Idaho HVAC Specialty Journeyman Exam: Practice Test & Licensing Guide

Idaho's HVAC specialty journeyman exam, given by PSI: 50 questions on the 2018 International Fuel Gas Code as Idaho adopted it. Open book, 2 hours, 70% to pass.

Questions
50
Time limit
2 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10IFGC Chapter 1: Scope and Administration

A contractor is installing natural gas piping for an industrial process building in Idaho. Under IFGC 101.2.2, up to what maximum operating pressure does the fuel gas code cover natural gas piping systems?

Requirements at a glance

AgencyIdaho Division of Occupational and Professional Licenses (DOPL); exam by PSI
Exam50 questions (IFGC only), 2 hours, 70% to pass
Book allowed2018 International Fuel Gas Code
Fees$75 per exam to PSI, plus DOPL license fees

Installers applying to Idaho DOPL for an HVAC specialty journeyman license. The exam covers fuel gas only; the full HVAC journeyman exam adds the mechanical code.

How to get licensed, step by step

  1. Finish your training

    Complete the training or experience DOPL requires for the HVAC specialty journeyman license.

    DOPL: HVAC program (opens in a new tab)

  2. Register and pay with PSI

    Create a PSI account, pick the Idaho HVAC Specialty Journeyman exam, pay the $75 fee and book a seat.

    Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)DOPL: HVAC program exams (opens in a new tab)

  3. Apply to DOPL

    After you pass, apply through eDOPL for the license.

    DOPL online license application (eDOPL) (opens in a new tab)

How to prepare

  • Get the 2018 edition of the IFGC; newer editions moved and changed sections.
  • Gas piping (Chapter 4) is 9 questions and chimneys and vents (Chapter 5) 8. Tab the pipe sizing tables.
  • Idaho amends IFGC 406.4 (gas piping test pressure and a 20-minute test). Know the Idaho numbers as well as the model code's.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IFGC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • 2018 International Fuel Gas Code (IFGC), ICC

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
IFGC Chapter 1: Scope and Administration6
IFGC Chapter 2: Definitions6
IFGC Chapter 3: General Regulations7
IFGC Chapter 4: Gas Piping Installations9
IFGC Chapter 5: Chimneys and Vents8
IFGC Chapter 6: Specific Appliances7
IFGC Chapter 7: Gaseous Hydrogen Systems7

Exam day details

  • Administered by PSI Services for the Idaho Division of Occupational and Professional Licenses (DOPL).
  • Fee: $75 per exam, paid to PSI when you schedule. The fee is good for one year, isn't refundable, and each retake costs it again. DOPL license application fees are separate.
  • 50 questions in 2 hours; 70% to pass. Every question comes from the 2018 IFGC.
  • Idaho adopted the 2018 IFGC with amendments (IDAPA 24.39.70). One to know: Idaho sets its own gas piping test pressures and a 20-minute test duration in IFGC 406.4.
  • You may highlight, underline and add permanent tabs to your references, but not write in them. Sticky notes and loose papers aren't allowed.
  • Your score shows on screen when you finish.
  • Cancel or reschedule at least 2 days before your appointment to keep your fee.

Frequently asked questions

What's on the Idaho HVAC specialty journeyman exam?

Per DOPL's December 2025 PSI bulletin, 50 IFGC questions: gas piping installations 9, chimneys and vents 8, general regulations 7, specific appliances 7, gaseous hydrogen systems 7, administration 6 and definitions 6.

Which code book do I bring?

Only the 2018 International Fuel Gas Code. Newer editions number some sections differently, so bring the 2018 book.

Free questions with answers

Show all 10 free questions and answers
  1. A contractor is installing natural gas piping for an industrial process building in Idaho. Under IFGC 101.2.2, up to what maximum operating pressure does the fuel gas code cover natural gas piping systems?

    Answer: 125 psig

    Section 101.2.2 covers natural gas piping with an operating pressure of 125 psig or less, and LP-gas piping at 20 psig or less. 20 psig is the LP-gas limit, not the natural gas limit. 60 psig is Idaho's 406.4.1 test pressure for systems between 10 in. w.c. and 10 psig, not a scope limit.

    Reference: 2018 International Fuel Gas Code (Idaho), 101.2.2

  2. For an undiluted LP-gas system serving a rural home's appliances, where is the point of delivery under IFGC Chapter 2?

    Answer: Outlet of the service pressure regulator

    For undiluted LP-gas systems, Chapter 2 places the point of delivery at the outlet of the service pressure regulator, exclusive of line gas pressure regulators. The first-stage regulator is upstream of the service regulator. For natural gas the point of delivery is the outlet of the service meter assembly (or of the service regulator or service shutoff valve where no meter is provided).

    Reference: 2018 International Fuel Gas Code (Idaho), 202 (Point of Delivery)

  3. An 80,000 Btu/h furnace and a 50,000 Btu/h water heater share a mechanical room that will get all combustion air from indoors using the standard method of IFGC 304.5.1. What minimum indoor air volume is required?

    Answer: 6,500 cubic feet

    The standard method requires 50 cubic feet per 1,000 Btu/h of total appliance input in the space. Total input = 80,000 + 50,000 = 130,000 Btu/h; 130 x 50 = 6,500 cubic feet. 4,000 cubic feet counts only the furnace (80 x 50), and 13,000 uses 100 cubic feet per 1,000 Btu/h. Section 304.5.2 (known infiltration rate) must be used instead if infiltration is known to be under 0.40 ACH.

    Reference: 2018 International Fuel Gas Code (Idaho), 304.5, 304.5.1

  4. A furnace closet will use the one-permanent-opening method of IFGC 304.6.2 for outdoor combustion air. What minimum clearances must the furnace have within the enclosure?

    Answer: 1 inch at the sides and back and 6 inches at the front

    Section 304.6.2 requires the appliance to have clearances of at least 1 inch from the sides and back and 6 inches from the front when a single opening is used. The opening must start within 12 inches of the top of the enclosure and have 1 square inch per 3,000 Btu/h of total input, but not less than the sum of the vent connector areas. The other choices reverse or inflate these numbers.

    Reference: 2018 International Fuel Gas Code (Idaho), 304.6.2

  5. A new gas piping system with a maximum working pressure of 5 psig is to be air tested in Idaho. Which test meets Idaho's amended IFGC 406.4.1 and 406.4.2 minimums?

    Answer: 60 psig for 20 minutes

    Under Idaho's 406.4.1, systems with a maximum working pressure between 10 in. w.c. and 10 psig must be tested at not less than 60 psig, and Idaho's 406.4.2 sets a minimum duration of 20 minutes. 20 psig is Idaho's minimum only for systems up to 10 in. w.c., so 20 psig fails here even for 30 minutes. 7.5 psig (1.5 times working pressure) and 10-minute durations do not meet the Idaho amendments.

    Reference: 2018 International Fuel Gas Code (Idaho), 406.4.1, 406.4.2 (Idaho)

  6. A condensing furnace in a new Idaho home is vented with plastic pipe. Under the section Idaho added to the IFGC (503.4.1.2), what test is required on the plastic flue gas vent pipe within the dwelling?

    Answer: 5 psi for 15 minutes

    IDAPA 24.39.70.600.02.e adds IFGC 503.4.1.2: all plastic pipe within a dwelling used for venting flue gases must be tested at 5 psi for 15 minutes. 20 psig for 20 minutes is Idaho's gas piping test (406.4.1 and 406.4.2) for systems up to 10 in. w.c., not a vent test. Idaho adds the same vent test to the IRC as G2427.4.1.2.

    Reference: 2018 International Fuel Gas Code (Idaho), 503.4.1.2 (Idaho)

  7. A sidewall vent terminal for a furnace is planned near an exterior door. Under IFGC 502.7.1, the terminal must be located so the door cannot swing within what horizontal distance of it?

    Answer: 12 inches

    Section 502.7.1 requires vent terminals to be located so doors cannot swing within 12 inches horizontally of the terminal, and door stops or closers may not be used to obtain that clearance. The same 12-inch door-swing rule applies to wall furnace air openings in 608.4.

    Reference: 2018 International Fuel Gas Code (Idaho), 502.7.1

  8. Under IFGC 621.3, what is the maximum input rating permitted for an unvented room heater?

    Answer: 40,000 Btu/h

    Section 621.3 limits unvented room heaters to an input rating of 40,000 Btu/h. 10,000 Btu/h is the limit for a single wall-mounted unvented room heater in a bedroom under 303.3 (6,000 Btu/h in a bathroom). Unvented room heaters also may not be the sole source of comfort heat in a dwelling unit (621.2).

    Reference: 2018 International Fuel Gas Code (Idaho), 621.3

  9. A den measures 11 ft by 13 ft with an 8 ft ceiling and opens through an archway that cannot be closed into a reading nook 5 ft by 9 ft with an 8 ft ceiling. Under IFGC 621.5, what is the maximum aggregate input of all unvented appliances that may be installed in the den?

    Answer: 30,080 Btu/h

    Section 621.5 limits the aggregate input of unvented appliances to 20 Btu/h per cubic foot of room volume and lets you include an adjacent space connected by an opening that cannot be closed. Den = 11 x 13 x 8 = 1,144 cubic feet; nook = 5 x 9 x 8 = 360 cubic feet; total 1,504 x 20 = 30,080 Btu/h. 22,880 Btu/h ignores the nook, 15,040 uses 10 Btu/h per cubic foot, and 40,000 Btu/h is the 621.3 cap for one heater.

    Reference: 2018 International Fuel Gas Code (Idaho), 621.5

  10. Before a hydrogen fuel-cell supply line operating at 40 psig is placed in service, the installer chooses a hydrostatic (water) leak test. Under IFGC 705.3.1, what is the minimum test pressure?

    Answer: 100 psig

    Section 705.3.1 requires the hydrostatic test pressure to be at least 1.5 times the maximum working pressure and not less than 100 psig. 1.5 x 40 = 60 psig, which is below the 100 psig floor, so 100 psig governs. 44 psig (110 percent) applies only to pneumatic tests at working pressures of 125 psig or more.

    Reference: 2018 International Fuel Gas Code (Idaho), 705.3.1