Requirements at a glance
| Agency | Electricians' Examining Board; exam by Prov |
|---|---|
| Exam | 50 questions, 3 hours, open book, 70% to pass |
| Scope | House wiring in one- and two-family dwellings, including modular and mobile homes |
| Experience | 225 hours of electrical education (45-hour courses in Electricity I, Electricity II, Controls I, Blueprint Reading and the NEC) plus 4,000 hours of experience, at least 2,000 in house wiring |
| Books allowed | NEC (the bulletin prints 2023) |
| Fees | $65 to Prov; board application and license fees are separate |
Electricians who want a Maine limited license for house wiring, which is restricted to one- and two-family dwellings, including modular and mobile homes.
Official links
How to get licensed, step by step
Meet the education and experience requirements
Complete the 225 hours of approved courses and log 4,000 hours of experience, at least 2,000 of them in house wiring.
Maine Office of Professional and Occupational Regulation (opens in a new tab)Maine Revised Statutes Title 32, Chapter 17 (electricians) (opens in a new tab)
Apply to the Electricians' Examining Board
The board reviews your application and approves you to test.
Maine Office of Professional and Occupational Regulation (opens in a new tab)
Schedule with Prov
After the board approves you, book at provexam.com/scheduler (3 Maine centers, or remote through Examroom). If you fail, wait 1 day; there is no attempt limit. You can reschedule free up to 3 days ahead.
Schedule with Prov (opens in a new tab)Prov: Maine OPOR Candidate Information Bulletin (opens in a new tab)
How to prepare
- General electrical knowledge (15) and grounding and bonding (10) are half of the 50 questions.
- Know Article 250 and the dwelling-unit rules in Chapter 2 and Article 210.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2023 National Electrical Code (NEC), NFPA 70Essential
The edition Prov lists for the limited house wiring exam. Allowed in the exam room.
Official reference list (as published by the testing agency)
- NFPA 70 National Electrical Code, 2023 (open book)
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 15 | |
| Service Feeders and Branch Circuits | 5 | |
| Grounding & Bonding | 10 | |
| Raceways and Enclosures | 6 | |
| Conductors & Cables | 7 | |
| Equipment for General Use | 6 | |
| Low Voltage Circuits | 1 |
Exam day details
- Administered by Prov, Inc. for the Maine Office of Professional and Occupational Regulation.
- Fee: $65 to Prov. Board application and license fees are separate.
- 50 questions in 3 hours; 35 correct (70%) to pass.
- Open book: the NEC is the only listed reference.
- The licensing board approves your application first; then you schedule with Prov at a Maine test center or remotely through Examroom.
- If you fail, wait 1 day to retake. There is no limit on attempts. You can reschedule free up to 3 days before your appointment.
Note: The Prov bulletin lists the 2026 NEC for this exam. Maine adopted the 2026 NEC effective July 1, 2026 (Chapter 120), keeping 110.16 at the 2023 text. The Prov bulletin lists the 2023 NEC for the limited house wiring exam, so editions on Prov's pages are mixed. Check the current bulletin before your test date.
Frequently asked questions
What's on the Maine limited house wiring exam?
50 questions: general electrical knowledge 15, grounding and bonding 10, conductors and cables 7, raceways and enclosures 6, equipment for general use 6, service feeders and branch circuits 5 and low voltage circuits 1.
What can a limited house wiring license do?
Work on house wiring systems, including service entrance and low voltage wiring, restricted to one- and two-family dwellings including modular and mobile homes.
Which NEC edition is listed?
Prov lists the 2023 NEC for this exam, while the journeyman and master exams list the 2026 NEC.
Free questions with answers
Show all 10 free questions and answers
A house has 3/0 AWG copper service-entrance conductors. Using Table 250.66, what is the minimum size copper grounding electrode conductor to a metal underground water pipe electrode?
Answer: 4 AWG
Table 250.66 is read by the largest ungrounded service conductor. For copper 2/0 or 3/0 AWG, the copper grounding electrode conductor is 4 AWG. 6 AWG is the row for 1 or 1/0 AWG, and 2 AWG is for conductors over 3/0 through 350 kcmil.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, Table 250.66
A 4/0 AWG copper service uses a single driven ground rod as its only grounding electrode connection. Using 250.66(A), what is the largest copper grounding electrode conductor that has to be installed to that rod, regardless of the Table 250.66 result?
Answer: 6 AWG copper
Table 250.66 would call for 2 AWG for 4/0 service conductors, but where the connection is to a single rod, pipe or plate electrode, 250.66(A) says the conductor is not required to be larger than 6 AWG copper. The 4 AWG limit is for concrete-encased electrodes.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 250.66(A)
What is the maximum overcurrent protection permitted for 12 AWG copper conductors supplying a general-purpose branch circuit in a house, under 240.4(D)?
Answer: 20 amperes
Table 310.16 shows 30 A for 12 AWG copper at 90 degrees C, but 240.4(D) limits overcurrent protection of small conductors: 14 AWG to 15 A, 12 AWG to 20 A and 10 AWG to 30 A (copper). This limit applies after any adjustment and correction factors.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 240.4(D)
Six 12 AWG copper THHN current-carrying conductors are installed in one conduit in an ambient of 30 degrees C. Using the 90 degree C column of Table 310.16 and the adjustment factor of Table 310.15(C)(1), what is the adjusted ampacity?
Answer: 24 amperes
12 AWG THHN is 30 A at 90 degrees C. Four to six current-carrying conductors in one raceway take an 80 percent factor: 30 x 0.80 = 24 A. 21 A would be the 70 percent factor for 7 to 9 conductors, and 30 A ignores the adjustment.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, Table 310.16 and Table 310.15(C)(1)
A 4-inch square, 1-1/2 in. deep metal box (21.0 cu in.) holds a single receptacle. Two 12/2 NM cables with ground enter the box, and the box has internal cable clamps. Using Table 314.16(B)(1) at 2.25 cu in. per 12 AWG conductor, what is the total box fill volume?
Answer: 18.0 cu in.
Count: 4 insulated conductors, 1 allowance for all equipment grounding conductors, 2 for the receptacle yoke and 1 for the clamps, which is 8 allowances. 8 x 2.25 = 18.0 cu in., which fits the 21.0 cu in. box. 15.75 leaves out the clamp allowance, and 20.25 counts each grounding conductor separately.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 314.16(B)
What is the minimum rating of the service disconnecting means for a one-family dwelling under 230.79(C)?
Answer: 100 amperes, 3-wire
230.79(C) says that in a one-family dwelling the service disconnecting means may not be rated less than 100 A, 3-wire. 60 A is the minimum for all other installations in 230.79(D), and 30 A applies to a two-circuit installation under 230.79(B).
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 230.79(C)
Under 404.2(C) of the 2023 NEC, what must be provided at a lighting switch location that controls a general-purpose lighting load in a bathroom, hallway or habitable room?
Answer: The grounded (neutral) conductor of the circuit, unless an exception applies
404.2(C) requires the grounded circuit conductor for the controlled lighting circuit to be installed at switch locations controlling lighting supplied by a general-purpose branch circuit serving bathrooms, hallways, stairways and habitable rooms or occupiable spaces. Where several switches control the same load and the whole room is visible from them, it is needed at only one location. It is not required where the conductors enter through a raceway large enough to add one, for snap switches with integral enclosures under 300.15(E), where lighting is controlled automatically, or where the switch controls a receptacle load. The neutral serves electronic switches that need line-to-neutral standby power.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 404.2(C)
A Class 2 doorbell circuit and 120-volt branch-circuit conductors are both brought into the same device box. Under 725.136, when is this allowed?
Answer: With a barrier, or if it only connects equipment in that box
725.136(A) bars Class 2 and Class 3 conductors from sharing a box, raceway or similar fitting with electric light and power conductors unless a provision in 725.136(B) through (I) applies. Examples are separation by a barrier (B) and conductors introduced solely to connect the equipment in the box (D).
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 725.136
Two 12-ohm resistive heaters are connected in parallel across a 120-volt supply. What is the total circuit resistance?
Answer: 6 ohms
For two equal resistors in parallel, the total is R / 2 = 12 / 2 = 6 ohms (1/Rt = 1/12 + 1/12). 24 ohms is what you would get in series. Current would be 120 / 6 = 20 A.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, Parallel circuits (basic electrical theory)
A one-family dwelling has 2,200 sq ft of floor area. Using 3 VA per sq ft for general lighting and receptacles (220.12), what is the minimum number of 120-volt, 20-ampere general lighting circuits (210.11(A))?
Answer: 3 circuits
Load: 2,200 x 3 = 6,600 VA. At 120 V that is 6,600 / 120 = 55 A. Each 20 A circuit carries 20 A: 55 / 20 = 2.75, which rounds up to 3 circuits. 4 circuits would be needed on 15 A circuits (55 / 15 = 3.67).
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 220.12 and 210.11(A)
Sources
- Prov: Maine OPOR Candidate Information Bulletin (v1.1, November 9, 2026) (opens in a new tab)
- Maine Office of Professional and Occupational Regulation (opens in a new tab)
- Maine Revised Statutes Title 32, Chapter 17 (electricians) (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.