Requirements at a glance
| Agency | Idaho Division of Occupational and Professional Licenses (DOPL); exam by PSI |
|---|---|
| Exam | 100 questions (63 IMC, 37 IFGC), 4 hours, 70% to pass |
| Books allowed | 2018 International Mechanical Code and 2018 International Fuel Gas Code |
| Fees | $75 per exam to PSI, plus DOPL license fees |
HVAC installers applying to Idaho DOPL for an HVAC journeyman license. You pass the exam with PSI, then apply to DOPL with your apprenticeship or experience.
Official links
How to get licensed, step by step
Finish your training
Complete the apprenticeship or experience DOPL requires for an HVAC journeyman license.
Register and pay with PSI
Create a PSI account, pick the Idaho HVAC Journeyman exam, pay the $75 fee and book a seat.
Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)DOPL: HVAC program exams (opens in a new tab)
Pass the exam
Bring your tabbed 2018 IMC and IFGC.
Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)
Apply to DOPL
After you pass, apply through eDOPL for the journeyman license.
DOPL online license application (eDOPL) (opens in a new tab)
How to prepare
- Get the 2018 editions. The 2021 and 2024 codes moved and changed sections, and the exam is written to 2018.
- IMC general regulations (Ch. 3) and exhaust systems (Ch. 5) are 9 questions each; in the IFGC, chimneys and vents (Ch. 5) is 8 and gas piping (Ch. 4) is 7.
- Idaho amends IFGC 406.4 (gas piping test pressure and a 20-minute test). Know the Idaho numbers as well as the model code's.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 IMC and the 2018 IFGC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 International Mechanical Code (IMC)Essential
63 of the 100 journeyman questions. Bring the 2018 edition; tab Chapters 3, 5 and 11.
ICC store (opens in a new tab)Read free (opens in a new tab)
2018 International Fuel Gas Code (IFGC)Essential
37 of the 100 journeyman questions. Gas pipe sizing tables (Chapter 4), venting (Chapter 5) and appliances (Chapter 6). Note Idaho's 406.4 test pressure amendment.
ICC store (opens in a new tab)Read free (opens in a new tab)
Official reference list (as published by the testing agency)
- 2018 International Mechanical Code (IMC), ICC
- 2018 International Fuel Gas Code (IFGC), ICC
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| IMC Chapter 1: Scope and Administration | 4 | |
| IMC Chapter 2: Definitions | 7 | |
| IMC Chapter 3: General Regulations | 9 | |
| IMC Chapter 4: Ventilation | 5 | |
| IMC Chapter 5: Exhaust Systems | 9 | |
| IMC Chapter 6: Duct Systems | 4 | |
| IMC Chapter 8: Chimneys and Vents | 4 | |
| IMC Chapter 9: Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment | 3 | |
| IMC Chapter 10: Boilers, Water Heaters and Pressure Vessels | 3 | |
| IMC Chapter 11: Refrigeration | 5 | |
| IMC Chapter 12: Hydronic Piping | 5 | |
| IMC Chapter 13: Fuel Oil Piping and Storage | 4 | |
| IMC Chapter 14: Solar Thermal Systems | 1 | |
| IFGC Chapter 1: Scope and Administration | 3 | |
| IFGC Chapter 2: Definitions | 3 | |
| IFGC Chapter 3: General Regulations | 6 | |
| IFGC Chapter 4: Gas Piping Installations | 7 | |
| IFGC Chapter 5: Chimneys and Vents | 8 | |
| IFGC Chapter 6: Specific Appliances | 5 | |
| IFGC Chapter 7: Gaseous Hydrogen Systems | 5 |
Exam day details
- Administered by PSI Services for the Idaho Division of Occupational and Professional Licenses (DOPL).
- Fee: $75 per exam, paid to PSI when you schedule. The fee is good for one year, isn't refundable, and each retake costs it again. DOPL license application fees are separate.
- 100 questions in 4 hours; 70% to pass. 63 questions come from the IMC and 37 from the IFGC.
- Idaho adopted the 2018 IMC and 2018 IFGC with amendments (IDAPA 24.39.70). One to know: Idaho sets its own gas piping test pressures and a 20-minute test duration in IFGC 406.4.
- Pass the exam with PSI, then apply to DOPL.
- You may highlight, underline and add permanent tabs to your references, but not write in them. Sticky notes and loose papers aren't allowed.
- Your score shows on screen when you finish.
- Cancel or reschedule at least 2 days before your appointment to keep your fee.
Frequently asked questions
What's on the Idaho HVAC journeyman exam?
Per DOPL's December 2025 PSI bulletin, 63 IMC questions (general regulations 9, exhaust 9, definitions 7, ventilation 5, refrigeration 5, hydronics 5, administration, ducts, chimneys and vents, and fuel oil 4 each, specific appliances and boilers 3 each, solar 1) and 37 IFGC questions (chimneys and vents 8, gas piping 7, general regulations 6, specific appliances 5, hydrogen 5, administration 3, definitions 3).
Which code books do I bring?
The 2018 International Mechanical Code and the 2018 International Fuel Gas Code. Newer editions number some sections differently, so bring the 2018 books.
Do I need EPA 608 too?
If you handle refrigerant, yes. EPA 608 is a separate federal certification; the Idaho HVAC license doesn't replace it.
Free questions with answers
Show all 10 free questions and answers
Idaho amends the IMC Section 202 definitions of cooking appliance duty classifications. Under the Idaho amendment, where is a gas conveyor pizza oven classified?
Answer: Light-duty cooking appliance
IDAPA 24.39.70.600 amends Section 202 by adding conveyorized pizza to the light-duty oven definition and removing electric and gas conveyor pizza ovens from the medium-duty definition. The duty class drives the type of exhaust hood and exhaust rates required in Chapter 5.
Reference: 2018 International Mechanical Code (Idaho), 202 (Light-Duty Cooking Appliance), IDAPA 24.39.70.600
A fuel-fired water heater without a flammable vapor ignition resistant listing is installed in a private garage. Under IMC 304.3, the ignition source must be at least how far above the floor?
Answer: 18 inches
IMC 304.3 requires equipment having an ignition source in garages and hazardous locations to be elevated so the ignition source is not less than 18 inches above the floor. The exception applies only to appliances listed as flammable vapor ignition resistant.
Reference: 2018 International Mechanical Code (Idaho), 304.3
Under IMC Table 401.5, what are the opening size limits for the screen or louver protecting an outdoor air intake in a residential occupancy?
Answer: Not less than 1/4 inch and not more than 1/2 inch
Table 401.5 limits openings in louvers, grilles and screens on residential intakes to between 1/4 and 1/2 inch. Other than residential occupancies the opening must be greater than 1/4 inch and not more than 1 inch. For rectangular openings the limit applies to the shortest side.
Reference: 2018 International Mechanical Code (Idaho), Table 401.5
Which of the following is required at the termination of a clothes dryer exhaust duct under IMC 504.4?
Answer: A backdraft damper, with no screen installed at the termination
IMC 504.4 requires dryer exhaust ducts to terminate outside the building with a backdraft damper. Screens must not be installed at the termination because lint clogs them, and the terminal must provide an open area of at least 12.5 square inches (504.4.1).
Reference: 2018 International Mechanical Code (Idaho), 504.4
Under IMC 1107.5.4, which joint type is required for copper tubing in a refrigerating system containing a Group A2 refrigerant?
Answer: Brazed joints; soldered joints are not permitted
IMC 1107.5.4 requires copper tubing joints in systems containing Group A2, A3, B2 or B3 refrigerants to be brazed, and soldered joints are not allowed. Joints erected on the premises must also be exposed for visual inspection before being covered (1107.7).
Reference: 2018 International Mechanical Code (Idaho), 1107.5.4
The flash point of the transfer fluid in a hydronic piping system must be at least how much higher than the maximum system operating temperature under IMC 1207.1?
Answer: 50°F
IMC 1207.1 requires the flash point of the transfer fluid to be not less than 50°F (28°C) above the maximum operating temperature of the system.
Reference: 2018 International Mechanical Code (Idaho), 1207.1
Under IFGC 304.6.1, where must the two permanent outdoor combustion air openings be located?
Answer: One within 12 inches of the top and one within 12 inches of the bottom of the enclosure
IFGC 304.6.1 requires two permanent openings, one commencing within 12 inches of the top and one within 12 inches of the bottom of the enclosure, communicating directly or by ducts with the outdoors. The minimum dimension of an opening is 3 inches (304.6).
Reference: 2018 International Fuel Gas Code (Idaho), 304.6.1
Idaho amends IFGC 406.4.1. What is the minimum test pressure for a fuel gas piping system whose maximum working pressure is 7 inches water column, and the minimum test duration under 406.4.2?
Answer: 20 psig for not less than 20 minutes
The Idaho amendments (IDAPA 24.39.70.600) require not less than 20 psig for systems with a maximum working pressure up to 10 inches water column, and a test duration of not less than 20 minutes. The 60 psig value applies to systems between 10 inches water column and 10 psig.
Reference: 2018 International Fuel Gas Code (Idaho), 406.4.1, 406.4.2 (Idaho)
A direct-vent appliance with an input of 100,000 Btu/h terminates through the wall. Under IFGC Table 503.8, what is the minimum clearance from the vent terminal to any air opening into the building?
Answer: 12 inches
Table 503.8 sets through-the-wall direct-vent clearances by input: 6 inches below 10,000 Btu/h, 9 inches for 10,000 to 50,000, 12 inches for over 50,000 to 150,000, and manufacturer's instructions above 150,000 Btu/h. A 100,000 Btu/h unit falls in the 12 inch row.
Reference: 2018 International Fuel Gas Code (Idaho), Table 503.8
Under IFGC 608.4, how close may a door be able to swing to the air inlet or outlet of a vented wall furnace, measured at right angles to the opening?
Answer: It must not swing within 12 inches, and doorstops or closers may not be used to obtain this clearance
IFGC 608.4 requires vented wall furnaces to be located so a door cannot swing within 12 inches of an air inlet or outlet, measured at right angles to the opening. Doorstops or door closers shall not be installed to obtain this clearance.
Reference: 2018 International Fuel Gas Code (Idaho), 608.4
Sources
- Idaho DOPL: Combined PSI Candidate Bulletin (effective 12.10.2025, PDF) (opens in a new tab)
- Idaho DOPL: HVAC program exams (opens in a new tab)
- PSI: Idaho contractor and trade exams (candidate bulletins) (opens in a new tab)
Questions last verified October 27, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.