Massachusetts licensing exam

Massachusetts Journeyperson Sheet Metal Exam (J-1 Unrestricted): Practice Test & Licensing Guide

The Massachusetts unrestricted journeyperson (J-1) sheet metal exam: 80 questions in 150 minutes on layout, duct sizing and fabrication, kitchen exhaust, life safety ventilation, welding, safety and 271 CMR. Open book, 70% to pass.

Questions
80
Time limit
2.5 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge

Under 271 CMR 2.01, which statement correctly separates a journeyperson sheet metal worker from a master?

Requirements at a glance

AgencyBoard of Examiners of Sheet Metal Workers (Division of Professional Licensure); exams by PSI
LicenseUnrestricted Journeyperson Sheet Metal (J-1)
Format80 questions, 150 minutes, open book, 70% to pass
Fees$180 to PSI, plus $155 application and initial license fee to the Commonwealth

Sheet metal apprentices applying for an Unrestricted Journeyperson Sheet Metal license from the Massachusetts Board of Examiners of Sheet Metal Workers.

How to get licensed, step by step

  1. Apply to the Board

    Submit the application with proof of your apprenticeship experience and education, and pay the application and initial license fee. Allow about 3 weeks for processing; PSI then emails your exam authorization.

    Board of Examiners of Sheet Metal Workers (opens in a new tab)

  2. Schedule the journeyperson sheet metal exam with PSI

    Schedule online or at (855) 746-8173. Cancel at least 2 days ahead or you forfeit your fees.

    Schedule with PSI (Massachusetts sheet metal workers) (opens in a new tab)

  3. Pass at 70%

    Bring your own copies of the allowed references, with permanent tabs only. If you fail, retake within 6 months of approval; after three failed attempts the Board wants proof of added study.

    Schedule with PSI (Massachusetts sheet metal workers) (opens in a new tab)

How to prepare

  • Layout (12), general knowledge (8), safety (8) and duct sizing, design, hangers and supports (8) are 36 of 80 questions.
  • Allowed in the room: the 2009 IMC, NFPA 96, 90A, 90B, 92A and 92B, both SMACNA manuals and 271 CMR. OSHA 1926 and the welding and NCCER texts are not allowed.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2009 IMC and SMACNA manuals and 271 CMR. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2009 International Mechanical Code (IMC)Essential

    Allowed in the exam room. Duct, ventilation and exhaust rules behind the journeyman sheet metal exam.

    ICC store (opens in a new tab)

  • NFPA 96 (2008), NFPA 90A, 90B, 92A and 92B (2009)

    Allowed in the exam room. Kitchen exhaust, duct systems and smoke control standards.

  • SMACNA HVAC Duct Construction Standards, Metal and Flexible, 3rd edition (2005), and Architectural Sheet Metal Manual, 7th edition (2012)Essential

    Allowed in the exam room. Duct sizing, construction and hangers; layout and flashing.

    SMACNA (opens in a new tab)

  • 271 CMR: Massachusetts Sheet Metal RegulationEssential

    Allowed in the exam room. State licensing and practice rules.

    Massachusetts regulations (Cornell LII, free to read) (opens in a new tab)

Official reference list (as published by the testing agency)
  • 2009 International Mechanical Code (IMC)
  • NFPA 96 (2008), NFPA 90A, 90B, 92A and 92B (2009)
  • SMACNA HVAC Duct Construction Standards, Metal and Flexible, 3rd edition (2005)
  • SMACNA Architectural Sheet Metal Manual, 7th edition (2012)
  • 271 CMR: Massachusetts Sheet Metal Regulation
  • 29 CFR Part 1926 (OSHA), Modern Welding and NCCER Sheet Metal Levels 1-4 (listed by PSI as sources, not allowed in the exam room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Knowledge8
Safety8
Duct Sizing, Design, Hangers and Supports8
Duct Fabrication and Installation5
Layout12
Ventilation System Accessories and Devices7
Commercial Kitchen Exhaust Systems6
Life Safety Ventilation Systems and Accessories6
Blue Print Reading4
Air Balancing4
Metal Roofing Systems and Accessories4
Plenums and Casing3
Welding5

Exam day details

  • Administered by PSI Services for the Massachusetts Board of Examiners of Sheet Metal Workers.
  • Fee: $180 PSI exam fee (re-examination $180, non-refundable) plus $155 for the application and initial license, paid to the Commonwealth with your application.
  • 80 questions in 150 minutes; 70% to pass. Open book. This practice exam follows the J-1 Unrestricted outline. The Restricted J-2 exam is a smaller subset, and the Metal Roofing exam is not covered.
  • Open book. Bring your own copies of the allowed references; they may be highlighted, underlined, annotated and indexed beforehand with permanent tabs only. You may not write in them during the exam, and loose papers and Post-it tabs are not allowed.
  • Candidates must have the required (or equivalent) apprenticeship experience and education, and the Board approves the application first. Allow about 3 weeks for processing.
  • If you fail, you have 6 months from the application approval date to retake. After three failed attempts you must give the Board proof of self-designed learning objectives or a completed exam preparation course.
  • PSI may add 5 to 10 unscored pretest questions. Cancel at least 2 days ahead or you forfeit the fee. Schedule at test-takers.psiexams.com/mametal or (855) 746-8173.

Frequently asked questions

What is on the Massachusetts journeyman sheet metal exam?

80 questions: layout 12, general knowledge 8, safety 8, duct sizing, design, hangers and supports 8, ventilation accessories and devices 7, commercial kitchen exhaust 6, life safety ventilation 6, duct fabrication and installation 5, welding 5, and smaller sections.

Is it open book?

Yes, with the 2009 IMC, NFPA 96, 90A, 90B, 92A and 92B, both SMACNA manuals and 271 CMR. OSHA 1926 is not allowed in the room.

What does it cost?

$180 to PSI, plus $155 for the application and initial license paid to the Commonwealth.

Free questions with answers

Show all 10 free questions and answers
  1. Under 271 CMR 2.01, which statement correctly separates a journeyperson sheet metal worker from a master?

    Answer: A master may operate a regular place of sheet metal business and employ apprentices, while a journeyperson may supervise apprentices but not employ them

    271 CMR 2.01 defines a journeyperson (Class J-1 or J-2) as authorized to perform sheet metal work and supervise, but not employ, apprentices. A master (M-1 or M-2) is authorized to operate a regular place of sheet metal business and to supervise apprentices. No waiting period or residential-only limit appears in the definitions.

    Reference: 271 CMR (Massachusetts Sheet Metal Regulation), 271 CMR 2.01 (Journey person; Master)

  2. A crew builds a temporary guardrail around a roof opening using a wood top rail. Which top-rail height above the walking surface meets 29 CFR 1926.502(b)(1)?

    Answer: 40 inches

    1926.502(b)(1) sets the top edge of the top rail at 42 inches plus or minus 3 inches above the walking/working level, so 39 to 45 inches complies; 40 inches does. 36, 34 and 30 inches are all below the 39-inch minimum. (The rule lets the top edge exceed 45 inches when conditions warrant, but never go below 39.)

    Reference: 29 CFR 1926 (OSHA Construction), 1926.502(b)(1)

  3. A 20-inch by 12-inch rectangular duct must be replaced by a round duct with the same friction loss at the same airflow. Using the equal-friction equivalent diameter De = 1.3 (ab)^0.625 / (a+b)^0.25, what is the round duct size?

    Answer: About 16.8 inches

    ab = 20 x 12 = 240; 240^0.625 = 30.73; (a+b) = 32 and 32^0.25 = 2.378. De = 1.3 x 30.73 / 2.378 = 16.8 in. The equal-area diameter (17.5 in) preserves cross-section, not friction; the average of the sides (16) and the geometric mean (15.5) are not valid equivalents.

    Reference: General sheet metal practice, Equivalent round duct (equal friction): De = 1.3(ab)^0.625/(a+b)^0.25

  4. Under the 2009 IMC, a listed Class 1 flexible air duct (not an air connector) is used as a long run from a branch to a diffuser. What does Section 603.6.1.1 say about its length?

    Answer: Flexible air ducts shall not be limited in length

    Section 603.6.1.1 of the 2009 IMC states flexible air ducts shall not be limited in length, while flexible air connectors (603.6.2.1) are limited to 14 feet. The two products are treated differently, and a later code edition's length limit should not be applied to this exam. The duct must still be listed Class 0 or Class 1 and installed per its listing (603.6.1).

    Reference: 2009 International Mechanical Code, Section 603.6.1.1 vs 603.6.2.1

  5. A supply branch duct is being tied into a main in a commercial building. Under Section 603.17, where must volume dampers or other means of supply air adjustment be provided, and what else is required?

    Answer: In branch ducts or at each register, grille or diffuser, and each balancing damper must have access

    Section 603.17 requires volume dampers or other means of supply air adjustment in the branch ducts or at each individual duct register, grille or diffuser, and each volume damper or adjustment device used in balancing must be provided with access. Without access, the balancer cannot set or inspect the damper.

    Reference: 2009 International Mechanical Code, Section 603.17

  6. A round 90-degree elbow is built from five pieces (two half-gore end pieces and three full gores). By how many degrees does each of the four seams turn the airflow?

    Answer: 22.5 degrees

    A segmented elbow with five pieces has four seams, and the 90-degree turn is shared evenly among them: 90 / 4 = 22.5 degrees per seam. The cut on each seam is half of that (11.25 degrees) from a square cut. 18 degrees would result from dividing by five pieces, and 30 degrees from a four-piece elbow with three seams.

    Reference: General sheet metal practice, Layout: gored (segmented) elbow, 90 degrees / number of seams

  7. What is the minimum thickness of carbon steel used to build a grease duct serving a Type I hood under Section 506.3.1.1?

    Answer: 0.0575 inch (No. 16 gage)

    Section 506.3.1.1 requires grease ducts to be steel at least 0.0575 inch (No. 16 gage), or stainless steel at least 0.0450 inch (No. 18 gage). The 0.0466-inch (No. 18 gage) steel value is the Type I hood minimum (507.4), a common mix-up.

    Reference: 2009 International Mechanical Code, Section 506.3.1.1

  8. Which smoke damper leakage and elevated temperature rating is the minimum under Section 607.3.2.2?

    Answer: Leakage Class II and an elevated temperature rating of at least 250 degrees F

    Section 607.3.2.2 states smoke damper leakage ratings shall not be less than Class II, and elevated temperature ratings shall not be less than 250 degrees F (121 degrees C). Combination fire/smoke dampers must meet the fire damper rating plus these smoke ratings (607.3.2.3).

    Reference: 2009 International Mechanical Code, Section 607.3.2.2

  9. On a plan drawn at 1/4 inch = 1 foot, a duct run measures 5.375 inches. How long is the run in the building?

    Answer: 21.5 feet

    At 1/4 inch per foot, each inch on the drawing is 4 feet. 5.375 x 4 = 21.5 ft. A 1/8-inch scale would give 43.0 ft, and dividing instead of multiplying gives 1.34.

    Reference: General sheet metal practice, Plan reading: architectural scale conversion

  10. A welding rod is classified as E7018. What does the first part, '70', mean?

    Answer: The deposit has a minimum tensile strength of 70,000 psi

    In an AWS A5.1 classification such as E7018, E means electrode, the first two digits give minimum tensile strength in thousands of psi (70,000 psi), the third digit gives the position (1 = all positions) and the last two digits describe coating and current type (18 = low-hydrogen with iron powder).

    Reference: AWS A5.1 electrode classification (general welding practice), E7018: E = electrode, 70 = ksi tensile strength

Sources

Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.