Requirements at a glance
| Agency | Hawaii Board of Electricians and Plumbers (DCCA PVL); exams by PSI |
|---|---|
| Experience | Registered as a journey worker plumber for at least 2 years, or equivalent experience in the trade (HRS 448E-5(b)) |
| Exam | Master plumber: 80 questions, 3 hours, 70% |
| Books allowed | None; closed book |
| Fee | $90 to PSI, plus the Board's application and license fees |
Journey worker plumbers applying for a Hawaii master plumber license from the Board of Electricians and Plumbers.
Official links
How to get licensed, step by step
Apply to the Board
Send the Board of Electricians and Plumbers your application with proof of your experience. You can't register with PSI until it approves you.
Board of Electricians and Plumbers (opens in a new tab)Hawaii Revised Statutes chapter 448E (electricians and plumbers) (opens in a new tab)Hawaii Administrative Rules 16-80 (electricians and plumbers) (opens in a new tab)
Schedule the master plumber exam with PSI
Register online or call PSI at 833-333-4754. Your approval is good for 2 years and you can test as often as you like in that time.
Get licensed
PSI reports your result to the Board; follow the Board's instructions for the license fee and any remaining requirements.
How to prepare
- Hawaii's trade exams are PSI exams on specific editions: the 2020 NEC, the 2018 UPC, IMC, IFGC and IBC. Hawaii's state electrical code is older than the 2020 NEC, so study to the editions on PSI's bulletin, and check the bulletin again before test day.
- Contractor exams are closed book except C-13, where PSI provides the NEC. Electrician exams provide the NEC too. Plumber and other contractor exams allow no reference books.
- Excavation, general knowledge and regulations (18) is the largest section, ahead of drain, waste and vent, water supply and fixtures (10 each).
- Know the 2018 UPC chapters on drainage, venting, water supply and backflow prevention.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
2018 Uniform Plumbing Code (UPC), IAPMOEssential
On PSI's outline, closed book. Code questions are based only on this edition.
IAPMO store (opens in a new tab)Read free (IAPMO) (opens in a new tab)
Mathematics for Plumbers and Pipefitters, 8th Edition (2013), Delmar Cengage
On PSI's outline, closed book. Source of the plumbing math questions.
29 CFR Part 1926 (OSHA construction standards)
On PSI's outline, closed book. Safety questions.
Official reference list (as published by the testing agency)
- Uniform Plumbing Code (UPC), 2018 edition, IAPMO (not allowed in the exam room)
- Mathematics for Plumbers and Pipefitters, 8th edition, 2013, Delmar Cengage Learning (not allowed)
- 29 CFR Part 1926 (OSHA construction standards) (not allowed)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Drain, Waste and Vent Systems, including Pipe Sizing | 10 | |
| Water Supply and Distribution, including Pipe Sizing | 10 | |
| Backflow Prevention | 5 | |
| Storm and Roof Drainage | 3 | |
| Fixtures and Water Heaters | 10 | |
| Excavation, General Knowledge, and Regulations | 18 | |
| Fuel Gas Systems, including Pipe Sizing | 5 | |
| Safety OSHA | 3 | |
| Isometrics | 6 | |
| Sewer | 6 | |
| Plumbing Math | 4 |
Exam day details
- Administered by PSI Services for the Hawaii Board of Electricians and Plumbers.
- Fee: $90 to PSI. Board application and license fees are separate.
- 80 scored questions in 3 hours; 56 correct (70%) to pass. The exam is closed book.
- The Board must approve your application before you can register with PSI. Your eligibility lasts 2 years, and you can test as often as you like within it.
- PSI may add up to 10 unscored pretest questions; they do not count against your time.
- PSI provides an online calculator, or you can bring a silent, non-programmable one.
Frequently asked questions
What's on the Hawaii master plumber exam?
80 scored questions: excavation, general knowledge and regulations 18, drain, waste and vent 10, water supply and distribution 10, fixtures and water heaters 10, isometrics 6, sewer 6, backflow prevention 5, fuel gas 5, plumbing math 4, storm and roof drainage 3 and safety 3.
Which code edition is on the exam?
The 2018 Uniform Plumbing Code (IAPMO).
Is it closed book?
Yes.
Free questions with answers
Show all 10 free questions and answers
A building drain trench has been inspected and approved and is ready to be backfilled. How must the first part of the backfill around the piping be placed?
Answer: In thin layers up to 12 inches above the pipe, using clean earth free of stones and debris
Section 314.4 requires trenches to be backfilled in thin layers to 12 inches above the top of the piping with clean earth that has no stones, boulders, cinder fill, frozen earth, construction debris or other material that could damage the pipe or cause corrosion. Only after that may mechanical equipment such as bulldozers or graders complete the backfill to grade, and fill must be properly compacted.
Reference: 2018 Uniform Plumbing Code, Section 314.4
A building is connected to a public sewer. Under Section 714.3, which of these may NOT be connected to the public sewer or to a building sewer leading to it?
Answer: A septic tank, cesspool, seepage pit or drain field
Section 714.3 prohibits connecting any cesspool, septic tank, seepage pit or drain field to a public sewer or to a building sewer leading to a public sewer. Floor drains, building drains and standpipes are ordinary parts of the drainage system and are connected through traps and the rules of Chapter 7.
Reference: 2018 Uniform Plumbing Code, Section 714.3
A designer sizes a vent system so that no trap seal is exposed to excessive pressure change. What maximum pressure differential on the outlet side of a trap does Section 901.3 allow?
Answer: 1 inch of water column
Section 901.3 requires the vent system to be designed so a trap seal is not exposed to a pressure differential exceeding 1 inch water column on the outlet side of the trap. The 10 inch figure in Section 712.3 is a mercury column used for the air test, not a trap seal limit.
Reference: 2018 Uniform Plumbing Code, Section 901.3
A lawn sprinkler system has its own booster pump that can create backpressure, and the backflow device is installed on the potable supply upstream of that pump. Which device does Section 603.5.6.1 require?
Answer: A reduced-pressure principle assembly (RP)
Section 603.5.6.1 covers sprinkler and irrigation systems with pumps, pumping connections or auxiliary air tanks, or that can otherwise create backpressure. Where the backflow device is upstream of the source of backpressure, the only device listed is a reduced-pressure principle assembly (RP). The AVB, PVB and SVB in Section 603.5.6 are allowed only for systems with no pumps and no chemical injection, and Section 603.5.6.2 allows them again only where the device is downstream of a potable water supply pump.
Reference: 2018 Uniform Plumbing Code, Sections 603.5.6 and 603.5.6.1
A building supply has a pressure regulator with an integral check valve, and a storage water heater is installed. Where must the expansion tank be located under Section 608.3?
Answer: On the building side of the check valve or backflow preventer
Section 608.3 requires an approved, listed and adequately sized expansion tank (or equivalent device) on systems with a check valve, backflow preventer or other normally closed device that prevents dissipation of building pressure back into the main. The tank is installed on the building side of that device, sized per the manufacturer's instructions.
Reference: 2018 Uniform Plumbing Code, Section 608.3
A water heater (40,000 Btu/h) and a furnace (80,000 Btu/h) are in a utility room that gets its combustion air from the indoor space. Using the Standard Method in Section 506.2.1, what minimum volume of indoor air is required?
Answer: 6,000 cubic feet
Section 506.2.1 requires at least 50 cubic feet per 1,000 Btu/h, and Section 506.2 says the volume is the sum for all appliances in the space. Total input = 40,000 + 80,000 = 120,000 Btu/h. 120 x 50 = 6,000 cubic feet.
Reference: 2018 Uniform Plumbing Code, Sections 506.2 and 506.2.1
Under Section 1101.3, where may storm water NOT be drained?
Answer: Into sewers intended for sanitary drainage
Section 1101.3 prohibits draining storm water into sewers intended for sanitary drainage. Section 1101.2 directs roof and yard drainage to a separate storm sewer, to a combined sewer where no separate system is available, or to another approved place of disposal.
Reference: 2018 Uniform Plumbing Code, Sections 1101.2 and 1101.3
A trunk line serves a water heater (40,000 Btu/h), a range (65,000 Btu/h) and a dryer (35,000 Btu/h) on natural gas at 1,000 Btu/cu ft. The longest run is 48 feet. Table 1215.2(1) at 50 feet gives 151 CFH for 3/4 inch and 284 CFH for 1 inch pipe. What is the smallest trunk size?
Answer: 3/4 inch
Demand = (40,000 + 65,000 + 35,000) / 1,000 = 140 CFH. Section 1215.4 uses the row for the length or the next longer length, so 48 feet uses the 50 foot row. At 50 feet 3/4 inch carries 151 CFH, which exceeds 140, so 3/4 inch is enough. A 1 inch pipe is larger than needed and 1/2 inch carries far less than 140.
Reference: 2018 Uniform Plumbing Code, Section 1215.4; Table 1215.2(1)
A public restroom group on one horizontal branch at 1/4 inch per foot has three flushometer water closets (4 DFU each), two lavatories (1 each) and one urinal (2). Using Table 703.2, what is the smallest branch size?
Answer: 3 inches
Load = 3 x 4 + 2 x 1 + 2 = 16 drainage fixture units. A 2 inch horizontal drain is rated for only 8 units. A 3 inch horizontal drain carries 35 units with no more than three water closets (Table 703.2, footnote 4), and this branch has exactly three, so 3 inches is the smallest.
Reference: 2018 Uniform Plumbing Code, Table 703.2, footnote 4
A 60 degree offset has a set (offset distance) of 18 inches. What is the travel (center-to-center length of the offset pipe)? Travel = set x 1.155 for a 60 degree fitting.
Answer: 20.8 inches
For a 60 degree offset the travel is the set divided by sin 60 degrees (0.866), which is the same as set x 1.155: 18 x 1.155 = 20.8 inches. 25.5 inches comes from the 45 degree multiplier (1.414), 36 inches from the 30 degree multiplier (2.0), and 15.6 from multiplying by 0.866.
Reference: Mathematics for Plumbers and Pipefitters, General practice: offset travel = set x 1.155 (60 degree fittings)
Sources
- PSI: Hawaii Plumbers Candidate Information Bulletin (7/21/2023) (opens in a new tab)
- Hawaii DCCA Professional and Vocational Licensing (opens in a new tab)
- Hawaii Revised Statutes chapter 448E (electricians and plumbers) (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.