Requirements at a glance
| Agency | Your Kansas city or county licenses you; the International Code Council (ICC) gives the exam through Pearson VUE. There is no statewide license |
|---|---|
| Experience | Set by your city or county. Sedgwick County accepts the KGX exam for residential-only certification |
| Exam | KGX: 60 questions, 3 hours, 75% |
| Books allowed | 2017 NEC and Ugly's Electrical References (any edition) |
| Fees | $115 per ICC exam (national T-series exams are $120), plus your city or county's certificate or license fees |
Electricians who work only on residential wiring in a Kansas city or county that accepts the ICC residential exam; Sedgwick County accepts it for residential-only certificates.
Official links
How to get licensed, step by step
Ask your city or county which exam it accepts
Kansas law lets each jurisdiction name the standard examinations it accepts as proof of competency. Confirm the exam and the experience rules before you pay.
Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)Kansas statute K.S.A. 12-1525 (standard examinations) (opens in a new tab)
Register for the residential electrician exam (KGX) with ICC and Pearson VUE
Create an ICC account, pick the Kansas standard exam from the Exam Catalog and schedule a Pearson VUE appointment. If you fail, wait 10 days to retake.
Schedule with Pearson VUE (ICC exams) (opens in a new tab)ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)
Pass at 75% with your books
The exam is open book with four-option multiple choice and no penalty for guessing. Bring only the approved references.
ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)
Apply to your city or county
Send your passing score and proof of experience to the jurisdiction, with its fee. It issues the certificate or license and sets renewal rules.
Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)
How to prepare
- Study the edition the exam is built on: the 2017 NEC for electrical and the 2018 IPC, IMC and IFGC for plumbing and mechanical. Your city's adopted code can be newer.
- The exam is open book, but there is not time to look up every answer. Tab your books by chapter and table before exam day.
- The 2014 NEC / 2015 I-Code Kansas exams end December 1, 2026. If your jurisdiction wants a 2021-based exam, ask about the national ICC T-series instead.
- Branch circuits and conductors (25%) and services and service equipment (22%) are nearly half the exam: tab Articles 210, 220 (dwelling load calculations), 230 and 250.
- Feeders (13%) and wiring methods (13%) come from Articles 215 and 300 through 340.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2017 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2017 EditionEssential
Allowed in the exam room. The Kansas standard electrician exams are built on the 2017 edition, not the newer NEC your city may enforce.
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for voltage drop, power, motors and load calculations.
Official reference list (as published by the testing agency)
- 2017 National Electrical Code (NEC) (allowed in the exam room)
- Ugly's Electrical References (any edition) (allowed in the exam room)
What's on the exam
Official content outline from International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 12 | |
| Services and Service Equipment | 22 | |
| Feeders | 13 | |
| Branch Circuits and Conductors | 25 | |
| Wiring Methods and Materials | 13 | |
| Equipment and Devices | 8 | |
| Special Occupancies, Equipment, and Conditions | 7 |
The outline totals 100; the other items on the 60-question exam are unscored or unassigned.
Exam day details
- Administered by International Code Council (ICC), delivered by Pearson VUE, for Kansas cities and counties.
- Fee: $115 to ICC through Pearson VUE per exam. Your city or county's license fees are separate.
- 60 multiple-choice questions in 3 hours; 45 correct (75%) to pass.
- Open book: bring the approved references. Questions are four-option multiple choice with no penalty for guessing; 75% to pass.
- Kansas has no statewide electrician, plumber or mechanical license. ICC only tests; the city or county where you want to work sponsors you and issues the license.
- If you fail, wait 10 days to retake.
- The 2014 NEC / 2015 I-Code exams stop being offered December 1, 2026. These Kansas standard exams are based on the 2017 NEC and 2018 I-Codes; the national T-series exams cover the 2020 NEC and 2021 I-Codes.
Frequently asked questions
What's on the Kansas residential electrician exam?
60 questions by weight: branch circuits and conductors 25%, services and service equipment 22%, feeders 13%, wiring methods and materials 13%, general knowledge 12%, equipment and devices 8% and special occupancies 7%.
Can I work commercially with the residential license?
Usually not. Sedgwick County, for example, accepts the residential exam for residential-only certification. Ask your city or county.
Which code book does the Kansas exam use?
The 2017 NEC, plus Ugly's Electrical References (any edition).
Free questions with answers
Show all 10 free questions and answers
A new single-family house is being wired and its calculated load is only 60 amperes. What is the smallest rating permitted for the service disconnecting means under the 2017 NEC?
Answer: 100 amperes, 3-wire
Section 230.79(C) requires the service disconnecting means for a one-family dwelling to be rated not less than 100 amperes, 3-wire, whatever the calculated load. The 60-ampere figure in 230.79(D) applies to other installations. Larger sizes such as 150 or 200 A are design choices, not the code minimum.
Reference: NFPA 70, National Electrical Code, 2017, 230.79(C)
A dwelling has 250 kcmil copper service-entrance conductors. Table 250.66 would call for 2 AWG copper for the grounding electrode conductor, but this GEC runs only to a concrete-encased electrode. What is the largest copper size the GEC is required to be?
Answer: 4 AWG
Section 250.66(B) says that where a GEC connects only to a concrete-encased electrode, that portion of the conductor is not required to be larger than 4 AWG copper, even if Table 250.66 would require more. 6 AWG is the limit for a rod, pipe or plate electrode under 250.66(A). 2 AWG would be the table value that the limit replaces.
Reference: NFPA 70, National Electrical Code, 2017, 250.66(B), Table 250.66
A bedroom has a straight wall space 14 ft long with no doorways or fixed openings. Using the wall-space spacing rule of 210.52(A)(1), what is the minimum number of receptacle outlets that must be installed along this wall?
Answer: 2
Section 210.52(A)(1) requires receptacles so that no point measured horizontally along the floor line of any wall space is more than 6 ft from a receptacle, which means receptacles no more than 12 ft apart. One receptacle placed in the middle covers only 6 ft each way (12 ft total) and leaves 2 ft uncovered, so two are needed. Three would exceed the minimum.
Reference: NFPA 70, National Electrical Code, 2017, 210.52(A)(1)
A dwelling has these fastened-in-place appliances: a 1,200 VA dishwasher, an 800 VA disposal, a 3,000 VA water heater, a 1,200 VA trash compactor and a 600 VA central vacuum. Using the standard method, what load is added for these appliances?
Answer: 5,100 VA
Section 220.53 allows a 75% demand factor for four or more fastened-in-place appliances (not ranges, dryers, space heating or air conditioning) on the same feeder or service. The total is 1,200 + 800 + 3,000 + 1,200 + 600 = 6,800 VA; 6,800 x 0.75 = 5,100 VA. 6,800 VA ignores the demand factor, 4,080 VA uses 60%, and 3,400 VA uses 50%.
Reference: NFPA 70, National Electrical Code, 2017, 220.53
A dwelling has one household electric range rated 16 kW. Using Table 220.55, Column C, and its Note 1, what demand load is used for the range?
Answer: 9.6 kW
Table 220.55, Column C, gives 8 kW for one range not over 12 kW. Note 1 says that for a range over 12 kW through 27 kW, the column value is increased 5% for each kW over 12. This range is 4 kW over, so the increase is 20%: 8 x 1.20 = 9.6 kW. 8.0 kW forgets Note 1, 12.8 kW takes 80% of the nameplate, and 16.0 kW uses the nameplate with no demand factor.
Reference: NFPA 70, National Electrical Code, 2017, 220.55, Table 220.55 Note 1
A 2,000-watt baseboard heater is rated for 240 volts. What is the resistance of the heating element?
Answer: 28.8 ohms
Using P = E squared / R, R = E squared / P = 240 x 240 / 2,000 = 57,600 / 2,000 = 28.8 ohms. 8.3 is the current in amperes (2,000 / 240), not ohms; 7.2 ohms uses 120 volts instead of the rated 240 volts (14,400 / 2,000); 120 ohms halves the voltage (240 / 2) instead of squaring it.
Reference: General electrical theory (power formula), General electrical theory (power formula)
What is the maximum interval at which Type NM cable run along framing must be secured, in addition to being secured within 12 in of each box?
Answer: 4 1/2 ft
Section 334.30 requires NM cable to be secured by staples, straps or similar fittings at intervals not exceeding 4 1/2 ft and within 12 in of every box, cabinet or fitting. 6 ft is the interval for other cable types such as Type MC, not NM.
Reference: NFPA 70, National Electrical Code, 2017, 334.30
An EMT run will hold ten 12 AWG THHN conductors (0.0133 sq in each from Chapter 9, Table 5). Using Table 1 for over two conductors and the 40% areas of Table 4 (1/2 in = 0.122 sq in; 3/4 in = 0.213 sq in; 1 in = 0.346 sq in), what is the smallest trade size?
Answer: 3/4 in
Total conductor area = 10 x 0.0133 = 0.133 sq in. With more than two conductors, 40% fill applies (Chapter 9, Table 1). The 40% area of 1/2-in EMT is 0.122 sq in, which is too small. 3/4-in EMT allows 0.213 sq in, so 3/4 in is the minimum. 1 in and larger are permitted but not the smallest.
Reference: NFPA 70, National Electrical Code, 2017, Chapter 9, Tables 1, 4 and 5
Under 406.12 of the 2017 NEC, what is required of a new 125-volt, 15-ampere nonlocking receptacle installed in a dwelling bedroom?
Answer: It must be tamper-resistant
Section 406.12 requires nonlocking-type 125-volt, 15- and 20-ampere receptacles in the areas specified in 210.52, including bedrooms, to be listed tamper-resistant. A bedroom receptacle does not need GFCI under the 2017 list in 210.8(A), and there is no minimum mounting height in the code for dwelling receptacles.
Reference: NFPA 70, National Electrical Code, 2017, 406.12
At a permanently installed residential swimming pool, what is the farthest distance from the inside wall of the pool at which the required general-purpose receptacle may be placed under 680.22(A)(1)?
Answer: 20 ft
Section 680.22(A)(1) requires at least one 125-volt, 15- or 20-ampere receptacle on a general-purpose branch circuit, located not less than 6 ft and not more than 20 ft from the inside wall of the pool. It must also not be more than 6 1/2 ft above the floor, platform or grade serving the pool.
Reference: NFPA 70, National Electrical Code, 2017, 680.22(A)(1)
Sources
- ICC: State of Kansas Contractor/Trades Examination Information Bulletin (10/12/2026) (opens in a new tab)
- Pearson VUE: ICC exams (opens in a new tab)
- Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)
- Johnson County Contractor Licensing: exam information (opens in a new tab)
Questions last verified November 4, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.