Requirements at a glance
| Agency | Your Kansas city or county licenses you; the International Code Council (ICC) gives the exam through Pearson VUE. There is no statewide license |
|---|---|
| Experience | Set by your city or county. Sedgwick County/Wichita: 2 years in the field, or 1 year in the field plus 1 year of trade school, for a journeyman certificate |
| Exam | KGH: 80 questions, 4 hours, 75% |
| Books allowed | 2017 NEC and Ugly's Electrical References (any edition) |
| Fees | $115 per ICC exam (national T-series exams are $120), plus your city or county's certificate or license fees |
Electricians applying for a journeyman certificate or license from a Kansas city or county that accepts the ICC standard exam, such as Sedgwick County/Wichita (2 years in the field, or 1 year plus 1 year of trade school).
Official links
How to get licensed, step by step
Ask your city or county which exam it accepts
Kansas law lets each jurisdiction name the standard examinations it accepts as proof of competency. Confirm the exam and the experience rules before you pay.
Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)Kansas statute K.S.A. 12-1525 (standard examinations) (opens in a new tab)
Register for the journeyman electrician exam (KGH) with ICC and Pearson VUE
Create an ICC account, pick the Kansas standard exam from the Exam Catalog and schedule a Pearson VUE appointment. If you fail, wait 10 days to retake.
Schedule with Pearson VUE (ICC exams) (opens in a new tab)ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)
Pass at 75% with your books
The exam is open book with four-option multiple choice and no penalty for guessing. Bring only the approved references.
ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)
Apply to your city or county
Send your passing score and proof of experience to the jurisdiction, with its fee. It issues the certificate or license and sets renewal rules.
Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)
How to prepare
- Study the edition the exam is built on: the 2017 NEC for electrical and the 2018 IPC, IMC and IFGC for plumbing and mechanical. Your city's adopted code can be newer.
- The exam is open book, but there is not time to look up every answer. Tab your books by chapter and table before exam day.
- The 2014 NEC / 2015 I-Code Kansas exams end December 1, 2026. If your jurisdiction wants a 2021-based exam, ask about the national ICC T-series instead.
- Wiring methods and materials (26%) and branch circuits and conductors (19%) are almost half the exam: tab NEC Chapter 3 and Articles 210, 220 and 240.
- Learn Chapter 9 Tables 4, 5 and 8 and Annex C for conduit fill, and practice load and voltage drop calculations with Ugly's.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2017 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2017 EditionEssential
Allowed in the exam room. The Kansas standard electrician exams are built on the 2017 edition, not the newer NEC your city may enforce.
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for voltage drop, power, motors and load calculations.
Official reference list (as published by the testing agency)
- 2017 National Electrical Code (NEC) (allowed in the exam room)
- Ugly's Electrical References (any edition) (allowed in the exam room)
What's on the exam
Official content outline from International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 6 | |
| Services and Service Equipment | 11 | |
| Feeders | 4 | |
| Branch Circuits and Conductors | 19 | |
| Wiring Methods and Materials | 26 | |
| Equipment and Devices | 13 | |
| Control Devices | 4 | |
| Motors and Generators | 6 | |
| Special Occupancies, Equipment, and Conditions | 11 |
The outline totals 100; the other items on the 80-question exam are unscored or unassigned.
Exam day details
- Administered by International Code Council (ICC), delivered by Pearson VUE, for Kansas cities and counties.
- Fee: $115 to ICC through Pearson VUE per exam. Your city or county's license fees are separate.
- 80 multiple-choice questions in 4 hours; 60 correct (75%) to pass.
- Open book: bring the approved references. Questions are four-option multiple choice with no penalty for guessing; 75% to pass.
- Kansas has no statewide electrician, plumber or mechanical license. ICC only tests; the city or county where you want to work sponsors you and issues the license.
- If you fail, wait 10 days to retake.
- The 2014 NEC / 2015 I-Code exams stop being offered December 1, 2026. These Kansas standard exams are based on the 2017 NEC and 2018 I-Codes; the national T-series exams cover the 2020 NEC and 2021 I-Codes.
Frequently asked questions
What's on the Kansas journeyman electrician exam?
80 questions by weight: wiring methods and materials 26%, branch circuits and conductors 19%, equipment and devices 13%, services and service equipment 11%, special occupancies 11%, general knowledge 6%, motors and generators 6%, feeders 4% and control devices 4%.
Which code book does the Kansas exam use?
The 2017 NEC, plus Ugly's Electrical References (any edition). Your city or county may have adopted a newer NEC for inspections, but this exam is built on the 2017 edition.
Does Kansas have a state electrician license?
No. Cities and counties license electricians and accept ICC exams as proof of competency. A 2026 bill for statewide licensing (HB 2588) did not pass.
Free questions with answers
Show all 10 free questions and answers
A 240-volt electric baseboard heater draws 12 amperes. What is the resistance of the heating element?
Answer: 20 ohms
Ohm's law: R = E / I = 240 / 12 = 20 ohms. The 2,880 figure is E x I (watts), not resistance, and 0.05 comes from inverting the formula (I / E).
Reference: NFPA 70, National Electrical Code, 2017, General electrical theory (Ohm's law, R = E / I)
A one-family dwelling has 2,400 sq ft of floor area. Using a 3 VA per square foot general lighting load, add two 1,500-VA small-appliance circuits and one 1,500-VA laundry circuit, then apply the Table 220.42 lighting demand factors (first 3,000 VA at 100 percent, 3,001 to 120,000 VA at 35 percent). What is the demand load of these loads?
Answer: 6,045 VA
General lighting is 2,400 x 3 = 7,200 VA. Adding the small-appliance (2 x 1,500 = 3,000 VA) and laundry (1,500 VA) loads gives 11,700 VA. Demand: first 3,000 VA at 100 percent = 3,000; the remaining 8,700 VA x 0.35 = 3,045; total 6,045 VA. 11,700 VA ignores demand factors and 7,200 VA omits the appliance circuits.
Reference: NFPA 70, National Electrical Code, 2017, 220.12; 220.52(A) and (B); Table 220.42
In a three-way switch circuit that controls one lighting outlet from two locations, which conductor must be the one that is switched?
Answer: The ungrounded conductor
404.2(A) requires three-way and four-way switches to be wired so that all switching is done only in the ungrounded circuit conductor. Switching the grounded conductor would leave the lampholder energized when the switch is off, and the equipment grounding conductor is never switched.
Reference: NFPA 70, National Electrical Code, 2017, 404.2(A)
A service uses 3/0 AWG copper ungrounded conductors, and the grounding electrode conductor connects only to a single ground rod. What is the largest copper conductor required for that connection under 250.66(A)?
Answer: 6 AWG
Table 250.66 alone would call for 4 AWG copper for 3/0 AWG service conductors, but 250.66(A) states that where the conductor runs to a rod, pipe or plate electrode, it is not required to be larger than 6 AWG copper. The 4 AWG limit in 250.66(B) applies to concrete-encased electrodes.
Reference: NFPA 70, National Electrical Code, 2017, 250.66(A); Table 250.66
A single-phase, 230-volt, 5 hp continuous-duty motor has a Table 430.248 full-load current of 28 A. What is the minimum branch-circuit conductor ampacity required by 430.22?
Answer: 35 amperes
430.22 requires branch-circuit conductors for a single motor to be at least 125 percent of the full-load current from the table (430.6(A)(1)): 28 x 1.25 = 35 A. Using 28 A omits the 125 percent factor, and 42 A uses 150 percent.
Reference: NFPA 70, National Electrical Code, 2017, 430.22; 430.6(A)(1); Table 430.248
Under 210.52(A)(1), in the wall spaces of a dwelling living room, receptacles must be placed so that no point along the floor line of a usable wall space is more than how far from a receptacle outlet?
Answer: 6 feet
210.52(A)(1) requires receptacles so that no point measured horizontally along the floor line of any wall space is more than 6 ft from a receptacle outlet, which means receptacles no more than 12 ft apart. The 12 ft figure is the spacing, not the maximum distance to a receptacle.
Reference: NFPA 70, National Electrical Code, 2017, 210.52(A)(1)
What is the minimum number of 20-ampere small-appliance branch circuits required by 210.11(C)(1) to serve the kitchen, pantry, breakfast and dining room receptacles of a dwelling?
Answer: Two
210.11(C)(1) requires two or more 20 A small-appliance branch circuits for the receptacle outlets covered by 210.52(B). Those circuits are in addition to the laundry circuit (210.11(C)(2)) and the bathroom circuit (210.11(C)(3)).
Reference: NFPA 70, National Electrical Code, 2017, 210.11(C)(1); 210.52(B)
Table 314.16(A) lists a 4-11/16 in. square metal box that is 2-1/8 in. deep with a volume of 42.0 cubic inches. With no devices, clamps or fittings, what is the maximum number of 12 AWG conductors it can contain?
Answer: 18 conductors
Each 12 AWG conductor requires 2.25 cu in (Table 314.16(B)). 42.0 / 2.25 = 18.67, and the result is rounded down because a partial conductor cannot be installed: 18 conductors. 19 would exceed the box volume.
Reference: NFPA 70, National Electrical Code, 2017, Table 314.16(A); Table 314.16(B)
A panelboard rated 480 volts has exposed live parts on one side of the working space and exposed live parts on the other side as well, with no guards. Under Table 110.26(A)(1), what minimum depth of working space is required (Condition 3, 151 to 600 volts to ground)?
Answer: 4 feet
Table 110.26(A)(1) lists 3 ft for Condition 1 (live parts on one side, nothing on the other), 3-1/2 ft for Condition 2 (live parts on one side, grounded parts on the other) and 4 ft for Condition 3 (live parts on both sides). The 3-1/2 ft depth applies where only one side is live.
Reference: NFPA 70, National Electrical Code, 2017, 110.26(A)(1), Table 110.26(A)(1)
Under 500.5(B)(1), a Class I, Division 1 location is one in which ignitible concentrations of flammable gases or vapors:
Answer: Exist under normal operating conditions
Division 1 locations are those where ignitible concentrations exist under normal operating conditions, frequently because of repair, maintenance or leakage, or where equipment failure could release them and also cause an electrical failure. Division 2 locations are those where the hazard is handled only in closed systems or is normally prevented by ventilation.
Reference: NFPA 70, National Electrical Code, 2017, 500.5(B)(1)
Sources
- ICC: State of Kansas Contractor/Trades Examination Information Bulletin (10/12/2026) (opens in a new tab)
- Pearson VUE: ICC exams (opens in a new tab)
- Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)
- Johnson County Contractor Licensing: exam information (opens in a new tab)
Questions last verified November 4, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.