Requirements at a glance
| Agency | City of Chicago Department of Buildings; exam by Continental Testing Services (CTS) |
|---|---|
| Experience | Age 21 and 2 years of experience, with a letter from a Chicago supervising electrician |
| Exam | 150 questions, 4 hours, 70 to pass |
| Book allowed | Clean printed 2018 Chicago Electrical Code only; tabs allowed, no notes or highlighting |
| Fee | $150 (CTS); not refundable |
Electricians applying to the City of Chicago Department of Buildings for a supervising electrician license. You need to be 21 with 2 years of experience, shown by a letter from a Chicago supervising electrician.
Official links
How to get licensed, step by step
Confirm the edition
CTS's guide names the 2018 Chicago Electrical Code (NEC 2017 with amendments). Chicago's code modernization (Phase 3, October 2026) may change this, so confirm the current edition with CTS and the Department of Buildings.
Continental Testing Services: City of Chicago exams (opens in a new tab)City of Chicago Department of Buildings: trade licenses (opens in a new tab)
Get your experience letter
You need a letter from a Chicago supervising electrician confirming your 2 years of experience.
City of Chicago Department of Buildings: trade licenses (opens in a new tab)
Register with CTS
Register for a scheduled CTS date. There are no make-up exams and no refunds.
Continental Testing Services: City of Chicago exams (opens in a new tab)
Pass with 70
Bring two No. 2 pencils and a non-programmable, non-printing calculator. A pass notice includes the licensure application.
City of Chicago Department of Buildings: trade licenses (opens in a new tab)
How to prepare
- Edition caveat: our questions follow the 2018 Chicago Electrical Code in CTS's study guide (NEC 2017 with Chicago amendments). Check with CTS and the Department of Buildings whether Chicago's code modernization has changed the tested edition.
- Over 75% of answers are in the Chicago Electrical Code, and 125 of the 150 questions come from it. Tab the 200s and 300s chapters first.
- CTS gives you a list of changes since the code was published; read it before the exam.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Chicago Electrical Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Chicago Electrical Code (2018 edition; NFPA 70 2017 with Chicago amendments)Essential
The only book allowed in the room, as a clean printed copy with tabs. Confirm the current edition with CTS and the Chicago Department of Buildings.
American Electrician's Handbook, 16th Edition (2013)
CTS reference for the electrical principles part. Not allowed in the exam room.
Official reference list (as published by the testing agency)
- 2018 Chicago Electrical Code (NFPA 70 2017 with Chicago amendments): a clean printed copy; tabs allowed, no notes or highlighting
- American Electrician's Handbook, 16th Edition (2013)
- 29 CFR 1926 (OSHA construction standards)
- CTS 'Selected Provisions of Titles 2, 4 and 13' of the Chicago Municipal Code
What's on the exam
Official content outline from Continental Testing Services (CTS) (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Fundamental concepts | 3 | |
| Blueprint reading | 3 | |
| Conductors/conduit/grounding | 4 | |
| Transformers delta and wye | 3 | |
| Power factor and volt-amps | 3 | |
| Service and voltage drops | 3 | |
| OSHA and workplace safety | 6 | |
| Titles 2, 4 and Chapter 13 (Code Supplement) | 9 | |
| General Provisions (090-110s) | 11 | |
| Wiring and Protection (200s) | 20 | |
| Wiring Methods and Materials (300s) | 24 | |
| Equipment for General Use (400s) | 13 | |
| Special Occupancies (500s) | 13 | |
| Special Equipment (600s) | 12 | |
| Special Conditions (700s) | 13 | |
| Communication Systems (800s) | 10 |
Exam day details
- Administered by Continental Testing Services (CTS) for the City of Chicago Department of Buildings.
- Fee: $150
- 150 questions in 4 hours; 70 to pass. Part I is 25 questions on electrical principles and safety; Part II is 125 questions on the Chicago Electrical Code. Our topic weights are midpoints of CTS's printed ranges.
- Open book, but only the 2018 Chicago Electrical Code (clean printed copy, tabs allowed, no notes or highlighting). CTS also gives you a list of changes since the code was published.
- Bring two sharpened No. 2 pencils and a non-programmable, non-printing, solar- or battery-powered calculator. No power source is provided.
- CTS says over 75% of answers are in the Chicago Electrical Code. Fees are not refundable and a missed exam is re-registered for the next date.
- Edition check: CTS's guide is dated 2018 and names the 2018 Chicago Electrical Code. Chicago has been phasing in a Construction Codes Modernization Ordinance (Phase 3 effective October 2026), so confirm the current code edition with CTS and the Chicago Department of Buildings before you buy books or test.
Note: CTS's guide lists the 2018 Chicago Electrical Code (NEC 2017 with amendments), and Chicago's code modernization changes (Phase 3, October 2026) may have updated the tested edition. Confirm the current edition with CTS and the Chicago Department of Buildings.
Frequently asked questions
Which code edition is on the Chicago supervising electrician exam?
CTS's study guide names the 2018 Chicago Electrical Code, which is NFPA 70 (NEC) 2017 with Chicago amendments. Chicago is changing its construction codes, so confirm the current edition with CTS and the Department of Buildings.
Is the Chicago supervising electrician exam open book?
Yes, but only the Chicago Electrical Code. You may tab it; notes and highlighting are not allowed.
What are the requirements?
Age 21 and 2 years of experience, with a letter from a Chicago supervising electrician. The exam fee is $150.
Free questions with answers
Show all 10 free questions and answers
Under the OSHA construction standard, at what height above a lower level must an employee on an unprotected side or edge of a walking/working surface be protected from falling?
Answer: 6 feet
29 CFR 1926.501(b)(1) requires fall protection (guardrails, safety nets or personal fall arrest systems) for each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level. The 4-foot figure is the general-industry trigger and 10 feet applies to scaffolds.
Reference: 29 CFR 1926 (OSHA construction standards), 1926.501(b)(1)
Before the Department of Buildings will issue an electrical contractor license in Chicago, what must the business do regarding a supervising electrician?
Answer: Appoint or employ a person who holds a valid supervising electrician license
Section 4-292-010 requires an electrical contractor to appoint or employ a person holding a valid supervising electrician license before any license under Chapter 4-290 is issued, and 4-290-030 requires the application to state that supervising electrician's name. Chicago now licenses electrical contractors (Class 1 or Class 2) rather than registering them.
Reference: Municipal Code of Chicago (2026, amlegal S-75), 4-292-010; 4-290-030
For a circuit rated 100 amperes or less, or marked for 14 AWG through 1 AWG conductors, what termination temperature rating is assumed unless the equipment is listed and identified otherwise?
Answer: 60 degrees C
Section 110.14(C)(1)(a) requires conductors for such circuits to be selected from the 60 C ampacity column unless the equipment is listed and identified for a higher temperature, such as 75 C. A 90 C conductor may be used for ampacity correction and adjustment, but the final ampacity cannot exceed the termination rating.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 110.14(C)(1)(a)
In the habitable rooms of a dwelling unit, how far apart may wall receptacles be spaced along the floor line, measured so no point along the wall is too far from an outlet?
Answer: No point along the floor line may be more than 6 feet from a receptacle
Section 210.52(A)(1) requires receptacles so located that no point along the wall line is more than 6 ft, measured horizontally, from a receptacle. This is the origin of the familiar 12-ft maximum spacing between outlets.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 210.52(A)(1)
What is the minimum cover for rigid PVC conduit direct-buried under a lawn, in a 480-volt circuit (not a dwelling branch-circuit exception)?
Answer: 18 inches
Table 300.5 column 3 (nonmetallic raceways listed for direct burial without concrete encasement) lists 18 in. of cover. 6 in. is for rigid metal conduit and IMC (column 2), and 24 in. is for direct-buried cable (column 1).
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), Table 300.5
In which of these dwelling unit locations are 15- and 20-ampere, 125- and 250-volt receptacles required by the 2017 NEC to be tamper-resistant?
Answer: Kitchen countertop receptacles
Section 406.12 requires listed tamper-resistant receptacles in the areas specified in 210.52 for dwelling units, which includes kitchen countertops, along with guest rooms, child care facilities, preschools and similar. Exceptions cover receptacles over 5-1/2 ft, those in a dedicated space for an appliance and those part of a luminaire or appliance.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 406.12
Under the Class I, Division 1 sealing rules, how close to an explosionproof enclosure containing arcing or sparking devices must a conduit seal be located, for an entry of trade size 2 inch or smaller?
Answer: Within 18 inches of the enclosure
Section 501.15(A)(1) requires a seal in each conduit entry into an explosionproof enclosure containing apparatus that may produce arcs, sparks or high temperatures, located not more than 450 mm (18 in.) from the enclosure. Seals also keep gases and vapors from traveling through the conduit.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 501.15(A)(1)
Where must the disconnecting means for a sign or outline lighting system be located?
Answer: Within sight of the sign or outline lighting it controls
Section 600.6(A) requires each sign and outline lighting system to have a disconnecting means, externally operable and located within sight of the sign it controls (or capable of being locked in the open position where not within sight, as allowed in 600.6(A)(1)).
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 600.6(A)
Under the Chicago Electrical Code, unit battery equipment for emergency illumination must keep at least 87-1/2 percent of nominal battery voltage for its lamp load for at least how long?
Answer: 1-1/2 hours
Chicago 700.66(C)(1)(e) (14E-7-700) requires unit battery equipment to keep not less than 87-1/2 percent of nominal battery voltage for the total lamp load for at least 90 minutes (1-1/2 hours). The 4-hour figure is Chicago's duration for the final reserve source (700.50) and for inverter systems in high-rise buildings and large assembly occupancies (700.33(I)), not for unit equipment.
Reference: Chicago Electrical Code (NFPA 70-2017 as amended by Municipal Code of Chicago Title 14E), 14E-7-700 (700.66(C)(1)(e))
How many intersystem bonding conductors must the intersystem bonding termination provide a connection for, at a minimum, under the 2017 NEC?
Answer: At least three
Section 250.94 requires an intersystem bonding termination for connecting communications and other systems to the grounding electrode system with a set of terminals that can accept at least three intersystem bonding conductors, accessible for connection and inspection. It is located at the service equipment or metering equipment enclosure.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 250.94