Reference: NFPA 70, National Electrical Code (2026 edition; requirement carried from the 2023 text), Section 500.5(B)(1)
What is the minimum size of a communications primary protector bonding conductor or grounding electrode conductor?
Answer: 14 AWG copper
The communications bonding conductor or grounding electrode conductor for a primary protector (800.100(A)(3) in the 2023 NEC; the 2026 edition reorganized Chapter 8, so the section number may differ) must not be smaller than 14 AWG copper and must have a current-carrying capacity not less than the grounded metallic sheath and protected conductors of the cable. It is not required to exceed 6 AWG.
Reference: NFPA 70, National Electrical Code (2026 edition; rule carried from the 2023 text; Chapter 8 communications provisions reorganized in 2026), Communications circuits, grounding methods: primary protector bonding conductor or grounding electrode conductor size (800.100(A)(3) in the 2023 NEC)
Sources
- DLI Electrical License Examination Guide (opens in a new tab)
- Minnesota DLI: electrical license basics (opens in a new tab)
- Minnesota DLI: electrical code (2026 NEC fact sheet) (opens in a new tab)
- Minnesota DLI: license exam schedule (opens in a new tab)
Questions last verified November 9, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.