Illinois licensing exam

Illinois Private Alarm Contractor Exam: Practice Test & Licensing Guide

Practice for the Illinois Private Alarm Contractor license exam from IDFPR, given by CTS: 75 minutes on licensure and practice requirements, fire alarm systems and security alarm systems. 70 to pass.

Questions
Not published by Illinois
Time limit
75 min
Passing score
70%
Books
Not published by Illinois
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Licensure & Practice Requirements

What is the minimum age an individual must be to qualify for licensure as an Illinois private alarm contractor?

Requirements at a glance

AgencyIllinois Department of Financial and Professional Regulation (IDFPR); exam by Continental Testing Services (CTS)
EligibilitySet by the Private Detective, Private Alarm, Private Security and Locksmith Act: verifiable experience and education plus good moral character. Contact IDFPR for details
Exam75 minutes, 70 to pass; CTS gives topic question ranges but no total
Book allowedNot stated by CTS
Fee$298 (CTS); not refundable

Anyone seeking an Illinois Private Alarm Contractor license under the Private Detective, Private Alarm, Private Security and Locksmith Act. Eligibility (experience, education, good moral character) is set by the Act; contact IDFPR for details.

How to get licensed, step by step

  1. Apply to IDFPR

    Get the application packet from IDFPR. You are told whether your candidacy is accepted or denied, and the exam date, time and site about 10 days before the test.

    IDFPR: Private Alarm Contractor licensing (opens in a new tab)

  2. Register with CTS

    Use the CTS Illinois schedule. There are no make-up exams and no refunds; a missed exam is re-registered for the next date.

    Continental Testing Services: Illinois exams (opens in a new tab)

  3. Study the references

    NFPA 72 (2022), NFPA 730 and 731 (2023), NFPA 101 (2024), NFPA 70 (2023), the TMA central station guide and the Act and Rules.

    IDFPR: Private Alarm Contractor licensing (opens in a new tab)

  4. Pass with 70

    A pass notice includes the licensure application. There is no limit on retakes while your application remains valid.

    Continental Testing Services: Illinois exams (opens in a new tab)

How to prepare

  • CTS prints ranges (licensure 8-10, fire alarm 31-35, security 26-30) with two to four questions per subtopic; our total is a practice setting.
  • Fire alarm and security alarm together are most of the exam; both include wiring methods, grounding and overcurrent protection, so know the NEC basics.
  • CTS does not say whether the exam is open book; plan as if it is closed.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • NFPA 72 National Fire Alarm and Signaling Code Handbook, 2022Essential

    Main fire alarm reference for CTS's private alarm contractor exam. NFPA 101 (2024) and NFPA 70 (2023) are also listed.

  • NFPA 730 (2023) and NFPA 731 (2023): premises securityEssential

    CTS references for the security alarm part.

Official reference list (as published by the testing agency)
  • NFPA 72, National Fire Alarm and Signaling Code Handbook, 2022
  • NFPA 730, Guide for Premises Security, 2023
  • NFPA 731, Standard for Installation of Electronic Premises Security Systems, 2023
  • NFPA 101, Life Safety Code or Life Safety Code Handbook, 2024
  • NFPA 70, National Electrical Code or NEC Handbook, 2023
  • Bukowski and Moore, Fire Alarm Signaling Systems, 4th Edition (2010)
  • A Practical Guide to Central Station Burglar Alarm Systems, 5th Edition (2018), The Monitoring Association
  • 2024 OSHA Construction Safety Handbook, 7th Edition (J.J. Keller)
  • Private Detective, Private Alarm, Private Security and Locksmith Act and Rules (IDFPR)

What's on the exam

Official content outline from Continental Testing Services (CTS) (number of questions per topic):

TopicQuestions
Licensure & Practice Requirements9
Design/Install/Maintain/Service Fire Alarm Systems33
Design/Install/Maintain/Service Security Alarm Systems28

Exam day details

  • Administered by Continental Testing Services (CTS) for the Illinois Department of Financial and Professional Regulation (IDFPR).
  • Fee: $298
  • The exam is timed at 75 minutes; 70 to pass. CTS prints question-count ranges (8-10 licensure, 31-35 fire alarm, 26-30 security) but no total; our 9, 33 and 28 are midpoints and our 70-question length is a practice setting.
  • CTS does not say whether the exam is open or closed book, so we assume closed.
  • Each subtopic in CTS's outline gets two to four questions. Fire alarm covers NFPA 72 detection, signaling, central station and household systems; security covers NFPA 730/731, burglar alarms, access control and video.
  • CTS fee is $298 and is not refundable; there are no make-up exams, and you can retake as long as your application remains valid.
  • CTS says revisions to the state law and NFPA standards issued as of January 1, 2019 are included by reference.

Note: CTS publishes question-count ranges but not a total or an open/closed-book rule, so our question count and closed-book setting are estimates.

Frequently asked questions

How many questions are on the Illinois private alarm contractor exam?

CTS publishes ranges, not a total: 8 to 10 on licensure and practice, 31 to 35 on fire alarm systems and 26 to 30 on security alarm systems. The exam is 75 minutes with 70 to pass.

Which code editions does it use?

NFPA 72 2022, NFPA 730 and 731 2023, NFPA 101 2024 and NFPA 70 (NEC) 2023, plus the Private Detective, Private Alarm, Private Security and Locksmith Act and Rules.

What does the exam cost?

$298 on CTS's Illinois schedule, not refundable.

Free questions with answers

Show all 10 free questions and answers
  1. What is the minimum age an individual must be to qualify for licensure as an Illinois private alarm contractor?

    Answer: 21 years old

    Section 20-10(a)(1) requires a private alarm contractor applicant to be at least 21. Eighteen is the minimum age for a permanent employee registration card (Section 35-30(a)), which is a different credential; armed employees must be 21.

    Reference: Private Detective, Private Alarm, Private Security, Fingerprint Vendor, and Locksmith Act of 2004 (225 ILCS 447), 225 ILCS 447/20-10(a)(1)

  2. An applicant for a private alarm contractor license was convicted of a felony and discharged from the sentence 6 years ago. Under the felony provision of the Act, what is the effect?

    Answer: The applicant is not qualified until at least 10 years have elapsed since full discharge from the sentence

    Section 20-10(a)(2) requires either no felony conviction in any jurisdiction or at least 10 years since full discharge. Non-felony convictions are different: they may be weighed in deciding good moral character but are not an absolute bar, except for registered sex offenders (20-10(a)(3)).

    Reference: Private Detective, Private Alarm, Private Security, Fingerprint Vendor, and Locksmith Act of 2004 (225 ILCS 447), 225 ILCS 447/20-10(a)(2)

  3. An armed employee of an alarm agency discharges a weapon on duty. By when must a copy of the discharge report, on the Department's form, be filed with the Department?

    Answer: Within 15 days of the incident

    Section 35-30(e) requires the employer to keep a record of each discharge in the armed employee's permanent file on a Department form and file a copy with the Department within 15 days. Seventy-two hours is the time allowed to return an employer-issued firearm and the firearm control card after termination (Section 10-30(1)).

    Reference: Private Detective, Private Alarm, Private Security, Fingerprint Vendor, and Locksmith Act of 2004 (225 ILCS 447), 225 ILCS 447/35-30(e)

  4. A fire alarm control panel is being powered from a 120-volt branch circuit in a commercial building. Which statement about that branch circuit is correct under Article 760?

    Answer: It must supply no other loads and must not be fed through a GFCI or AFCI device

    Section 760.41(B) (non-power-limited) and 760.121(B) (power-limited) require a dedicated branch circuit that supplies no other loads and is not supplied through ground-fault or arc-fault circuit interrupters. A nuisance trip would silently remove primary power from the system, and a shared circuit invites someone to switch it off.

    Reference: NFPA 70, National Electrical Code, 2023, 760.41(B); 760.121(B)

  5. How must the circuit disconnecting means for a fire alarm branch circuit be identified?

    Answer: With red identification, accessible only to qualified personnel, marked "FIRE ALARM CIRCUIT"

    Sections 760.41(B)(4) and 760.121(B)(4) call for red identification, access limited to qualified personnel, and the words "FIRE ALARM CIRCUIT". The red marking must not damage the overcurrent device or hide the manufacturer's markings, and the disconnect may be secured in the "on" position.

    Reference: NFPA 70, National Electrical Code, 2023, 760.121(B)

  6. A non-power-limited fire alarm circuit is wired with 16 AWG conductors. Under Section 760.43, what is the maximum overcurrent protection for those conductors, absent an exception from another article?

    Answer: 10 amperes

    Section 760.43 caps overcurrent protection at 7 amperes for 18 AWG conductors and 10 amperes for 16 AWG conductors. For 14 AWG and larger, protection is based on conductor ampacity without applying the adjustment and correction factors of 310.14. The 7 ampere figure is the 18 AWG limit and 15 amperes is the usual 14 AWG limit.

    Reference: NFPA 70, National Electrical Code, 2023, 760.43

  7. Circuit integrity (CI) fire alarm cable is installed on a ceiling in a corridor, more than 7 feet above the floor. What is the maximum support spacing for the CI cable under Section 760.24(B)?

    Answer: 24 inches

    Section 760.24(B) limits support of circuit integrity cables to 610 mm (24 in.). Where the cable is within 2.1 m (7 ft) of the floor in the situations referenced, fastening is at intervals of not more than 450 mm (18 in.). Cable supports and fasteners for CI cable must be steel.

    Reference: NFPA 70, National Electrical Code, 2023, 760.24(B)

  8. Which document is written as a guide of recommendations for planning premises security, such as risk assessment and security measures, rather than as the installation standard for security alarm equipment?

    Answer: NFPA 730, Guide for Premises Security

    NFPA 730 is a guide: it recommends security planning and construction, protection and operational measures. NFPA 731 is the standard for installing electronic premises security systems (intrusion detection, access control, video and similar). NFPA 72 covers fire alarm and signaling, and NFPA 101 covers life safety.

    Reference: NFPA 730, Guide for Premises Security, 2023, Concept: NFPA 730 as a premises security guide (section numbers not available)

  9. Which location is most likely to cause false alarms from a PIR motion detector?

    Answer: Aimed at a sunny window or a space heater vent, where rapid heat changes occur

    Heat sources, sunlight and moving warm air create the same infrared changes as an intruder. Mount PIR detectors away from vents, heaters, direct sunlight and reflective surfaces, on a stable surface, at the manufacturer's height, aimed so the intruder crosses the zones.

    Reference: NFPA 731, Standard for Installation of Electronic Premises Security Systems, 2023, Concept: intrusion detection devices (PIR placement; section numbers not available)

  10. A burglar alarm uses a 12-volt 7 Ah battery. The control panel and sensors draw 0.35 A in standby. How long can the battery carry the load if only 80 percent of its rated capacity is considered usable?

    Answer: 16 hours

    Usable capacity = 7 Ah x 0.80 = 5.6 Ah. Time = 5.6 Ah / 0.35 A = 16 hours. Using the full 7 Ah gives 20 hours, which overstates what an aged battery delivers. The 24-hour figure is a fire alarm requirement, not a calculation result for this panel.

    Reference: NFPA 731, Standard for Installation of Electronic Premises Security Systems, 2023, Concept: power supplies (standby battery capacity; section numbers not available)

Sources

Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.