Requirements at a glance
| Agency | City of Chicago Department of Buildings; exam by Continental Testing Services (CTS) |
|---|---|
| Experience | Age 21 and 2 years of experience in your license category, with a letter from a Chicago supervising electrician |
| Exam | 100 questions, 3 hours, 70 to pass: 25 on electrical principles and 75 on the Chicago Electrical Code |
| Book allowed | Clean printed 2018 Chicago Electrical Code only; tabs allowed, no notes or highlighting |
| Fee | $150 (CTS); not refundable |
Electricians applying to the City of Chicago Department of Buildings for a supervising low voltage electrician license. You need to be 21 with 2 years of experience in your license category, shown by a letter from a Chicago supervising electrician.
Official links
How to get licensed, step by step
Confirm the edition
CTS's guide names the 2018 Chicago Electrical Code (NEC 2017 with amendments). Chicago's code modernization (Phase 3, October 2026) may change this, so confirm the current edition with CTS and the Department of Buildings.
Continental Testing Services: City of Chicago exams (opens in a new tab)City of Chicago Department of Buildings: trade licenses (opens in a new tab)
Get your experience letter
You need a letter from a Chicago supervising electrician with an active license confirming 2 years of experience in your license category.
City of Chicago Department of Buildings: trade licenses (opens in a new tab)
Register with CTS
Register for a scheduled CTS date. There are no make-up exams and no refunds.
Continental Testing Services: City of Chicago exams (opens in a new tab)
Pass with 70
Bring two No. 2 pencils and a non-programmable, non-printing calculator. A pass notice includes the licensure application.
CTS: Chicago Supervising Electrician study guide (2018) (opens in a new tab)
How to prepare
- Edition caveat: our questions follow the 2018 Chicago Electrical Code in CTS's study guide (NEC 2017 with Chicago amendments). Check with CTS and the Department of Buildings whether Chicago's code modernization has changed the tested edition.
- Part I (25 questions) is the same electrical principles and safety content as the supervising electrician exam. Part II is 75 code questions; the 300s wiring methods and the 200s and 800s chapters carry the most weight.
- Use only the Chicago Electrical Code in the room; tab the chapters you expect to use most.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Chicago Electrical Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Chicago Electrical Code (2018 edition; NFPA 70 2017 with Chicago amendments)Essential
The only book allowed in the room, as a clean printed copy with tabs. Confirm the current edition with CTS and the Chicago Department of Buildings.
American Electrician's Handbook, 16th Edition (2013)
CTS reference for the electrical principles part. Not allowed in the exam room.
Official reference list (as published by the testing agency)
- 2018 Chicago Electrical Code (NFPA 70 2017 with Chicago amendments): a clean printed copy; tabs allowed, no notes or highlighting
- American Electrician's Handbook, 16th Edition (2013)
- 29 CFR 1926 (OSHA construction standards)
- CTS 'Selected Provisions of Titles 2, 4 and 13' of the Chicago Municipal Code
What's on the exam
Official content outline from Continental Testing Services (CTS) (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Fundamental concepts | 3 | |
| Blueprint reading | 3 | |
| Conductors/conduit/grounding | 4 | |
| Transformers delta and wye | 3 | |
| Power factor and volt-amps | 3 | |
| Service and voltage drops | 3 | |
| OSHA and workplace safety | 6 | |
| Titles 2, 4 and Chapter 13 (Code Supplement) | 6 | |
| General Provisions (090-110s) | 6 | |
| Wiring and Protection (200s) | 10 | |
| Wiring Methods and Materials (300s) | 15 | |
| Equipment for General Use (400s) | 7 | |
| Special Occupancies (500s) | 7 | |
| Special Equipment (600s) | 7 | |
| Special Conditions (700s) | 7 | |
| Communication Systems (800s) | 10 |
Exam day details
- Administered by Continental Testing Services (CTS) for the City of Chicago Department of Buildings.
- Fee: $150
- 100 questions in 3 hours; 70 to pass. Part I is 25 questions on electrical principles and safety (same as the supervising electrician exam); Part II is 75 questions on the Chicago Electrical Code. Our topic weights are chosen within CTS's printed ranges.
- Open book, but only the Chicago Electrical Code (clean printed copy, tabs allowed, no notes or highlighting), the same book as the supervising electrician exam.
- Bring two sharpened No. 2 pencils and a non-programmable, non-printing, solar- or battery-powered calculator. No power source is provided.
- Fees are not refundable and a missed exam is re-registered for the next date.
- Edition check: CTS's guide is dated 2018 and names the 2018 Chicago Electrical Code. Chicago has been phasing in a Construction Codes Modernization Ordinance (Phase 3 effective October 2026), so confirm the current code edition with CTS and the Chicago Department of Buildings before you buy books or test.
Note: CTS's guide lists the 2018 Chicago Electrical Code (NEC 2017 with amendments), and Chicago's code modernization changes (Phase 3, October 2026) may have updated the tested edition. Confirm the current edition with CTS and the Chicago Department of Buildings.
Frequently asked questions
Which code edition is on the Chicago low voltage electrician exam?
CTS's study guide names the 2018 Chicago Electrical Code, which is NFPA 70 (NEC) 2017 with Chicago amendments. Chicago is changing its construction codes, so confirm the current edition with CTS and the Department of Buildings.
How is it different from the supervising electrician exam?
It has 100 questions in 3 hours instead of 150 in 4. Part I (25 questions) is the same; Part II has 75 Chicago Electrical Code questions with more weight on communication systems (800s).
Is it open book?
Yes, but only the Chicago Electrical Code. You may tab it; notes and highlighting are not allowed.
Free questions with answers
Show all 10 free questions and answers
An electrical contractor's supervising electrician is replaced. By what deadline must the contractor file an amended application with the Commissioner?
Answer: Within 5 days of the change in supervising electrician
Section 4-290-055 requires notice of a change in company name, address or ownership within 30 days, but a change in supervising electrician within 5 days, by filing an amended application. Do not mix up the two periods; the 30-day period is the tempting wrong answer.
Reference: Municipal Code of Chicago (2026, amlegal S-75), 4-290-055
A non-self-supporting portable ladder has a working length of 16 feet. About how far from the vertical wall should its base be placed?
Answer: 4 feet
Under 29 CFR 1926.1053(b)(5)(i), a non-self-supporting ladder is positioned so the horizontal distance from the base to the support is about one-quarter of the working length. 16 / 4 = 4 ft.
Reference: 29 CFR Part 1926 (OSHA Safety and Health Regulations for Construction), 1926.1053(b)(5)(i)
What is the maximum overcurrent protection for a 14 AWG copper conductor in a general-use branch circuit (not a motor or air-conditioning circuit)?
Answer: 15 amperes
Section 240.4(D)(3) limits 14 AWG copper to 15 A, 12 AWG copper to 20 A (240.4(D)(5)) and 10 AWG copper to 30 A (240.4(D)(7)). The 20 A figure belongs to 12 AWG, and 25 A is not a limit for a small conductor.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 240.4(D)(3)
A listed device is to be mounted in a way that the instructions in its listing do not allow. What does the NEC require?
Answer: Install and use it per the listing or labeling instructions
Section 110.3(B) says listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. Field changes outside those instructions can void the listing.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 110.3(B)
A rigid PVC conduit with 480-volt feeder conductors is direct-buried under a commercial parking lot. What is the minimum cover from Table 300.5?
Answer: 24 inches
Table 300.5 requires 24 in. of cover for nonmetallic raceways listed for direct burial under streets, highways, roads, alleys, driveways and parking lots. The 18 in. figure is for the general case with no vehicle traffic, and 6 in. applies to rigid metal conduit.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), Table 300.5
A panelboard that is not used as service equipment has no single main; instead it is protected by main breakers on its supply side. Under the 408.36 exception that allows this, what is the limit on those mains?
Answer: No more than two mains, with combined rating not above the panelboard rating
Section 408.36 requires a panelboard to be protected by an overcurrent device rated not more than the panelboard. An exception waives individual protection for a panelboard (other than service equipment) protected by two main circuit breakers or two sets of fuses whose combined rating is not greater than the panelboard rating; such a panelboard may contain no more than 42 overcurrent devices. Six disconnects is the service count in 230.71, not this rule.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 408.36 Exception (two main circuit breakers)
In a major repair garage for vehicles fueled with gasoline, the room has no floor-level ventilation. Up to what height above the floor is the entire floor area classified as Class I, Division 2?
Answer: 18 inches
Section 511.3(C) and Table 511.3(C) (repair garages for Class I liquids or heavier-than-air fuels) classify the entire floor area of a major repair garage up to 450 mm (18 in.) above the floor as Class I, Division 2. That zone becomes unclassified only where ventilation of at least 1 cfm per square foot of floor area is provided with suction within 12 in. of the floor. The 3 ft figure is the zone around a fill or dispensing point.
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 511.3(C); Table 511.3(C)
Where must the disconnecting means for a sign or outline lighting system be located?
Answer: Within sight of the sign it controls, or lockable open where it is not
Section 600.6(A) requires each sign and outline lighting system to have an externally operable disconnecting means. It must be within sight of the sign it controls, or capable of being locked in the open position where it is not within sight (600.6(A)(1)).
Reference: NFPA 70, National Electrical Code, 2017 (basis of the 2018 Chicago Electrical Code), 600.6(A)
Where must a sign identifying the type and location of on-site emergency power sources generally be placed?
Answer: At the service-entrance equipment
Chicago replaces NEC Article 700 with its own text. Chicago 700.25(A) requires a sign at the service-entrance equipment indicating the type and location of each on-site emergency power source; the only exception is individual unit battery equipment under 700.43. A sign is not required at each luminaire, the telephone demarcation or the roof.
Reference: Chicago Electrical Code (NFPA 70-2017 as amended by Municipal Code of Chicago Title 14E), 14E-7-700 (700.25(A))
Which communications cable type carries the listing for use in ducts, plenums and other spaces used for environmental air (the highest fire-resistance listing)?
Answer: Type CMP
The listing requirements (800.179, not amended by Chicago) rank communications cable as CMP for plenums, CMR for risers, CMG or CM for general-purpose use and CMX for limited use, so CMP carries the plenum listing; CMR is riser rated only. In Chicago, however, revised 800.113(B) and (C) and Table 800.154(a) do not permit any communications cable, CMP included, to run exposed in fabricated ducts or plenums: it must be in metal raceway complying with 300.22(B) or (C).
Reference: Chicago Electrical Code (NFPA 70-2017 as amended by Municipal Code of Chicago Title 14E), 14E-8-800 (800.113(B)-(C); Table 800.154(a))