Louisiana licensing exam

Louisiana HVACR Contractor Exam: Practice Test & Licensing Guide

The PSI trade exam for the LSLBC Heating, Air Conditioning, Ventilation and Refrigeration (HVACR) classification: 50 questions on controls, piping, refrigerants, fuel gas, venting, ducts and load calculations. Open book, 70% to pass.

Questions
50
Time limit
2.1666666666666665 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Combustion Air, Chimneys, Flues and Vents

Under the 2021 IFGC standard method for indoor combustion air, what minimum room volume is required for a furnace and a water heater with a combined input of 120,000 Btu/h?

Requirements at a glance

AgencyLouisiana State Licensing Board for Contractors (LSLBC); exams by PSI
Exam50 questions, 130 minutes, 70%
Books allowed2021 IMC and IFGC, ACCA Manual J, Modern Refrigeration, SMACNA and Ugly's
RequirementsBusiness and Law course (not an exam), net worth statement, insurance and other LSLBC requirements
Fees$140 to PSI, plus LSLBC application and license fees

Qualifying parties for a Louisiana HVACR contractor license from the LSLBC.

How to get licensed, step by step

  1. Apply to the LSLBC

    Submit an application for licensure, or a request to add a classification or qualifying party to your license. The Board reviews it before you can test.

    LSLBC: apply for a license (opens in a new tab)Louisiana State Licensing Board for Contractors (LSLBC) (opens in a new tab)

  2. Schedule with PSI

    Once approved you get an e-mail from PSI to pay and schedule. Eligibility is good for one year; after that you reapply with the Board.

    Schedule with PSI (Louisiana contractors) (opens in a new tab)

  3. Take the open-book exam

    Bring your own tabbed references. 70% is passing.

    Schedule with PSI (Louisiana contractors) (opens in a new tab)

  4. Finish your license

    Complete the Business and Law course and the remaining LSLBC requirements to be licensed.

    Louisiana State Licensing Board for Contractors (LSLBC) (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's outline. Louisiana's adopted codes are the 2021 ICC codes and the 2020 NEC, but several PSI exams list other editions (the 2023 NEC, 2018 ICC books). The 2023 NEC and 2024 ICC codes take effect January 1, 2027.
  • Tab your books before exam day. You can highlight, underline and index them with permanent tabs, but you can't write in them, and sticky notes are removed.
  • Heating and cooling principles (8) and refrigerants and refrigeration (8) lead. Know superheat, subcooling and the refrigeration cycle.
  • Tab IMC Chapters 4 to 6 and 11 and IFGC Chapters 3 to 5 for ventilation, combustion air, ducts and venting.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2021 IMC and the 2021 IFGC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Mechanical Code (IMC), 2021 Edition
  • International Fuel Gas Code (IFGC), 2021 Edition
  • ACCA Manual J (2016 reprint)
  • Modern Refrigeration and Air Conditioning, 20th or 21st Edition
  • SMACNA HVAC Duct Construction Standards (2005)
  • Ugly's Electrical References, 2014, 2017 or 2020 edition

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Electrical Knowledge, Motors, and Controls7
Piping - Refrigeration, Hydronic, Steam, Process7
Heating and Cooling Principles, Theory, and Equipment8
Refrigerants and Refrigeration8
Fuel and LP Gas5
Combustion Air, Chimneys, Flues and Vents5
Ducts, Ventilation and Exhaust5
Load Calculations5

Exam day details

  • Administered by PSI Services for the Louisiana State Licensing Board for Contractors (LSLBC).
  • Fee: $140 to PSI. LSLBC application and license fees are separate.
  • 50 questions in 130 minutes; 35 correct (70%) to pass.
  • Open book: bring your own copies of the allowed references. You may highlight, underline and index them beforehand, but not write in them during the exam. Temporary tabs such as sticky notes are removed.
  • PSI may add unscored experimental questions, which count against your time.
  • The LSLBC must approve your application (or your request to add a classification) first. PSI then e-mails your eligibility, which is good for one year; if you haven't passed by then you reapply with the Board.
  • Business and Law is a required course, not an exam, so there is no separate business exam to take.
  • Code questions are based only on the edition PSI lists. For other references, later editions are fine.

Frequently asked questions

What's on the Louisiana HVACR exam?

50 questions: heating and cooling principles and equipment 8, refrigerants and refrigeration 8, electrical knowledge, motors and controls 7, piping 7, fuel and LP gas 5, combustion air, chimneys, flues and vents 5, ducts, ventilation and exhaust 5, and load calculations 5.

Which code editions are on the HVACR exam?

The 2021 IMC and 2021 IFGC, which match Louisiana's adopted codes.

Is the HVACR exam different from Mechanical Work?

Yes. HVACR is a shorter 50-question exam without plumbing. Mechanical Work is 100 questions and also covers plumbing and gas systems.

Free questions with answers

Show all 10 free questions and answers
  1. Under the 2021 IFGC standard method for indoor combustion air, what minimum room volume is required for a furnace and a water heater with a combined input of 120,000 Btu/h?

    Answer: 6,000 cubic feet

    Section 304.5.1 requires 50 cubic feet per 1,000 Btu/h of total input. 120,000 / 1,000 = 120; 120 x 50 = 6,000 cubic feet. 2,400 uses 20 ft3 per 1,000, and 12,000 doubles the rate.

    Reference: 2021 International Fuel Gas Code, Section 304.5.1

  2. Using 2021 IFGC Table 402.4(2) (natural gas, Schedule 40 steel, under 2 psi inlet, 0.5 in. w.c. drop, 0.60 specific gravity), what is the smallest pipe size for a 150,000 Btu/h furnace at the end of a 60-foot run? Assume 1,000 Btu per cubic foot.

    Answer: 1 inch

    150,000 Btu/h / 1,000 Btu/ft3 = 150 cfh. In the 60-foot row, 1/2-inch pipe carries 65 cfh, 3/4-inch carries 137 cfh and 1-inch carries 257 cfh. 137 is less than 150, so 3/4 inch is too small and 1 inch is the smallest that works.

    Reference: 2021 International Fuel Gas Code, Table 402.4(2)

  3. Under 2021 IMC Section 403.3.2.1, Equation 4-9 (QOA = 0.01 x floor area + 7.5 x (number of bedrooms + 1)), what continuous outdoor airflow is required for a 2,000-square-foot, three-bedroom dwelling unit?

    Answer: 50 cfm

    Equation 4-9: 0.01 x 2,000 = 20 cfm; 7.5 x (3 + 1) = 30 cfm; total = 50 cfm. 35 results from using 7.5 x (3 - 1) = 15 for the person term (20 + 15), 42.5 from using 7.5 x 3 = 22.5 (20 + 22.5), and 20 is the floor-area term alone.

    Reference: 2021 International Mechanical Code, Section 403.3.2.1, Equation 4-9

  4. A system's suction pressure corresponds to a saturation temperature of 40 degrees F, and the suction line temperature measured near the evaporator outlet is 52 degrees F. What is the superheat?

    Answer: 12 degrees F

    Superheat = actual suction line temperature minus the saturation temperature at suction pressure = 52 - 40 = 12 degrees F. Adding the numbers (92) or reporting the saturation temperature (40) are common errors.

    Reference: General HVACR practice, Superheat measurement (refrigeration cycle fundamentals)

  5. The head pressure of a system corresponds to a condensing saturation temperature of 105 degrees F and the liquid line temperature at the condenser outlet is 95 degrees F. What is the subcooling?

    Answer: 10 degrees F

    Subcooling = condensing saturation temperature minus liquid line temperature = 105 - 95 = 10 degrees F. Superheat uses the opposite order (actual minus saturation) on the suction side.

    Reference: General HVACR practice, Subcooling measurement (refrigeration cycle fundamentals)

  6. A 400 sq ft wall assembly has these layer R-values: outside air film 0.17, siding 0.61, sheathing 1.32, R-13 batt, drywall 0.45, inside air film 0.68. For a 60 degree F design temperature difference, what is the conduction heat loss through the wall? Use Q = A x TD / R-total.

    Answer: About 1,479 Btu/h

    R-total = 0.17 + 0.61 + 1.32 + 13 + 0.45 + 0.68 = 16.23; U = 1 / 16.23 = 0.0616. Q = U x A x TD = 0.0616 x 400 x 60 = 1,479 Btu/h. 1,846 uses only the R-13 batt (400 x 60 / 13), 1,560 omits the air films (400 x 60 / 15.38), and multiplying by R instead of dividing gives 389,520.

    Reference: General HVACR practice, Series R-value conduction heat loss (Manual J method)

  7. Three heating elements of 10, 20 and 30 ohms are connected in series across 120 volts. What current flows in the circuit?

    Answer: 2 amperes

    Series resistances add: 10 + 20 + 30 = 60 ohms. I = 120 / 60 = 2 amperes, the same everywhere in a series circuit. 12 amperes is what the 10-ohm element alone would draw, and 6 comes from the 20-ohm element.

    Reference: General HVACR practice, Series circuits, total resistance and current

  8. What is the minimum condensate drain pipe diameter for equipment of up to 20 tons of refrigeration under 2021 IMC Table 307.2.2?

    Answer: 3/4 inch

    Table 307.2.2 sets 3/4 inch for equipment up to 20 tons, 1 inch for over 20 to 40 tons, and 1-1/4 inch for over 40 to 90 tons.

    Reference: 2021 International Mechanical Code, Table 307.2.2

  9. A furnace is installed in an attic. Under 2021 IMC Section 306.3, what are the minimum passageway dimensions and the maximum length if the passageway is not 6 feet high?

    Answer: 30 inches high, 22 inches wide, and not more than 20 feet long

    Section 306.3 requires an unobstructed passageway at least 30 inches high and 22 inches wide, not over 20 feet from the opening to the appliance, with solid flooring at least 24 inches wide. Where the passageway is at least 6 feet high and 22 inches wide, the length may be up to 50 feet.

    Reference: 2021 International Mechanical Code, Section 306.3

  10. Under 2021 IMC Section 1109.8.1, where are stop valves required on a refrigerating system with over 6.6 pounds of refrigerant (no pump-out or recovery exception applying)?

    Answer: Compressor suction inlet and discharge outlet, and each liquid receiver outlet

    Section 1109.8.1 requires stop valves at the suction inlet and discharge outlet of each compressor, compressor unit or condensing unit, and at the outlet of each liquid receiver. Exceptions include systems with pump-out capability, systems with provisions for recovery equipment, and self-contained listed systems.

    Reference: 2021 International Mechanical Code, Section 1109.8.1

Sources

Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.